We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Extraflame S. p. A. enGLiSH ..............................................
Extraflame s.p.a. cannot be held responsible for the failure to comply with such precautions. After removing the packaging, ensure that the content is intact and complete. If not so, contact the dealer where the appliance was purchased.
eNgliSH Safety deviceS in which the appliance has been installed. teRMS aNd defiNitiONS Safety deviceS aeration: Air renewal is required both for the disposal of Key: * = present, - = not present the combustion products, and to prevent mixtures with a hazardous content of non-combusted gases.
Page 6
eNgliSH fUNctiONal OPeRatiONS diagRaM state of the art installation and proper system operation include a series of activities: 1. Preliminary activities: verification of the suitability of the installation site, verification of the suitability of the fumes exhaust system, ...
eNgliSH iNStallatiON iNStallatiONS NOt allOwed Installation in premises with fire hazards is forbidden. Installation in residential premises (except for sealed operation appliances) is also forbidden: in which there are liquid fuel-operated appliances with continuous or intermittent operation, which draw the combustion air in the room in which they are installed, or ...
Page 8
eNgliSH veNtilatiON aNd aeRatiON Of tHe iNStallatiON PReMiSeS Ventilation is deemed sufficient when the room is equipped with air inlets according to the table: air inlet see figure 2 Percentage of the net opening section with Minimum net opening value of Appliance categories Reference standard respect to the appliance fumes...
eNgliSH distance from combustible materials, indicated in millimetres, followed by the arrow and flame symbol; installer data and date of installation. every time one must cross combustible materials, the following indications must be complied with: SyMbOl deScRiPtiON qUOta[MM] Minimum distance of combustible materials from the intrados of the framework/floor/wall Minimum distance of combustible materials from the extrados of the framework/floor Minimum distance from combustible materials defined by the manufacturer...
Page 10
eNgliSH counter-slope sections are not allowed; the smoke ducts must have, along their entire length, a diameter that is no less than that of the attachment of the appliance exhaust pipe; any section changes are allowed only on the inlet to the chimney; ...
Page 11
eNgliSH exaMPleS Of cORRect cONNectiON tO tHe cHiMNey protection from rain protection from rain and wind and wind steel plate, airtight Max 3 mt 3 - 5% Insulated "t" fitting with inspection plug "t" fitting with "t" fitting with inspection plug inspection plug...
Page 12
eNgliSH combustion products outlet quota the outlet quota is determined by measuring the minimum height between the roof covering and the lower point of the fumes expulsion section into the atmosphere; this quota must be outside the reflux area and at an adequate distance from obstacles which hinder or make the expulsion of the combustion products difficult or from openings or accessible areas.
eNgliSH coverings and finishings the coverings and finishings must only be applied after having verified the proper operation of the appliance according to the indicated modalities tecHNical iNStallatiON dOcUMeNtatiON When installation is complete, the installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
MOtOR. dO nOt COveR OR ClOse duCting! duCting Of tHe viviana plus MOdel CannOt Be adjusted. BY default its funCtiOning is paRallel tO fROnt ventilatiOn. see tHe fOllOWing CHapteR fOR its ManageMent.
englisH additiOnal tHeRMOstat funCtiOning fOR duCting MOtOR COntROl For models with ducting motor there is also the possibility of thermostatting the motor itself. The connection of an external thermostat will allow to control the ducting motor independently from stove functioning. At this point just set the desired temperature on the thermostat.
enGlish The Display DescripTion of conTrols anD symbols ON/OFF Display OF variOUs Display BUTTON TexT messages OF pOwer OperaTiON pOwer TemperaTUre seTTiNg aDJUsTmeNT Display icons key indicates the presence of an alarm. it indicates weekly programming functioning On: indicates the presence of an alarm indicator on = weekly programming active Off: indicates the absence of alarms indicator off = weekly programming not active...
enGlish menu sTrucTure key 1 to confirm parameter/ programming and exit. keys 2 and 3 to set data/parameters. keys 4 and 5 to go forward or backward in the menu. To access the menu, keep key 5 pressed for a few seconds. seT clock 2 - 3 hours...
enGlish remoTe conTrol (opTional) commissioninG seTTinGs The heating power, the desired room temperature (only Once the power cable at the back of the stove has been with the room probe option connected) and the appliance connected, move the switch, also located on the back, to (i). ignition/switch off, can be adjusted using the remote control.
enGlish funcTioninG anD loGic iGniTion start Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition phase. after ignition and having reached the control temperature, the stove interrupts the ignition phase and passes to sTarTiNg.
enGlish user menu pelleT feeD aDjusTmenT The following menu allows the adjustment of pellet feed as a percentage. if the stove has functioning problems owing to the quantity of pellets, adjust pellet feeding directly from the control board. The problems correlated to the amount of fuel can be divided into 2 categories: NO FUel: ...
enGlish sTanD - by The stby function is used if immediate stove switch-off is required when temperature has been reached. The sTBy function can be set at ON or OFF using the procedure that will be described. in the factory the sTby function is always set at off (indicator off) sTBy FUNCTiON seT aT ON if the stby function is active (ON), when the stove reaches the room temperature set exceeding it by 2°C, it will switch off after a factory set delay time, displaying sTaND - By.
enGlish proGramminG example let's suppose that the weekly programmer function is to be used and 2 time periods are to be used in the following way: 1st time period: from 08:00 to 12:00 every day of the week excluding saturday and sunday 2nd time period: from 15:00 to 22:00 only saturday and sunday.
englisH Cleaning under user's responsibility Some images could be offset from the original model. MontHly daily Cleaning the heat exchanger:the heat exchangers burn pot: remove the burn pot from the relevant chamber must be cleaned every month as the soot compartment and free the holes using the appropriate fire deposited on the rear of the cast iron hearth wall blocks the irons supplied, remove the ash from the burn pot using...
englisH routine MaintenanCe In order to guarantee proper functioning and safety of the device, the operations indicated below must be performed every season or more often when necessary. door, asH draWer and burn pot gasKets The gaskets guarantee the tightness of the stove and its consequent good functioning. These must be checked regularly: if they should be worn or damaged they must be replaced immediately.
englisH Displays Display Reason solution Stove off staRt The start phase is in progress pellet feeDing The feeding of the pellet during the ignition phase is in progress ignition The ignition phase is in progress staRt-up The start phase is in progress WoRk The normal work phase is in progress MoDulation...
englisH alaRMs Display explanation solution On: indicates the presence of an alarm Off: indicates the absence of alarms Flashing: indicates the deactivation of the depression sensor. Indicates the presence of an alarm. The alarm can be reset by pressing key 3 for 3 seconds only if the fumes motor has stopped and if 15 minutes have passed from displaying the same alarm.
EXTRAFLAME S.p.A. is not liable for any damage that can, directly or indirectly, affect persons, objects and pets as a consequence of failure to comply with the prescriptions indicated in this manual/book.
Page 28
Masonry work The system particulars for the production of domestic hot water not supplied by EXTRAFLAME S.p.A. (water products only). The heat exchanger is excluded from the warranty unless an adequate anti-condensate circuit is realised, which guarantees a minimum return temperature of the appliance of at least 55°C (only water products).
Page 32
www.lanordica-extraflame.com Extraflame reserves the right to vary the features and data shown in this booklet at any time and without prior notice, in order to improve its products. This manual cannot be considered as a contract for third parties.