8.1 Active Equalisation Modules ......10 8.2 Cloud CDI-S100 Serial Interface Module ....11 9 Remote Music Mute - Fire Alarm interface .
Page 6
12.2 Connecting balanced signals to unbalanced line inputs ..13 12.3 Cloud CDI-S100 Serial interface is not working properly ..14 12.4 Microphone access switches not working correctly ..15...
General Description The Cloud CX462 is a versatile, microphone and line input mixer. The mixer has a music section with six stereo line inputs. A source select control routes the desired line input to the stereo music outputs. It has a microphone section with four microphone inputs that are mixed and sent to the separate, mono mic output.
The CX462 is 152.5mm deep but a depth of 200mm should be allowed to clear connectors. Stereo/Music Inputs The music section of the CX462 has six stereo inputs. These line inputs are suitable for most music sources such as compact disc players, tape players and receivers etc.. All inputs are unbalanced and use RCA type phono connectors.
The music source and music level control functions can be controlled from either the front panel or a remote control plate located up to 100m from the CX462. There are two remote control plates available for the CX462, the RSL-6 and the RL-1. The RSL-6 should be used...
CX462 Audio System Controller Setup And Installation Guide CLOUD ELECTRONICS LIMITED Music Control continued Remote control enabling jumpers J9: Music source J10: Music level Location of Jumpers J9 & J10 The RSL-6A and RL-1A are available for the American market. They have identical operation to the RSL-6 and RL-1 but have been designed to fit a single gang US electrical outlet box.
CX462 Audio System Controller Setup And Installation Guide CLOUD ELECTRONICS LIMITED Line 6 Priority continued Line 6 Priority Jumpers J11: Priority on/off J12: Release time 6 Microphone Inputs Location of Jumpers J11 & J12 Four microphone inputs are provided each having electronically balanced, transformer-less circuitry configured for optimum low noise performance.
CX462 Audio System Controller Setup And Installation Guide CLOUD ELECTRONICS LIMITED 6.1 Microphone Access Contacts Access contacts for each individual microphone input are provided on the rear panel. Individual microphone inputs can be activated by connecting their respective contact to the 0V contact, leaving the access terminal open circuit will mute the microphone input.
Master microphone level can be controlled locally via the front panel rotary control, or through a remote wall plate up to 100m away from the unit. To configure the CX462 for STANDARD WIRING CONVENTION remote level operation, the front panel switch USE TWO CORE SCREENED CABLE must be in the 'REMOTE' position.
6.7 Microphone over Music priority The CX462 provides a facility whereby microphone signals can be given priority over music signals. When a signal is detected on any of the mic inputs, all music signals are attenuated to a level determined by the front panel attenuation control. Once there is no microphone signal present, the music will restore to the previous settings.
(inner core) to pin 3 and make no connection to pin 2. The music output of the CX462 can operate in either stereo or mono mode. The default setting is for the CX462 to operate in stereo mode. In mono mode, all stereo signal sources are mixed internally and output the same signal to both left and right channel music outputs.
CON3 or CON4 depending on the output socket you choose to use. Installation: Switch off the mains supply and remove the CX462's power lead. Remove the unit's top panel Fit the EQ module to the connector. The EQ card board should be perpendicular to the main board.
CLOUD ELECTRONICS LIMITED 8.2 Cloud CDI-S100 Serial Interface Module The CX462 can be used as part of an automated sound system through the use of the CDI-S100 Serial Interface Module. The module can control: M Music source, level and mute...
The CX462 provides a facility to mute the music signals only, by using a fully isolated pair of contacts. This is usually a relay mounted close to the CX462, which is powered by the fire alarm control panel. The relay can either be closed or opened in an alarm condition, but the internal jumper J13 MUST be set to the corresponding position: M N/C: Alarm condition when the relay opens.
CX462 line inputs. The transformer should be mounted close to the CX462 and the unbalanced output lead should be kept as short as possible. Where both the source and destination units are earthed, it is important to isolate the primary and secondary windings to avoid a potential ground loop;...
M The rear panel switch marked 'REMOTE TYPE' should be in the 'DIGITAL' position. If the module is still not working correctly once these aspects of the CX462 unit have been configured, consult the module manual for details of the serial port connections and the communications protocol.
12.4 Microphone access switches not working correctly The CX462 leaves the factory configured to bypass the microphone access contacts for all four microphone inputs, so that when the product arrives, all inputs will be enabled. Internal jumpers J1 to J4 bypass access contacts for microphones 1 to 4 respectively. To enable access switching on one of the microphone channels, disconnect the corresponding jumper.
Only reassemble the unit using screws identical to the original parts. In the interest of continuing improvements Cloud Electronics Limited reserves the right to alter specifications without prior notice. Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Telephone +44 (0) 114 244 7051 Fax +44 (0) 114 242 5462 E-mail: Info@cloud.co.uk...