Esse 700 27B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse Stoves & Cookers Long Ing. Barnoldswick, Lancashire BB18 6BN. United Kingdom. Tel: + 44 (0) 1282 813235 F: + 44 (0) 1282 816876 enquiries@esse.com www.esse.com...
INSTALLATION & OPERATING INSTRUCTIONS FOR THE ESSE 700 27B MODEL U.K. & Ireland READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE Contents Safety Notes Page 3 Page 4 INSTALLATION INSTRUCTIONS Chimney and Flue Page 4 Flue and Draught Measurement Page 5...
SAFETY NOTES Properly installed, operated and maintained, this appliance will not emit • fumes into the dwelling. However occasional fumes from de-ashing and re- fuelling may occur. Persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, open doors and windows to ventilate the room.
Installation Instructions The installer has a responsibility under the Health and Safety at Work Act 1974 to provide for the safety of persons carrying out the installation. Attention is drawn to the fact that fire cement is caustic and hands must be washed thoroughly after use.
Fig: 1- Chimney and flue performance. Fig: 2-Top flue installation only 700 17B model Flue Liner Insulation Flue Access Flue Draught Measurement The chimney can be checked, before the stove is installed, with a smoke match. If the chimney doesn’t pull the smoke it may suggest the chimney needs attention (see the Flue Diagnosis Table below).
reading can be taken with the stove lit. Two flue draught readings should be taken, one with the stove at minimum firing rate and one at maximum firing rate. Measurement The flue draught test hole must be drilled in the flue pipe as close to the stove as possible and before any flue draught stabiliser.
Flue Stabilizer A flue stabilizer can be fitted to reduce the draught through the stove if the flue draught is too high. The flue stabilizer should be; • fitted in the same room as the stove, • the same size as the flue pipe, and fitted no closer than 700mm to the flue outlet of the appliance.
When a Wooden mantle is intended to be installed, at least 18-24” (460-600mm) clearance is required to the stove. It may also be required to fit heat shields in relevant areas. Flue connection – 700-17B model Stove The flue pipe used to connect the stove to the chimney is 6"(150mm) diameter. The stove is supplied ready for top flue connection complete with a 5-6”...
Page 9
Perforated sides and back Vermiculite/metal side front Vermiculite/metal side rear Ashpan Steel plate Cast plate Front Bar Operating Tool Secondary Air Tube Boiler...
Boiler Boiler Fig 5 DOOR LOCKING CATCH BOTTOMGRATE ASHPAN Open Fig: 6 - Secondary air control – 700 17B model Stove Stove Outputs The maximum Output of the 700 17B Model is 8.0 kW (27,296 Btu/h) to water and 9.0kW (30.700 Btu/h) to the room. The figures are based upon burning 5.0Kg of wood/hour with all controls open and doors closed.
is 3.75Kw (12,800Btu’s/h) to water with all controls closed using the same fuel load. The water capacity of the boiler is 7.1 litres. The Domestic and Central Heating System The domestic and central heating system must comply with BS:5449 Part 1. When fitting a joint central heating &...
The water flow rate should be adjusted to suit the circuit and the whole system balanced properly. B oiler Tapping Information. Ouzledale Foundry Co Ltd, Long ing, Barnoldswick, Lancashire BB18 6BN England Http: //www.esse.co.uk 05/07...