The voltage value mentioned on the adapter may not be exceeded. If you connect EasyGate to another power supply, make sure that the voltage value is in the acceptable range. When your EasyGate comes to the end of its operational life, dispose of it in accordance with applicable regulations.
Page 3
The manufacturer continuously meets customer requirements by improving the firmware. For the latest EasyGate processor firmware, programming tool and User Manual see www.2n.cz. For a detailed description of the EasyGate firmware upgrade refer to the section devoted to the PC programming tool.
Warranty certificate 1 pc Notes: 1) The delivery includes an antenna to be connected directly to the EasyGate SMA connector. An antenna with a cable can be ordered separately for places with a poor GSM signal. 2) You will find the electronic format of the User Manual on a CD-ROM.
ENDING AND ECEIVING 7.6. COM T ............13 OMBINATION OF RAFFIC WITH OICE ALLS 7.7. AT C ..................13 IST OF UPPORTED OMMANDS EASYGATE PARAMETER PROGRAMMING ............14 8.1................14 ELEPHONE INE BASED ROGRAMMING 8.2....................15 BASED ROGRAMMING 8.3......................18 ARAMETER ABLES TROUBLESHOOTING ....................25 10.
• You can send an SMS to a pre-programmed number using the SMS sending input. 1.2. Advantages of EasyGate Use • Call cost cutting – by forwarding GSM calls to EasyGate you save a lot on PSTN – GSM calls.
• It is impossible to operate EasyGate on sites exposed to direct solar radiation or near heat sources. • EasyGate is designed for indoor use. It may not be exposed to rain, flowing water, condensed moisture, fog, etc. • EasyGate may not be exposed to aggressive gas, acid vapours, solvents, etc.
Make sure that the GSM provider’s SIM card is compatible with the GSM network supported by your EasyGate version. Open the SIM card holder on EasyGate’s backside, insert the SIM card and close it. Select the required GSM provider and SIM card services, such as call forwarding, call barring, preferred networks, SMS service centre, etc.
2.5. Telephone Line Connection 2.5.1. PBX Connection Connect EasyGate to a free CO line of your PBX. Configure your PBX in such a manner that GSM outgoing calls are routed to EasyGate. EasyGate is equipped with the FSK-based CLIP function. If your PBX is able to process the caller’s ID, you are advised to enable this function.
2.8. PC Connection You have got a serial cable for PC connection. It is a modem cable where all of the 9 pins are 1:1 interconnected – in case you wanted to use another, longer cable. Make sure that a longer cable works properly to avoid errors at high transmission rates.
The GSM gateway sends tones to the telephone line to indicate the line status. The tone frequency is 425 Hz. Dial tone: • EasyGate is registered to GSM network and ready to receive dialing. Ringing tone: • The called subscriber's telephone is ringing.
Page 12
The called subscriber has hung up (disconnection). Dialing end signaling: • Dialing reception has been terminated. Connection is being established. PIN tone: • Enter the PIN code. • This tone is transmitted upon power up if the PIN has to be entered manually. PUK tone: •...
4.3. Automatic PIN Entering You need not enter the PIN upon power up if it is stored in EasyGate – it is entered automatically. This function is convenient in case of power failure; EasyGate is operable in a short time after power recovery without any intervention by the operating staff.
5 s (programmable parameter). The number is evaluated as complete and transmitted to the GSM network after this timeout. 3. A short delay follows the last-dialed digit for EasyGate to await further dialing. Then, the dialing end is signaled and connection is established.
Caution! Do not use in life-supporting or property-protection applications because of the character of SMS service and EasyGate. The manufacturer shall not be liable for health and property damage incurred as a result of SMS sending failure.
The program is designed for EasyGate parameter programming. It can read configuration data from the memory and store them in EasyGate. Moreover, all parameters can be saved in your PC file for backup or saving into another EasyGate system. The EasyGate PCManager contains an easy monitoring tool too. With this tool you can identify the GSM provider’s name, signal strength, GSM module, SIM, and so on...
7.3. FAX Transmission - PC-FAX EasyGate allows fax transmissions from your PC. However, do not confuse the PC- Fax service with a standard fax service – no fax machine can be connected to the telephone line! But the PC-Fax can establish connection with a standard fax machine and transmit documents.
Outgoing and incoming calls can be made during GPRS connection. The GPRS connection remains active during the whole call but no data can be transmitted (EasyGate is a GPRS terminal of class B). Once the call is terminated, data transmission is recovered immediately.
8. EasyGate Parameter Programming All EasyGate parameters have such default values that meet most users’ demands and need not be changed. To change EasyGate parameters in spite of that, you can either: • Use a PC with the PCManager installed. All functions supported by EasyGate can be set using the PC.
EasyGate data uploading and storing, including firmware upgrade, are executed in a special mode, in which EasyGate waits for about 3s after power up (all LEDs are on). If instructed so by the PCManager during this timeout, EasyGate remains in this mode as long as it is necessary.
Page 21
They are not saved in a PC file for security reasons. If you load a PC file into the PCManager and then into EasyGate, the PIN and service password should not change unless you change them manually before saving.
Page 22
• The GSM provider's name and signal strength received by EasyGate - this information helps you find the optimum signal location (the information is updated in 10s intervals); • The EasyGate line status – standby, outgoing call, incoming call including telephone number.
(initialization) value. 8.3.1. Telephone Line Parameters Type of dialing Function No.: Select the dialing type to be received by EasyGate from the PBX or telephone set. EasyGate accepts only the selected type of dialing, ignoring the others. Setting options: DTMF -EasyGate receives tone dialing only.
Page 24
BabyCall timeout [s] Function No.: Time between line Off-Hook and automatic call beginning (if enabled). During this timeout EasyGate waits for dialing that cancels the automatic call. You can make standard call if the BabyCall function is enabled. Setting options: 0-15 s...
Page 25
• Modify the number to be dialed by removing and/or adding digits. Every table line includes a prefix (of variable length) plus parameters that define EasyGate's behavior in case the beginning of the dialed number matches this prefix. The table can contain up to 20 different prefixes.
Page 26
Routing table enable Function No.: Enable the use of the routing table with this parameter. Disabling this parameter you put the table out of use. Setting options: YES/NO Default setting: NO Prefix Function No.: A prefix identifying the call type (GSM, trunk call, free call, etc.). "Other numbers" line is used for calls with prefixes that are not included in the table.
Page 27
GSM operator lock Function No.: Provider blocking is set by manufacturer in EasyGate. If EasyGate is blocked to a GSM provider, no other GSM provider's SIM card can be used. If an unacceptable SIM card is used, the GSM modules does not registered to GSM and the GSM network LED flashes quickly on the EasyGate panel.
Page 28
Roaming enable/disable Function No.: You can make EasyGate work even if it is registered to a foreign GSM network. Setting options: -Disable -The GSM module logs out of a foreign network and attempts to register again in within 5 minutes.
Page 29
PIN - value Function No.: Fill in the PIN value for automatic PIN entering upon EasyGate power up. It is applied only if the SIM card is PIN secured. If the given PIN fails to match the SIM, it is deleted automatically. If entered via a telephone line upon EasyGate start, the PIN is stored automatically.
• EasyGate is in the special PCManager-based programming mode - exit the PCManager to reset EasyGate. • Try to switch EasyGate off and on, the LEDs should go off in 3s and signal the status of EasyGate. EasyGate does not register to GSM •...
- Circuit Switched Data • - PC serial port • DTMF - Dual Tone Multifrequency - tone dialing • - EasyGate • - Frequency Shift Keying • - an interface electrically identical with a standard telephone (opposite side = FXS interface) •...