Do you have a question about the PM 15kW and is the answer not in the manual?
Questions and answers
Summary of Contents for BURNiT PM 15kW
Page 1
Installer / Service Instruction Manual for installation of pellet stoves BURNiT Comfort PM (with water jacket) and PM-B (with water jacket and metal insulated door) NES – New Energy Systems Ltd. 12 Madara Blvd. 9700 Shumen, Bulgaria tel: +359 54 874 536; +359 54 874 555 fax: +359 54 874 556 e-mail: service@sunsystem.bg...
Page 2
Installer / Service Manual BURNiT Comfort PM/PM-B Table of contents: Safety measures Technical characteristics Installing the pellet stove Installing and first start of the pellet stove User interface User menu Working mode What happens if… 8.1 The pellets do not drop into the burning chamber, although the pellet stove is switched on 8.2 Electricity power cut off (transitory blackouts)
Page 3
800 kg to 1000 kg or if usage is less at least once a year. This maintenance must be performed by an authorized by BURNIT service center. As long as the pellet stove is in its warranty period all the maintenance and service must be performed by the authorized service who has performed the initial installation.
Installer / Service Manual BURNiT Comfort PM/PM-B end user must notify authorized service /installer BURNiT. It is not recommended to deactivate or restart the safety functions of the product at your own. You must have a fire extinguisher in the room where the pellet stove is installed in case of fire in the exhaust gases tube.
Page 5
2.2 Functional description of the pellet stove The pellet stove BURNiT Comfort PM - 15kW, 23kW with water jacket is designed to be connected to a heating installation and is suitable for use in houses, offices, small restaurants etc. The product contributes for the comfort and the nice atmosphere in the room.
Page 6
Installer / Service Manual BURNiT Comfort PM/PM-B 2.3 Technical parameters Model PM / PM-B 15 kW 23 kW Height mm 1080 Width mm Depth mm Weight kg Inlet air tube, diameter mm Exhaust gases tube, diameter mm Container for pellets - capacity – max. quantity kg...
Page 7
Installer / Service Manual BURNiT Comfort PM/PM-B 2.4. Mounting the controller of the pellet stove Open the cover of the container for pellets situated on the top of the product. Inside you will find the packed controller (2), together with a set of bolts M5 (3).
Page 8
Installer / Service Manual BURNiT Comfort PM/PM-B Functional description of the controller for pellet stoves BURNiT Comfort PM (with water jacket) / PM-В (with water jacket and metal insulated door) This instruction describes the controller of the IO23. This controller is used for pellet stoves/boilers using wooden pellets as fuel.
Any mistakes done during the installation are not covered by the MANUFACTURER. It is obligatory the installation, the first start and the maintenance of the pellet stove to be performed by an authorized installer/service BURNiT! Recommendations BEFORE installing the pellet stove: Check the minimum volume of the room where the pellet stove is to be installed (should be no ...
Page 10
3.3 System for exhaust gases The correct installed system for exhaust gases is of extreme importance. It is obligatory the installation to be performed by an authorized installer / service BURNiT ! Recommended parameters for installing the exhaust gases system:...
Page 11
Installer / Service Manual BURNiT Comfort PM/PM-B 3.4 Exhaust gas system requirements: We recommend the Exhaust gas system to meet the following requirements: To be manufactured for suitable for the purpose materials. To be hermetically sealed - the tubes for the chimney to be with silicone gaskets.
Page 12
Installer / Service Manual BURNiT Comfort PM/PM-B 3.6 Pattern for installing the exhaust gas system /connecting the pellet stove to chimney/ The below patterns are only example. 12 - EN...
Page 13
Installer / Service Manual BURNiT Comfort PM/PM-B 3.7 Installation of the exhaust gases pipe on the roof The upper part of the pipe (chimney) is dеsigned for the proper outlet of the exhaust gases in the atmosphere. The tube must be protected from rain, snow and all objects, and to ensure discharging of exhaust gases in the atmosphere under windy conditions.
