Dell PowerEdge M820 Owner's Manual page 132

Hide thumbs Also See for PowerEdge M820:
Table of Contents

Advertisement

Error Code
Message Information
SEC0043
Message
LCD Message
Details
Action
SEC0044
Message
LCD Message
Details
Action
SEC0600
Message
Details
Action
SEC0602
Message
Details
Action
SEC0604
Message
Details
Action
SEC0606
Message
Details
Action
132
BIOS Authenticated Code Module detected an Intel Trusted
Execution Technology (TXT) error during POST.
BIOS detected a TXT error during POST. Check system
configuration.
TXT Post failure. System configuration may have changed.
Check system hardware inventory and software
configuration.
SINIT Authenticated Code Module detected an Intel Trusted
Execution Technology (TXT) error at boot.
SINIT detected a TXT error at boot. Check system
configuration.
TXT initialization failure. System configuration may have
changed.
Check system hardware inventory and software
configuration.
A secure mode violation detected.
This may apply to a physical or remote access attempt.
Check system logs for intrusion attempts, and ensure strong
password policies.
User password violation detected.
This may apply to a physical or remote access attempt.
Check system logs for intrusion attempts, and ensure strong
password policies.
A setup password violation detected.
This may apply to a physical or remote access attempt.
Check system logs for intrusion attempts, and ensure strong
password policies.
The network boot password violation detected.
This may apply to a physical or remote access attempt.
Check system logs for intrusion attempts, and ensure strong
password policies.

Advertisement

Table of Contents
loading