HOW TO.....
3.1
HOW TO TOP-UP THE SYSTEM PRESSURE (fig. 2)
The system pressure must be checked periodi-
cally to ensure the correct operation of the boiler.
The needle on the gauge should be reading be-
tween 1 and 1.5 BAR when the boiler is in an off
position and has cooled to room temperature. If
the pressure requires 'topping-up' use the follow-
ing instructions as a guide.
Locate the filling valve connections (below the
●
boiler).
Attach the filling loop to both connections.
●
Open the isolating valve (Left) slowly.
●
Move the filling valve (Right) slowly to the fill
●
position (fig. 3) until you hear water entering the
system.
Move the filling valve back to its normal posi-
●
tion (fig. 3) when the pressure gauge (on the
boiler) reads between 1 and 1.5 BAR.
Close the isolating valve
●
Remove the filling loop from the connections.
●
3.2
HOW TO RESET THE APPLIANCE
When the LED status indicator is flashing red,
the appliance will require to be reset manually.
Using the mode selector switch, turn it to the OFF/
RESET position, then turn it back to the 'hot wa-
ter only' or 'heating & hot water' position (see also
3.3).
Allow a period of two minutes to elapse before
turning the mode switch to the reset position.
IMPORTANT
If the appliance requires to be reset frequently, it
may be indicative of a fault, please contact your
installer or Vokera Customer Services for further
advice.
3.3
DIAGNOSTIC FAULT CODES
Display shows
01
Burner has failed to ignite.
Ensure gas meter is turned on.
Wait two minutes before resetting.
If problem persists call engineer.
02
Boiler has over-heated, wait 5 minutes
for boiler to cool. Reset boiler.
If problem persists call engineer.
03
04
Low water pressure. Ensure pressure
gauge is above 0.5 bar (see 3.1).
05
Communication fault (RC05 only)
06
07
08
Linea
Action required
Flue problem.
Call engineer
Reset boiler.
call engineer.
Boiler fault.
Call engineer.
Boiler fault.
Call engineer.
Burner over-heat.
Call engineer
3.4
HOW TO SHUT DOWN THE SYSTEM FOR
SHORT PERIODS
The system and boiler can be shut down for short
periods by simply turning the time clock or boiler
control to the off position (see the instructions sup-
plied). It is also advisable to turn off the main
water supply to the house.
3.5
HOW TO SHUT DOWN THE SYSTEM FOR LONG
PERIODS
If the house is to be left unoccupied for any length
of time – especially during the winter – the sys-
tem should be thoroughly drained of all water. The
gas, water, and electricity supply to the house
should also be turned off. For more detailed ad-
vice contact your installer.
3.6
HOW TO CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp
cloth. Do not use any scourers or abrasive clean-
ers.