Installer / Service Manual BURNiT Comfort PM/PM-B 3.8 Connection to the power supply Once the pellet stove is installed in the room it must be connected to the power supply. The power cable is situated at the back part of the pellet stove. Check the condition of the cable. If any damages are noticed notify an authorized service for exchange.
Page 15
Installer / Service Manual BURNiT Comfort PM/PM-B 4.1. Connecting the controller CONNECTORS DESCRIPTION EXPLANATION GROUNDING(EARTHING) OUTGOING FAN NO 2 OROLOG CONNECTOR CHRONOTHERMOSTAT (OPTIONAL) ZERO INPUT ALARM SAFETY THERMOSTAT INPUT ALARM SAFETY PRESSURE REGULATOR OUTPUT HEATING ELEMENT OUTPUT AUGER GEAR MOTOR...
Installer / Service Manual BURNiT Comfort PM/PM-B 4.3. Automatic test of the controller The manufacturer of the controller, company Micronova, has an automatic system test for check up of all the components at the end of its production line. 4.4. Before the first start of the pellet stove Once you have the installation finished the first ignition can be done and all the parameters can be set up.
Installer / Service Manual BURNiT Comfort PM/PM-B 5. User interface The display communicates with the mainboard of the controller only with the push buttons and gives information to the user about the working condition of the pellet stove. The user can change parameters.
Page 19
Installer / Service Manual BURNiT Comfort PM/PM-B INPUT MENU STATUS MODE 5.2 Menu keys explanations EXPLANATIONS WORKING MODE ACTION INCREASING THE PROGRAMMING INCREASING THE PARAMETER TEMPERATURE VALUE WORKING/NOT INCREASING THE WATER/ROOM WORKING THERMOSTAT TEMPERATURE DECREASING THE PROGRAMMING DECREASING THE PARAMETER...
Page 20
Installer / Service Manual BURNiT Comfort PM/PM-B 6. User menu When key P3 (menu) is pushed you switch to MENU mode. It is divided into several levels in order to be able to enter the programming set up modes of the controller.
Page 21
Installer / Service Manual BURNiT Comfort PM/PM-B 21 END Program 3 Time 22 Program Monday 3 On/ Off 23 Програма Program On/ Off Tuesday 3 24 Program Wednesday 3 On/ Off 25 Program Thursday 3 On/ Off 26 Program Friday 3...
Page 22
Installer / Service Manual BURNiT Comfort PM/PM-B 6.1. Menu 01 – Clock set up Set up time and date. The controller is equipped with lithium battery which allows it to work independently from 3 to 5 years. INPUT MENU LEVEL...
Page 23
Installer / Service Manual BURNiT Comfort PM/PM-B Submenu 02-03- Weekly programming Allows setting up all the weekly functions of the chrono - thermostat INPUT MENU LEVEL DIALOGUE SCREEN The weekly timer has 4 (four) independent programs which can be combined. The weekly timer could be activated or deactivated.
Page 24
Installer / Service Manual BURNiT Comfort PM/PM-B PROGRAM 3 MENU LEVEL CHOICE DESCRIPTION VALUES 02-03-20 START PROGRAM 3 Activate TIME ON/ OFF 02-03-21 STOP PROGRAM 3 Deactivate 02-03-22 MONDAY PROGRAM 3 ON/ OFF 02-03-23 TUESDAY PROGRAM 3 ON/ OFF 02-03-24...
Page 25
Installer / Service Manual BURNiT Comfort PM/PM-B 6.3 Menu 03- Language choice This menu allows for choosing between different languages. MENU LEVEL ENGLISH LANGUAGE DIALOGUE SCREEN 6.4 MENU 04- Choosing season. Choose WINTER from this menu. 6.5. MENU 05 – STAN BY MODE STAND BY MODE ON-is activated –...
Page 26
Installer / Service Manual BURNiT Comfort PM/PM-B 6.8 MENU 08 – PELLET STOVE MODE This menu visualizes the mode of the pellet stove with checking all the attached to it application. The menu has some coherent screens. See 6.2 TIMER 1...
