Summary of Contents for Rofer & Rodi Estufas Rofer
Page 1
ESTUFAS ROFER – MANUAL DE INSTALACIÓN Y USO CHIMENEAS ROFER & RODI...
Page 2
ROFER STOVES – MANUAL OF INSTALLATION AND USE Contents: Warning for the installer and user: CE Brand 1.- GENERAL DESCRIPTION 2.- INSTALLATION INSTRUCTIONS 2.1.- Assembly of the stove 2.2.- Site of installation 2.3.- Assembly of the smoke ducts 3.- INSTRUCTIONS FOR USE 3.1.- Fuel and Lighting 3.2.- Cleaning and Maintenance 4.
Page 3
ROFER STOVES – MANUAL OF INSTALLATION AND USE UNE-EN 13240 Manufacturer: Rofer Axarquía S.L. Family / Models ROFER stoves. Models Hispalis, Tarsis, Iliberis, Italica, Malaka, Abdera Heating power 11.5 kW Energetic Performance Minimum distance to adjacent 1.2 m fuel materials Carbon Monoxide emission at 0.6% 13% of Oxygen...
ROFER STOVES – MANUAL OF INSTALLATION AND USE 1.- GENERAL DESCRIPTION • The models of ROFER stoves offer greater performance and safety thanks to their careful design and the use of the highest quality components. The device conforms to regulations UNE EN-13240.
ROFER STOVES – MANUAL OF INSTALLATION AND USE 2.- INSTALLATION INSTRUCTIONS 2.1.- Assembly of the stove • The stove, ducts and hood should not be installed next to coatings, wood parquet or other potentially inflammable elements which should be kept at a safety distance of 1.2 m from the device.
Page 6
ROFER STOVES – MANUAL OF INSTALLATION AND USE 2.3.- Assembly of the smoke ducts A metallic pipe of a specified diameter must be used for the evacuation of • smoke through the whole length of the chimney draught. In accordance with current regulations, we recommend the use of a stainless or vitrified steel pipe.
Page 7
ROFER STOVES – MANUAL OF INSTALLATION AND USE • The smoke duct and the hood of each device should be individual. Do not connect 2 or more heating devices to the same smoke duct. • In order to prevent the soot accumulated in the chimney draught catching fire, with its consequent fire hazard, the draught should be cleaned at periodic intervals using mechanical means carried out by qualified technical staff.
Page 8
ROFER STOVES – MANUAL OF INSTALLATION AND USE • During the first lighting some smoke may appear as a result of the drying of the protective coat of heat-resistant paint applied to the stove. For this reason we recommend that you ventilate the premises until this smoke disappears. Draught Adjustment (optional) •...
ROFER STOVES – MANUAL OF INSTALLATION AND USE Diagram and Connection to the electricity mains (only in models fitted with turbines) • During the normal use of the device and whilst it is lighted, you are advised not to disconnect it from the electrical mains. However, a permanent connection must not be made in the fuse box but preferably by means of an approved model of plug with an earth wire which, when required, allows the user to disconnect it.
ROFER STOVES – MANUAL OF INSTALLATION AND USE 4. TECHNICAL DATA 4.1.- General Characteristics • The ROFER stove is a device that complies with obligatory regulations UNE EN-13240. Normal heat output: 11.5 Kw Performance: 0.6% CO concentration at 13% oxygen Smoke flow 15 g/s Optimum draught suction:...
Page 11
ROFER STOVES – MANUAL OF INSTALLATION AND USE ROFER & RODI FIREPLACES...
Page 12
ROFER STOVES – MANUAL OF INSTALLATION AND USE ROFER & RODI FIREPLACES...
Page 13
ROFER STOVES – MANUAL OF INSTALLATION AND USE ROFER & RODI FIREPLACES...
Page 14
ROFER STOVES – MANUAL OF INSTALLATION AND USE ROFER & RODI FIREPLACES...
ROFER STOVES – MANUAL OF INSTALLATION AND USE 4.3.- Spare Parts • To order spare parts indicate the serial number and year of manufacture figuring on the plate attached to the device or on the warranty card. Only original spare parts must be used.
Page 16
ROFER STOVES – MANUAL OF INSTALLATION AND USE 4.4.- Probable causes of failure or irregular functioning • The device you have purchased is a high performance fireplace of guaranteed quality. Nevertheless, certain extreme climate conditions such as strong winds, hail storms or risks of freezing temperatures, may cause the chimney draught to be inadequate.
Page 17
ROFER STOVES – MANUAL OF INSTALLATION AND USE Table 2 Irregular function Probable cause Course of action The device does not The wood is of a poor Use only the types and sizes of firewood generate sufficient quality recommended in the user’s manual. heat.
ROFER STOVES – MANUAL OF INSTALLATION AND USE CE Declaration of compliance The manufacturer hereby Certifies that the fireplace models listed below meet all the requirements of the EU Directive governing construction products (89/106/EEC) and comply with regulations UNE-EN 13240: 2002 “Stoves using solid fuel-Testing requirements and methods”, modified by UNE-EN 13240:2002 / A2:2005, UNE-EN 13240:2002 / AC:2006, UNE-EN 13240:2002 / A2:2005 / AC:2006...
Page 19
ROFER STOVES – MANUAL OF INSTALLATION AND USE ROFER & RODI FIREPLACES...
Need help?
Do you have a question about the Estufas Rofer and is the answer not in the manual?
Questions and answers
How do I take the door off the wood burner