INSTALLATION, AND MAINTENANCE MANUAL FOR GAS FIRED, WALL-HUNG BOILERS RSF 20 E • RSF 24 E • RSF 30 E models TYPE C ROOM SEALED SEDBUK BAND D 0694 TA05A27.A0504 Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH...
INDEX PRODUCT CONFORMITY page INSTALLATION INSTRUCTIONS AND WARNINGS page TECHNICAL DATA page OVERALL DIMENSIONS - EXHAUST FLUE SYSTEM page GENERAL INSTALLATION REQUIREMENTS page BOILER INSTALLATION page ELECTRICAL CONNECTIONS page BOILER CONTROL PANEL page STARTING UP THE BOILER FOR THE FIRST TIME page MULTIGAS OPERATION page...
Page 4
• GAS DIRECTIVE 92/42/ECC requirements for new hot-water boilers fired with liquid or gaseous fuels All RADIANT boilers are constructed according to UNI - CIG (EC) norms. The materials used, such as copper, brass, and stainless steel form a compact, homogeneous, highly functional unit that is easy to install and simple to operate. The wall-mounted boiler is equipped with all of the approved accessories required to make it a true, independent heating plant for home heating and for the production of hot water for domestic needs.
Page 5
Installation Manual INSTALLATION INSTRUCTIONS - WARNINGS THIS INSTALLATION, USE, AND MAINTENANCE MANUAL IS AN ESSENTIAL AND INTEGRAL PART OF THE PRODUCT, AND MUST ALWAYS BE KEPT NEAR THE DEVICE. THE WARNINGS CONTAINED IN THIS SECTION ARE ADDRESSED BOTH TO THE USER AND TO INSTALLATION AND MAINTENANCE PERSONNEL.
Installation Manual SYSTEMS WITH THERMOSTATS A by-pass must be installed in heating systems with radiators thermostats. As required by current norms, these devices must be installed by qualified personnel only, who must respect norms UNI-CIG 7129 and 7131 and revisions, fire department regulations, and requirements of the local gas company. Before installing the boiler, make sure that the water and heating systems are compatible with its output.
Page 7
Type C devices are devices in which the combustion circuit (air intake, combustion chamber, exchanger, combustion exhaust) is sealed off from the place where they are installed. Coaxial vertical C52 Double Coaxial horizontal MODELS RSF 20 E RSF 24 E RSF 30 E Maximum rated input kcal/h 22016 25628 29670 25.60...
To insert a bend, reduce total flue length by 1.5 m. NOTE: USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS, FLUE ACCESSORIES AND FLUE DIAPHRAGMS ONLY. APPROVED RADIANT FLUE DIAPHRAGMS AND ADJUSTMENT TABLES ARE SUPPLIED WITH RADIANT ORIGINAL FLUE. DOMESTIC HOT WATER WITH STORAGE CYLINDER – TA05A027.A0504...
Page 9
1.5 m. 65.5 55.5 OTE: USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS, FLUE ACCESSORIES AND FLUE DIAPHRAGMS ONLY. APPROVED RADIANT FLUE DIAPHRAGMS AND ADJUSTMENT TABLES ARE SUPPLIED WITH RADIANT ORIGINAL FLUE KIT SYSTEMS. DOMESTIC HOT WATER WITH STORAGE CYLINDER – TA05A027.A0504...
Page 10
1.5 m. NOTE: USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS, FLUE ACCESSORIES AND FLUE DIAPHRAGMS ONLY. APPROVED RADIANT FLUE DIAPHRAGMS AND ADJUSTMENT TABLES ARE SUPPLIED WITH RADIANT ORIGINAL FLUE KIT SYSTEMS. 55.5 65.5 DOMESTIC HOT WATER WITH STORAGE CYLINDER – TA05A027.A0504...
Installation Manual GENERAL INSTALLATION REQUIREMENTS GAS SAFETY It is the law that all gas appliances are installed by a CORGI registered installer (you can check this by contacting corgi on 01256.372200) in accordance with the regulations listed below. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to ensure that the law is complied with.
Page 12
Installation Manual FLUE POSITION IMPORTANT: THE FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS CONTAINED IN BS 5440:1. The boiler MUST be installed so that the terminal is exposed to the external air. It is important that the position of the terminal allows free passage of air across it at all times. If the terminal discharges into a pathway or passageway check that combustion products will not cause nuisance and that the terminal will not obstruct the passageway.
Installation Manual BOILER INSTALLATION MINIMUM DISTANCES FOR FIXING TO WALL KIT A MOD. 1 To allow access in the boiler KIT H MOD. 2 for maintenance operations, MOD. 2 the minimum distances shown below must be respected (fig. MOD. 1 CON STAFFA MOD.
