5.
CONTROL BOARD 780D
5.1.
WARNINGS
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
•
Check local wiring codes in all cases and follow all local building
codes. Wiring and hookup should be performed by qualified
electricians/installers only.
•
AC power should be supplied from a circuit breaker panel and
must have its own dedicated circuit breaker. This supply must
include a green ground conductor.
•
Properly ground the gate operator to minimize or prevent damage
from power surges and/or lightning. Use a grounding rod if neces-
sary. Connect the ground cable to the PE terminal on J7 (Fig. 22),
and to the ground lug on the operator (Fig. 40). A surge suppres-
sor is recommended for additional protection.
•
Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.).
5.2.
780D TECHNICAL SPECIFICATIONS
Power Supply V~
115 or 230
(+6% -10%)
Absorbed Power (W)
10
Motor Max. Load (W)
1000
Accessories Max.
0.5
Load (A)
Operating Ambient
-4°F to +131°F
Temperature
Protection Fuses
2 (see Fig. 22 and Section 5.3)
Function Logics
Automatic / "Stepped" automatic /
Semi-automatic / Safety devices /
Semi-automatic B / Dead-man C /
"Stepped" semi-automatic / Mixed B/C
logic
Work Time
Programmable (from 0 to 4.1 min.)
Pause Time
Programmable (from 0 to 4.1 min.)
Thrust Force
Adjustable over 50 levels
Terminal Board
Open - Partial Open - Opening safety
Inputs
devices - Closing safety devices - Stop
- Edge - Power supply+ground
On-Connector Inputs
Opening and closing limit-switch -
Motor capacitor
J7
F1
FA A C M ODE L 8 44 S l i d e G at e Ope ra tor
J5
J6
F2
780D Technical Specifications (continued)
Terminal Board
Outputs
Rapid Connector
Programming
5.3.
LAYOUT AND COMPONENTS
DL
SIGNALLING AND PROGRAMMING DISPLAY
Led
INPUTS STATUS CONTROL LED
J1
LOW VOLTAGE TERMINAL BLOCK
J2
CONNECTOR FOR RP RECEIVER
J5
CONNECTOR FOR MOTOR STARTING CAPACITOR
J6
MOTOR AND FLASHING LAMP CONNECTION TERMINAL BLOCK
J7
VAC POWER SUPPLY TERMINAL BLOCK
J8
DOUBLE CONNECTOR - RAPID CONNECTION TO LIMIT-SWITCH
F1
MOTOR AND TRANSFORMER PRIMARY WINDING FUSE (F 5A - 230V;
F 10A - 115V)
F2
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F
"F" PROGRAMMING PUSH-BUTTON
–
"–" PROGRAMMING PUSH-BUTTON
+
"+" PROGRAMMING PUSH-BUTTON
J1 CONNECTOR
1
OPEN A (total opening)
2
OPEN B (partial opening)
3
FSW-OP (opening safety devices)
4
FSW-CL (closing safety devices)
5
STOP
6
SAFE ("edge" safety devices)
7
- (negative for power supply to accessories)
8
- (negative for power supply to accessories)
9
+24V (supply to accessories)
10
+24V (supply to accessories)
11
FSW-TX (negative for emitting photocells - FAILSAFE)
12
AA (negative for Audio Alarm)
–
+
J8
DL
Led
Flashing lamp - Motor - 24 VDC
accessories power supply- 24 VDC
indicator-light / Timed output / Electric
lock command - 'traffic lights' - Failsafe
5-pin card connection for RP receivers
3 keys (+, -, F) and display, "basic" or
"advanced" mode
F
J1
Led
J2
Fig. 22
12
Need help?
Do you have a question about the 844 and is the answer not in the manual?
Questions and answers