OPERATOR'S MANUAL
6 GALLON PORTABLE AIR COMPRESSOR
H1506F
Your air compressor has been engineered and manufactured to Husky's high standard for dependability, ease of opera-
tion, and operator safety. When properly cared for, it will give you years of rugged, trouble-free performance.
WARNING:
To reduce the risk of injury, the user must read and understand the operator's manual before using
this product.
Thank you for buying a Husky product.
SAVE THIS MANUAL FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H1506F and is the answer not in the manual?

Questions and answers

Summary of Contents for Husky H1506F

  • Page 1 6 GALLON PORTABLE AIR COMPRESSOR H1506F Your air compressor has been engineered and manufactured to Husky’s high standard for dependability, ease of opera- tion, and operator safety. When properly cared for, it will give you years of rugged, trouble-free performance.
  • Page 2: Table Of Contents

    Any such additional equipment has not been examined and no implication of proper use for breath- ing air is intended or implied. If this compressor is altered in any way, existing warranties shall be voided. Husky and One World Technologies, Inc. disclaim any liabilities whatsoever for any loss, personal injury, or damage.
  • Page 3: General Safety Rules

    GENERAL SAFETY RULES n Additional safety protection will be required in some WARNING: environments. For example, the working area may include exposure to a noise level which can lead to Read and understand all instructions. Failure to fol- hearing damage. The employer and user must ensure low all instructions listed below may result in electric that any necessary hearing protection is provided and shock, fire, and/or serious personal injury.
  • Page 4 GENERAL SAFETY RULES n Never point any tool toward yourself or others. n Disconnect power supply, open drain valve to de- n Keep the exterior of the air compressor dry, clean, compress tank and allow water to drain, and allow air compressor to become cool to the touch before and free from oil and grease.
  • Page 5: Specific Safety Rules

    SPECIFIC SAFETY RULES n Always follow all safety rules recommended by n Know your power tool. Read operator’s manual the manufacturer of your air tool, in addition to all carefully. Learn its applications and limitations, as well safety rules for the air compressor. Following this as the specific potential hazards related to this tool.
  • Page 6: Symbols

    SYMBOLS Some of the following symbols may be used on this tool. Please study them and learn their meaning. Proper interpre- tation of these symbols will allow you to operate the tool better and safer. SYMBOL NAME DESIGNATION/EXPLANATION Volts Voltage Amperes Current Hertz...
  • Page 7 SYMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product. SYMBOL SIGNAL MEANING Indicates an imminently hazardous situation, which, if not avoided, will DANGER: result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, could WARNING: result in death or serious injury.
  • Page 8: Electrical

    ELECTRICAL EXTENSION CORDS SPEED AND WIRING The no-load speed of this air compressor is approximately Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the 26,000 rpm. This speed is not constant and decreases air compressor’s plug.
  • Page 9: Glossary Of Terms

    GLOSSARY OF TERMS Air Filter Pressure Switch Porous element contained within a metal or plastic hous- Automatically controls the on/off cycling of the compres- ing attached to the compressor cylinder head which sor. It stops the compressor when the cut-off pressure in removes impurity from the intake air of the compressor.
  • Page 10: Features

    FEATURES PRODUCT SPECIFICATIONS Running Horsepower..........1.5 HP Lubrication .............Oil-Free Gauges ............1.5 in. diameter Air Tank Capacity ............6 gal. Input ........ 120 V, 60 Hz, AC only, 12 Amps Air Pressure ............ 135 psi max. Air Delivery ........... 2.5 SCFM @ 90 psi Net Weight.............
  • Page 11: Assembly

    FEATURES KNOW YOUR AIR COMPRESSOR PRESSURE REGULATOR KNOB See Figure 2. Use the pressure regulator knob to adjust the amount of Before attempting to use this product, familiarize yourself air being delivered through the hose. with all operating features and safety rules. REGULATOR PRESSURE GAUGE ACCESSORY KIT The current line pressure is displayed on the regulator...
  • Page 12: Breaking In The Pump

    ASSEMBLY n Insert thread end of hose into open end of air outlet fit- AIR OUTLET FITTING ting. Use open-end wrench to tighten securely. HOSE NOTE: Be careful not to allow threads to become cross-threaded. n Attach quick coupler to open end of hose and tighten securely.
  • Page 13: Operation

    OPERATION HOSE WITH WARNING: QUICK COUPLER CHUCK ATTACHED Do not allow familiarity with tools to make you careless. Remember that a careless fraction of a second is sufficient to inflict serious injury. WARNING: 1/4 in. NPT MALE CONNECTOR Always wear safety goggles or safety glasses with side Fig.
  • Page 14: Draining The Tank

    OPERATION DRAINING THE TANK See Figure 10. To help prevent tank corrosion and keep moisture out of the air used, the tank of the compressor should be drained daily. To drain: n Rotate drain valve left to open. n Drain moisture from tank into a suitable container. NOTE: Condensate is a polluting material and should be DRAIN disposed of in compliance with local regulations.
  • Page 15: Maintenance

    When servicing, use only identical Husky replacement Use clean cloths to remove dirt, dust, oil, grease, etc. parts. Use of any other parts may create a hazard or cause product damage.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Problem Possible Cause Solution Compressor will not run Loss of power or overheating Check for proper use of extension cord No electrical power Check to be sure unit is plugged in Check fuse/breaker or motor over- load Blown shop/house fuse Replace shop/house blown fuse Shop/house breaker open Reset shop/house breaker, determin-...
  • Page 17: Warranty

    WARRANTY LIMITED WARRANTY STATEMENT necessary by normal wear or by the use of parts or accessories which are either INCOMPATIBLE WITH One World Technologies, Inc. warrants to the original THE ONE WORLD TECHNOLOGIES, INC. product or retail purchaser that this One World Technologies, Inc. adversely affect its operation, performance, or durability.
  • Page 18: Parts Ordering / Service

    OPERATOR’S MANUAL 6 GALLON PORTABLE AIR COMPRESSOR H1506F • SERVICE Now that you have purchased your tool, should a need ever exist for repair parts or service, simply contact your nearest Authorized Service Center. Be sure to provide all pertinent facts when you call or visit. Please call 1-866-340-3912 for your nearest Authorized Service Center.