Kenmore 8519319A Use & Care Manual page 11

He3
Table of Contents

Advertisement

Available languages

Available languages

3-wire connection:
Direct wire
Optional
3-wire connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/2in. (8.9 cm) of outer covering from end of cable. Strip
insulation back 1 in. (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground
conductor to
neutral wire.
1. Remove center terminal block screw.
2.
Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Connect appliance
ground wire and the neutral wire (white or center wire) of
power supply cord/cable under center, silver colored terminal
block screw. Tighten screw.
3. Connect the other wires to outer terminal block screws.
Tighten screws.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
!! !!
4. Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down
screw.
6. Connect a separate copper ground wire from the external
ground connector screw to an adequate ground.
1.
2.
Loosen or remove center terminal block screw.
Place the hooked end of the neutral wire (white or center wire)
of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.
1
2
4
1. External ground connector
2. Neutral grounding
wire (green/yellow)
3. Center silver-colored
terminal block screw
4. Neutral wire (white or center wire)
5. ¾in. (!.9 cm) UL-tisted strain relief
1, External ground connector
2, Neutral grounding
wire (green/yellow)
3, Neutral wire (white or center wire)
4, Grounding path determined
by a
quafified electrician
3
4
3.
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
4. Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
11

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

110. series

Table of Contents