Mechanical Shutter Adjustment; Light Value Adjustment - Sony DSC-P51M Service Manual

Digital still camera
Table of Contents

Advertisement

6. Mechanical Shutter Adjustment

Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
B8 to D7
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
1
2
3
6
01
AD
4
6
02
5
6
AB
Note 2: The adjustment data will be automatically input to page:
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
RadarW
RadarW
RadarW
RadarW
RadarW
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Perform "Picture Frame
setting".
(Refer to page 5-14)
Press PAUSE button.
(Note 2)
Check the data changes to
"01".
Check the data is "00".
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-13)

7. Light Value Adjustment

Adjust the standard LV value.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Adjusting method:
Order Page Address Data
1
2
3
6
01
4
6
02
5
0
03
6
1
7
F
65
Note 3: The adjustment data will be automatically input to page:
F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
03
3
5-19
DSC-P51/P51M
RadarW
RadarW
RadarW
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Displayed data of page: 1 (Note
2) and page: F, address: 65
Adjusting remote commander
F
65 to 67
AE level 1: 0FE0 to 1020
AE level 2: 34 to 4A
Displayed data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Perform "Picture Frame
setting".
(Refer to page 5-14)
Press PAUSE button.
0D
(Note 4)
Check the data changes to
"01".
06
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
Check that the displayed data
satisfies the AE level 2
specified value.
Procedure
00
Press PAUSE button.
00
Release the data setting
performed at step 1.
(Refer to page 5-13)