Page 15
7.8
No acoustic programmer acknowledge
Only SREL.ADV
Mark this field if you want no programmer acknowledge to be given via a connected
buzzer/beeper when the Smart Relay is programmed.
7.9
External beeper/ External LED
Only SREL.ADV
This is where you specify which external unit is connected. In Flip Flop mode, the
Smart Relay generates a continuous signal when switched if there is an external LED
connected; if a beeper is connected, it briefly acknowledges each change of state
with a sound signal.
7.10
Internal/ external antenna
Only SREL.ADV
-
Autodetection:
If an external antenna is connected, only this antenna is used. The Smart
Relay then switches the internal antenna off. If no external antenna is
connected (default case), the Smart Relay works with the internal antenna.
-
Both active:
The Smart Relay can assess entries from transponders at both antennas.
7.11
Number of expansion modules
Only for SREL.ADV
This is where you indicate the number of external modules that are connected to the
Smart Relay. These modules are connected to terminals RS-485 COM, RS-485
A and RS-485 B. For more information, refer to the documentation for the separate
modules.
7.12
Pulse length
This is where you specify the value, in seconds, for the pulse width of the switching
pulse. The value has a range from 0.1 to 25.5 seconds. For example, if you enter
3 seconds here, then a door opener will be released for 3 seconds before it is then
blocked again.
Smart Relay: SREL, SREL.ZK, SREL.ADV