Tanita MC-780MA Instruction Manual

Tanita MC-780MA Instruction Manual

Body composition analyzer
Hide thumbs Also See for MC-780MA:

Advertisement

BODY COMPOSITION ANALYZER
<Usage Conditions>
Temperature
: 5°C – 35°C
Relative Humidity : 30% – 80%
(without condensation)
Maximum Altitude : 2,000m ASL
: 86kPa - 106kPa
Pressure
Please read this Instruction Manual carefully and keep it for
future reference.
MC-780MA

Instruction Manual

<Storage Conditions>
Temperature
RelativeHumidity : 10% – 90% (without condensation)
To avoid malfunctions, avoid storing the equipment in a place with direct sunlight,
significant temperature changes, a risk of dampness, a large amount of dust or a
risk of vibration or impact, or in the vicinity of flames.
: -10°C – 50°C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC-780MA and is the answer not in the manual?

Questions and answers

Summary of Contents for Tanita MC-780MA

  • Page 1: Instruction Manual

    BODY COMPOSITION ANALYZER MC-780MA Instruction Manual <Usage Conditions> <Storage Conditions> Temperature : 5°C – 35°C Temperature : -10°C – 50°C Relative Humidity : 30% – 80% RelativeHumidity : 10% – 90% (without condensation) (without condensation) To avoid malfunctions, avoid storing the equipment in a place with direct sunlight,...
  • Page 2: Intended Use

    Intended Use •This equipment can be used in the screening of certain adult diseases and conditions related to body weight and composition. •The equipment can be used in the monitoring and prevention of conditions caused by excessive deposits of fatty tissue such as diabetes, hyperlipidemia, cholelithiasis (gallstones) and fatty liver.
  • Page 3: Table Of Contents

    Contents Before Use For Your Safety Part Names & Connection Preparation Power Supply Settings How to Use Taking a Measurement Body Composition Mode Measurement Results Scale Mode Weight Lock Mode Output and Storage of Measurement Results If Necessary Troubleshooting Specifications...
  • Page 4: For Your Safety

    For Your Safety This section explains precautionary measures to be taken to avoid injury to the users of this device and others, and to prevent damage to property. Please familiarise yourself with this information to ensure safe operation of this equipment. Warning Failure to follow instructions highlighted with this mark could result in death or severe injury.
  • Page 5 Caution Keep away from water. Avoid using on subjects with metal allergies. Allergic reactions may be caused by the stainless steel used in the electrodes of this device. Do not jump on the equipment. Do not lean on the equipment. Do not use this equipment near other products that emit electromagnetic waves.
  • Page 6 For Accurate Measurements Avoid measuring after strenuous exercise. This may cause inaccurate measurements. Please take measurements after sufficient rest. Avoid measuring after excessive food or fluid intake or when dehydrated. This may cause inaccurate measurements. For greater accuracy, avoid using directly after waking up.
  • Page 7 Scheduled Maintenance TANITA recommends that each facility conduct periodic checks of each unit. 1. Check the following at least daily: • That the unit is on a stable and level surface • Date and time settings 2. Visually inspect the following at least weekly: •...
  • Page 8: Part Names & Connection

    Part names & Connection procedure Symbols and their Meanings Positive polarity Serial interface Conformity with Medical Device Directive Direct current 0123 93/42/EEC Grip Alternating current Class II Equipment Control Unit Type BF applied part Input, Output - Grips and platform WEEE - Waste Electrical Date of manufacture and Electronic...
  • Page 9 Display and Keys MC-780 III Max 270kg Min 2kg e=0.1kg T = -10kg Standard Athletic Male Female 5 - 99 Setting Height 90.0 - 249.9cm Enter Meanings of the LED Indicators and Keys Display Body Fat (percentage and mass) Turn ON / OFF the power Not measured value but calculated value Display Body Muscle (percentage and mass) Not measured value but calculated value...
  • Page 10: Preparation

    Preparation Setting up the main unit Platform / Control Box / Accessories Instruction manual (This manual) Assembly guide Slit cover Screw (2 items) Base slit cover Control unit cover Screw driver AC cord AC Adapter USB B mini cable...
  • Page 11 Assembly...
  • Page 12 Preparation Setting up the mainunit Assembly (continued)
  • Page 13 Assembly (continued)
  • Page 14: Power Supply

    Power Supply Turning the main power ON/OFF Turning the main power ON. Press the key to turn on the power. The initial screen is displayed. Turning the main power OFF. Press the key to turn the power off. Emergency Shut Down Keep the area around the plug socket clear during operation of the equipment in case of an emergency.
  • Page 15: Settings

