Bosch ICP-AMAX4-P1 Installation Manual page 71

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

AMAX panel 4000 / AMAX panel 4000
EN
Output Options
The value ranges of output programming options
Output event type
Output
Event
Bosch Sicherheitssysteme GmbH
Description
0
Not used
1
System disarmed
2
System armed
3
System alarm
4
System alarm (audile and silent)
5
External AWAY siren
6
External STAY siren
7
Internal siren
8
Internal siren with tamper
9
Entry / Exit delay warning
10
Telephone line fault
11
AC power supply fault
12
Low battery
13
Tamper
14
External fault
15
All faults
16
Fire alarm
17
Fire reset
18
AWAY armed
19
STAY armed
20
Reset *1
21
Follow zone event
22
RF keyfob button 3 (garage door)
23
RF keyfob button 4 (light)
24
Chime indication *1
25
Verified alarm
26
Unverified alarm
27
Technical alarm
28
Bypassed zone
29
Ready to arm
Installation Guide
Settings | en
Output area / zone
No
0 = All areas
1 – 16 = areas 1 – 16*
0 = Any area
1 - 16 = areas 1 - 16*
1 - 16 = areas 1 - 16*
0 = Any area
1 - 16 = areas 1 - 16*
0 = Any area
1 - 16 = areas 1 - 16*
0 = All areas
1 - 16 = areas 1 - 16*
0 = Any area
1 - 16 = areas 1 - 16*
Zone number 1 - 64*
0 = Any area
1 - 16 = areas 1 - 16*
0 = All areas 1 - 16 = Areas 1 - 16*
2014.4 | 01 | F.01U.267.112
71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-amax4-p2-enIcp-amax-p3-enAmax 4000Amax 4000en

Table of Contents