The Component Test Charts
COMPONENT
ILLUSTRATION
L1
L2
H2
P
H1
L1
L2
P
H1
H2
CONTROL PANEL
SHUTDOWN SWITCH
&
COOLING FAN
THERMAL SWITCH
BAKE ELEMENT
SHUTDOWN SWITCH
TERMINALS
SOLENOID
TERMINALS
Test Chart 1
COMPONENT
Electronics Board
Infinite Switches
Cooling Fan Thermostat
Bake & Broil Element
Shutdown Switch
OR
Bake Burner Shutdown
Switch
Door Latch Solenoid
TEST PROCEDURE
Test all input and output
connections to board.
Set the ohmmeter to
R x 1.
Connect the meter leads
to the switch terminals,
and measure the conti-
nuity when the switch is
turned ON and OFF.
Set the ohmmeter to
R x 1.
Connect the meter leads
to the thermostat termi-
nals, and measure the
continuity when the
switch is heated above
104˚F, and then cools to
below 104˚F.
Set the ohmmeter to
R x 1.
Connect the meter leads
to the thermostat termi-
nals, and measure the
continuity when the
switch is heated above
395˚F, and then cools to
below 395˚F.
Set the ohmmeter to
R x 10.
Connect one of the
meter leads to circuit
board pin J1-1.
Connect the other meter
lead to circuit board pin
J1-8.
- 31 -
TEST RESULTS
Refer to the error codes
on the previous two
pages.
Switch ON Switch OFF
L1-P = 0 Ω L1-P =
L1-H1 = 0 Ω L1-H1 =
L2-H2 = 0 Ω L2-H2 =
Above 104˚F = 0 Ω.
Ω.
Below 104˚F =
Above 395˚F = 0 Ω.
Ω.
Below 395˚F =
55 Ω. ±10 Ω