Installation
Instructions
(cont'd)
Temperature-Pressure
Relief Valve
AWARNING
At the time of manufacture this water heater was provid-
ed with a combination temperature-pressures relief valve
certified by a nationally recognized testing laboratory that
maintains periodic inspection of production of listed
equipment or materials, as meeting the requirements for
Relief Valves and Automatic Gas Shutoff Devices for Hot
Water Supply Systems, and the latest edition of ANSI
Z21.22 and the code requirements
of ASME. If replaced,
the valve must meet the requirements of local codes, but
not less than a combination temperature
and pressure
relief valve certified as meeting the requirements for
Relief Valves and Automatic Gas Shutoff Devices for Hot
Water Supply Systems, ANSI Z21.22 by a nationally recog-
nized testing laboratory that maintains periodic inspection
of production of listed equipment or materials.
The valve must be marked with a maximum set pressure
not to exceed the marked hydrostatic working pressure of
the water heater (150 IbsJsq.in,) and a discharge capacity
not lessthan the water beater input rate as shown on the
model rating plate, (Electric heaters - watts divided by
1000 x 3415 equal BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the use
of a temperature-pressure
relief valve complying with
ANSI Z21.22 and ASME, may require a valve model differ-
ent from the one furnished with the water beater.
Compliance with such local requirements
must be satis-
fred by the installer or end user of the water heater with a
locally prescribed temperature-pressure
relief valve
installed in the designated opening in the water heater in
place of the factory furnishedvalve.
For safe operation of the water heater, the relief valve
must not be removed from it's designated opening or
plugged.
The temperature-pressure relief valve must be installed
directly into the fitting of the water heater designatedfor
the relief valve. Position the valve downward and provide
tubing so that any discharge will exit only within 6 inches
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical
part. The discharge opening must not be blocked or
reduced in size under any circumstances. Excessivelength,
over 30 feet, or use of more than four elbows can cause
restriction and reduce the discharge capacity of the valve.
No valve or other obstruction is to be placed between the
relief valve and the tank. Do not connect tubing directly to
discharge drain unlessa 6" air gap is provided. To prevent
bodily injury, hazard to life, or property damage, the relief
valve must be allowed to discharge water in quantities
should circumstances demand. If the discharge pipe is not
connected to a drain or other suitable means, the water
flow may cause property damage.
The Discharge Pipe:
Must not be smaller in size than the outlet pipe size of
the valve, or have any reducing couplings or other
restriction.
Must not be plugged or blocked.
Must be of material listed for hot water distribution.
Must be installed so as to allow complete drainage of
beth the temperature-pressure relief valve, and the dis-
charge pipe.
Must terminate at an adequate drain.
Must not haveanywdve between the relief wdve and tank.
_,WARNING
The temperature-pressure relief valve must be manually
operated at least once a year, Caution should be taken to
ensure that (I) no one is in front of or around the outlet
of the temperature-pressure
relief valve discharge line,
and (2) the water manually discharged will not cause any
bodily injury or property damage because the water may
be extremely hot.
If efter manually operating the valve, it fails to complete-
ly reset and continues to release water, immediately,
close the cold water inlet to the water heater, follow the
draining instructions, and replace the temperature-pres.
sure relief valve with a new one.
COLD
,.,(---
SHUT-OFF
VALVE
CONDUIT
f
TEMPERATURE-
PRESSURE
_
_'RELIEF
VALVE
(Do not €_o
Ao-u,,
WARNING
"RELIEF
VALVE OPENING"
heat_
TANK
i
;"_;,
!:
JACKET
• f.
BRASS
TANK
COUpUN G
T&P REUEF
VALVEPROBE
TEMPERATURE-
MUST EXTEND
PRESSURE
INTO TANK
RELIEF VALVE
NI
,
. t
SHANK
e ff a shod _a_
(le_
Eqan 2') _un_pressgre
lelief valve _ to be irtStalled
(as_orm), a n_ole _d C<X_,_mustbeus_
• If a Io_ sl.,a_ (2' o_lor, g eOIs tobei_sta_d, dono_use_e nipf_ a_dcc_,#i_.
T__ralurlPpr_,_ure
R_dk_fValve ¢srtihlld as n_li
the t_ql_n_
Iof Relief V_Vll
ind
nmt be o_d,
po,4_d wi_ lubing, orothe_v_ _
thatdi_arge _ _,_ ody.ith_ 6 _ches !