Page 14
RSF 24 E ANTI-FREEZE SYSTEM ANTI-FROST SYSTEM Radiant boilers are equipped with an Anti-Freeze system which comes into operation when the temperature falls to 5° C (Heating sensor) and 4° C (Hot water sensor) and protects the boiler down to –10°C external temperature.
Installation Manual ELECTRICAL CONNECTIONS For qualified personell only: the boiler works with 230 V 50 Hz AC current and has maximum input of 170 W. Connection to the electrical mains must be performed with a device having an omnipolar opening of at least 3 mm. Make sure the live and neutral connections conform to the diagram.
Page 16
Installation Manual CONTROL PANEL LEGEND (see fig. 1) ON / OFF POWER BUTTON HEATING TEMPERATURE ADJUSTMENT KNOB DOMESTIC HOT WATER TEMPERATURE ADJUSTMENT KNOB OUTSIDE TEMPERATURE DISPLAY PAD (ONLY WITH OPTIONAL OUTSIDE TEMPERATURE SENSOR FITTED) CHIMNEY-SWEEPER SELECTION PAD/PARAMETER SETTING SERVICE PAD MODE SELECTION PAD (SUMMER ONLY / WINTER ONLY / SUMMER AND WINTER) MAIN EXTERNAL TERMINAL BLOCK (POWER...
Page 17
Installation Manual • check the pressure in the system: if this has gone down, comes on restore AIR VENT VALVE CAP pressure; AIR VENT VALVE • close the tap on the filling loop once this operation is completed; CIRCULATING PUMP Starting up the boiler PUMP CAP •...
Page 18
BURNER M ANIFOLD new one pplied in the 11 RAMP GAS BURNE R – mod. RSF 20 E conversion kit. 13 RAMP GAS BURNER – mod. RSF 24 E 17 RAMP GAS BURNER – mod. RSF 30 E INJECTORS 10. IGNITION ELEC TRODES 11.
Page 19
Installation Manual GAS DATA TABLE models: RSF 20 E NATURAL GAS G 20 LIQUID BUTAN GAS G 30 LIQUID PROPANE GAS G 31 Lower Wobbe index (15°C; 1013 mbar) 45.67 80.58 70.69 MJ/Nm Rated feed pressure mbar Minimum feed pressure mbar Main burner: 11 Jets - Ø...
Installation Manual WIRING DIAGRAMS PRINTED CIRCUIT BOARD CVI-M SM20015 (cod. 76655LA) DISPLAY DIGITAL BOARD 2000 SKO6206 (COD. 76654LA) - LINE - NEUTRAL - AIR PRESSURE SWITCH - WATER PRESSURE SWITCH - ELECTRONIC FLOWSWITCH - MAIN SWITCH - D.H. WATER SENSOR ELECTRONIC IGNITION BOARD - HEATING SENSOR 1,5bar...
Page 23
Installation Manual WIRING DIAGRAM FOR REMOTE CONTROL INSTALLATION (no zone valves) Fig. 3 Interfaccia grey orange Fig. 2 P.B.C. INTERFACE REMOTE Fig. 4 TA TA EXTERNAL SENSOR M1 1 REMOTO Fig. 5 Fig. 1 Fit the interface (fig. 2) on the circuit board (fig. 1) into the holes A and B provided (see fig. 1). Connect plug M1 on the interface circuit board (fig.
Installation Manual MAINTENANCE Casing removing • pull and remove the boiler front casing; • undo the 4 bottom screws that fix the side casing to the lower boiler grid (2 screws each side panel); • undo the casing fixing plate screw on the left side of the room seal chamber; •...
Page 25
Installation Manual Fault Description Possible Cause Solution Code BOILER FAILS TO FIRE No gas / gas turned off Check gas supply / open the gas cock Ignition electrode damaged or earthed Replace it Electronic ignition board S4565QM faulty Replace it Gas valve faulty Replace it Flame lock-out...
Page 26
Installation Manual SPARE PARTS SHORT LIST CODE DESCRIPTION RSF 20 E RSF 24 E RSF 30 E 20040LA PLATE EXCHANGER 16 P 561222 √ 20046LA PLATE EXCHANGER 24 P 3017B1902406 √ √ 20047LA PLATE EXCHANGER 20 P 17B1902006 21001LA GAS BURNER 13 RAMP 1.25 NATURAL GAS 401.1207.02 √...
Page 27
PIPE D.14 MULTIPLEX-PUMP MANIFOLD 86014LA WATER PRESSURE GAUGE M3A-ABS 400-4 PB120417 20040LA PLATE EXCHANGER 16 P. 561222 – RSF 20 E 20046LA PLATE EXCHANGER 24 P. 3017B1902406 – RSF 30 E 20047LA PLATE EXCHANGER 20 P. 17B1902006 – RSF 24 E 43002LA WASHER D.18.5x10.2x2 1/2"...
Page 28