Scout Camera SG560DF series
4.1.7 Set Video Length
This parameter is effective and can be adjusted only when the device in the video
mode for the ON mode. Its value extends from 1 to 60 seconds with a step of one
second. The default value is 10 seconds. Press "◄" and "►" to decreases or increases
the value by 1 second.
The following shows how to set video length to 15 Seconds provided that the
previous value is 1 Seconds:
a) Press MENU to display the setting menu.
b) Press "▲" or "▼" to select Video Length.
c) Press "►" to increase to 15 Seconds.
d) Press OK to save the current setting and the option will be un-highlighted.
Press MENU to exit.
4.1.8 Set PIR Sensitivity
This parameter defines the sensitivity of the PIR. There are three parameters:
High, Normal and Low. The default value is "Normal". The higher degree indicates
that the
is more easily to be triggered by motion, taking more pictures or
Camera
recording more videos. It is recommended to use high sensitivity degree in room or
environment with little interference, and to use lower sensitivity for outdoor or
environment with lots of interference like hot wind, smoke, near window etc.
Furthermore, the sensitivity of the PIR is strongly related to the temperature. Higher
temperature leads to lower sensitivity. Therefore it is suggested to set a higher
sensitivity for high temperature environment.
The following shows how to set PIR sensitivity as Low provided that the
previous option is Normal.
a) Press MENU to display the setting menu.
b) Press "▲" or "▼" to select Sensitivity.
Press "►" to select Low.
c)
Press OK to save the current setting and the option will be un-highlighted.
d)
Press MENU to return to info display.
4.1.9 Set PIR Triggering Interval
This parameter means that how long the PIR (Passive Infrared motion sensor)
will be disabled after each triggering in ON mode. During this time the PIR of the
device will not react to the motion of human (or animals). The minimum interval is 0
second, it means the PIR works all the time. The maximum interval is 1 hour. It
means the PIR will be disabled for 1 hour after each triggering. The default value is
1 minute. Press "◄" and "►" to decreases or increases the value .
The following shows how to set triggering interval time to 5 Minutes provided
that the previous value is 1 Minute.
a) Press MENU to display the setting menu.
b) Press "▲" or "▼" to select PIR Interval.
c) Press "►" to decrease or increase to 5 Minutes.
d) Press OK to save the current setting and the option will be un-highlighted.
Press MENU to cancel setting and return to info display.