    Settings Press the key to change the Setting mode. The setting screen is displayed. Note •The key cannot be used when the scale is measuring weight or impedance. Setting Select the setting item from the list below. Enter numerical values and Press the key.
  • Page 16 Settings (continued) Select the Measurement Mode Select the measurement mode by pressing the key. The measurement mode is switched Body Composition Mode in the following order when the key is pressed: MC-780 III Max 300kg Min 2kg e=0.1kg T = -10kg Standard Athletic Female...
  • Page 17: Taking A Measurement

    Taking a Measurement Body Composition Mode Enter the preset tare value (clothes weight) Turn the power on, and check that the " " mark is displayed. Enter the preset tare value (clothes weight) The tare value range is 0.0 - 10.0kg Measure body weight Wait until "...
  • Page 18 Taking a Measurement (continued) Body Composition Mode Select gender Male Female Enter age Standard Athletic Male Female 5 - 99 Setting Height 90.0 - 249.9cm Enter The age range : 5 - 99 Enter height Height Standard Athletic Male Female 5 - 99 The height range : 90.0 - 249.9 cm Setting...
  • Page 19: Measurement Results

    Measurement Results ( Body Composition Mode ) Output Measurement Results (Body Composition Mode) The measurement results are displayed on the LCD after measurement is completed. The results are output to the PC immediately after measurement is completed. Press the key to select the measurement display. The measurement display is switched in the following order by pressing the key.
  • Page 20 Taking a Measurement (continued) Measurement Results ( Body Composition Mode ) Body water Body weight (kg) Body water % Body water (kg) Body water mark Visceral fat rating Body weight (kg) Visceral fat rating VFR mark Basal metabolic rate Body weight (kg) BMR (kJ) BMR (kcal) BMR mark...
  • Page 21: Scale Mode

    Scale Mode The " " mark is displayed when the scale mode is selected. Enter the ID number If the ID number function is set to OFF, the scale starts measuring your weight immediately. Enter the ID number. The ID number range is from 0 to 9999999999999999. Press to enter tare value (clothes weight).
  • Page 22: Weight Lock Mode

    Taking a Measurement (continued) Weight Lock Mode The " " mark and " " are displayed when the weight lock mode is selected. Enter the preset tare value (clothes weight) The " " is displayed after the scale mode is selected. Enter the preset tare value (clothes weight) The tare value range is 0.0 - 10.0kg.
  • Page 23: Output And Storage Of Measurement Results

    Output and Storage of Measurement Results Data Output Outputting measurement results via the USB port The results are output to the PC immediately after measurement is completed. Data is output in CSV format. Data Storage Data storage of measurement results The results are saved to the SD card immedi- ately after measurement is completed.
  • Page 24 - People who are professional athletes. Target Body Fat •Before you start a weight management program and set the appropriate personal body fat %, please consult your doctor. Tanita is not responsible for setting the appropriate target body fat % for specific individuals. Attention •Posture when measuring...
  • Page 25: Troubleshooting

    Troubleshooting Please check the following before requesting repair. Problem Solution •Hold the handgrips and electrodes firmly with fingers and palms. •Stand barefoot on the platform for Error with measurement. impedance •If the soles of the feet are dry, use the included measurement dropper to apply about 0.5 ml of water before measurement.
  • Page 26: Specifications

    Specifications MC-780MA Model Number MDD: CLASS IIa Accuracy Grade NAWI: CLASS III Power Source 100 - 240V AC 18VA Electric Current Range Multi-Frequency 8 Electrode Measurement System 5kHz/50kHz/250kHz Measurement Frequency Up to 90µA Measurement Current Impedance Electrode Materials Feet: Stainless steel/Handgrips: plated...
  • Page 27 Clothes Weight 0 - 10.0kg (0.1kg increments) Serial No. Up to 16 digits Female/Male Gender Input Standard/Athletic* Body Type items 5 - 99 years Height 90.0 - 249.9cm (0.1cm increments) Target Body fat % 4 - 55% 1% increments ) 16 digits Gender Female/Male...
  • Page 28 <EU representative> Hoogoorddreef 56-E, 1101 BE Amsterdam, The Netherlands Tel: +31-20-560-2970 Fax: +31-20-560-2988 http://www.tanita.eu 1-14-2, Maeno-cho, Itabashi-ku, Tokyo, Japan Tel: +81 (0) 3-3968-7048 Fax: +81 (0) 3-3967-3766 http://www.tanita.co.jp 2625 South Clearbrook Drive, Unit 301-303,Wing On Plaza, 3/F., 62 Mody Rord, Arlington Heights, Illinois 60005, U.S.A.

Table of Contents