Installer / Service Manual BURNiT Comfort PM/PM-B 7. Working mode In this paragraph the function of the controller is described for the end user. The explanation is for controller with chrono-thermostat. You will find the technical description below: TIME ROOM TEMPERATURE DIALOGUE SCREEN SUPPLY 7.1 Switching on the pellet stove...
Page 28
Installer / Service Manual BURNiT Comfort PM/PM-B 7.2 IGNITION MODE The pellet stove is performing the ignition phase in accordance of the set up parameters and values. Check appendix A and C. Registering fire Once the temperature of the exhaust gases is above the parameters PR13, the pellet stove is reached the ignition mode.
Page 29
Installer / Service Manual BURNiT Comfort PM/PM-B 7.4. Inability for switching the pellet stove ON If the Pr01 is exceeded and the exhaust gases temperature has not reached the set up minimum of parameter Pr13, reached in deviation of 2 (two) degrees VC/MIN, the pellet stove gives alarm.
Page 30
Installer / Service Manual BURNiT Comfort PM/PM-B The room temperature reaches the temperature set. When the room temperature reaches the temperature set, the power of the pellet stove decreases automatically – MODULATION MODE. The pump is active while the water temperature is decreasing until it reaches parameter PR 15. After that it switches OFF.
Page 31
Installer / Service Manual BURNiT Comfort PM/PM-B The water temperature is increasing If at restricted functions of the pellet stove in MODULATION mode the temperature of the water increases the value Tseth 2 ° -3 ° C, for a period longer than Pr23, the pellet stove switches OFF.
Page 32
Installer / Service Manual BURNiT Comfort PM/PM-B 7.11. Changing the power of the pellet stove In regular working mode you can change the power of the pellet stove. Use key P6 – increasing the power and key P7 – decreasing the power. The power level is shown in the upper part of the screen.
Page 33
Installer / Service Manual BURNiT Comfort PM/PM-B 7.14. The pellet stove is SWITCHED OFF TIME ROOM TEMPERATURE DIALOGUE SCREEN POWER 7.15. SWITCHING ON AGAIN THE PELLET STOVE The pellet stove cannot be switched ON again while the temperature of the exhaust gases is below the value of the parameter Pr13 and safety pause Pr38 runs out.
Installer / Service Manual BURNiT Comfort PM/PM-B 8. What happens if… 8.1 The pellet do not fall into the burner although the pellet stove is switched ON. On the screen the following message is shown NO ACC –NO FIRE. NO ACC Press key P4, in order to return back to regular working mode.
Installer / Service Manual BURNiT Comfort PM/PM-B After the pellet stove is with power supply cut off, depending of the mode canceled, on the screen the following message displays: Previous MODE Duration of NEW MODE time without power Switching ON...
Page 36
Installer / Service Manual BURNiT Comfort PM/PM-B 9.1 Message Temperature exhaust gases/smoke probe “ALARM SOND” Each time when the probe for measuring the exhaust gases temperature do not works or is not connected the following message is displayed on the screen “ALARM SOND” – Message Temperature exhaust gases probe.
Page 37
Installer / Service Manual BURNiT Comfort PM/PM-B 9.5 Message for the auger pressure switch “ALARM DEP FAIL” If the pressure switch reports lower pressure for switching ON from the parameters set, it switches ON or OFF the auger – the auger works on intervals for example. These actions are transmitted to the controller through input AL2 to CN4.
Page 38
Installer / Service Manual BURNiT Comfort PM/PM-B 10. Cleaning and maintenance Clean regularly the pellet stove and the exhaust gases system. This ensures the efficient work of the pellet stove. IMPORTANT! When cleaning the pellet stove or the exhaust gases system do not use detergents containing acid or flammable substances.
Page 39
Installer / Service Manual BURNiT Comfort PM/PM-B Cleaning the door glass The door glass cleans itself during working mode. Although it is possible after several hours of work the glass to dim from the inside. The reason for this is the quality of the pellets and the work of the exhaust gases system.
Page 40
Installer / Service Manual BURNiT Comfort PM/PM-B Cleaning the pellet silo It is recommended to periodically clean the silo (at least once per month). The cleaning must be done as following: first empty the pellet silo and then clean it with a vacuum cleaner.
Page 41
Installer / Service Manual BURNiT Comfort PM/PM-B 3) Model 15kW – Clean off accumulated soot from inspection openings under the burner Close the system after that. If you use low quality pellets we recommend you to clean it once per month.
Installer / Service Manual BURNiT Comfort PM/PM-B 12 Aftersales service When you have bought a pellet stove you must contact an authorized installer/service for installation and start. The authorized installer/service fills in the warranty card and the service manual of the product.
Page 44
Installer / Service Manual BURNiT Comfort PM/PM-B MENU for AUTHORIZED INSTALLER / SERVICE BURNiT 14. Menu MODAL MODE (the access to this menu is only for an authorized installer/service) IMPORTANT: The access to menu MODAL MODE is granted to the authorized installer/dealer who is familiar with the technical parameters of the pellet stove.
Page 45
Installer / Service Manual BURNiT Comfort PM/PM-B 04 waiting for fire Value detection 05 overfilling with smoke Value of the exhaust gases fan 06 Delta on/off – Value automatically turned OFF 07 Postponed Value automatically turned OFF 08 speed change...
Page 46
Installer / Service Manual BURNiT Comfort PM/PM-B 14.1 Submenu 09-01-01 Pellets supply LOAD PELLET The value for pellet supply is fixed by pressing the keys P1 and P2. Confirm by pressing key Р3. 14.2 Submenu 09-02-01 Chimney type FAN FUME STOVE The speed of the exhaust gases fan is set up by pressing keys P1 and P2.
Page 47
Installer / Service Manual BURNiT Comfort PM/PM-B 14.8 Submenu 09-08 Cancellation of partially specified hours You can enter this submenu only using the access code. You can cancel the partially specified hours with it. 14.9 Submenu 09-09 Cancellation of messages/alarms You can enter this submenu only using the access code.
Page 48
Installer / Service Manual BURNiT Comfort PM/PM-B 14.13 Creating personal data (*) Creating and memorizing of personal data is possible by using the SERAMI software – with serial connection to the card interface PS232. This is done as follows: Load the data in the card (O0, O1 и т.н.) from menu 09-03, in the desired sequence and volume.
Page 49
Installer / Service Manual BURNiT Comfort PM/PM-B After these settings the card will work according the parameters copied from the initial card. You can input different configurations in this way. Important: Each time you enter new data (O0,O1,..) you must follow the procedure described in NUMBER (*) See instruction manual for SERAMI SOFTWARE.
Page 50
Installer / Service Manual BURNiT Comfort PM/PM-B 15. APPENDIXES 15.1. APENDIX А: Parameters for pellet stove with water jacket PM /PM-B 15 kW, 23kW The data could be changed according to the version update (*) Para LEVEL Explanation Unit Value...
Page 51
Installer / Service Manual BURNiT Comfort PM/PM-B Pr 24 M-9-6-24 Heat exchanger fan speed 1 in VOLT supply mode 2 Pr 25 M-9-6-25 Heat exchanger fan speed 1 in VOLT supply mode 3 Pr 26 M-9-6-26 Heat exchanger fan speed 1 in...
Page 52
Installer / Service Manual BURNiT Comfort PM/PM-B Ways of switching off the auger time parameters The command for the auger time setting is temporal and is structured as following: a period is defined T=8S, and the motor is switching on for time Pr04, Pr05, Pr06, Pr07, Pr08, Pr09 и Pr10 , according the working mode.
Page 53
Installer / Service Manual BURNiT Comfort PM/PM-B 15.2. Appendix B : First start and work conditions 53 - EN...