Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
Programming Item (Item Number)
Point Type (9091)
Circuit Style (9092)
Include in Custom Protection (9093)
Cross Zone Enabled (9094)
Wireless Detector Sensitivity (9098)
Voice Description
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
Programming Item (Item Number)
Point Type (9101)
Circuit Style (9102)
Include in Custom Protection (9103)
Cross Zone Enabled (9104)
Wireless Detector Sensitivity (9108)
Voice Description
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
Programming Item (Item Number)
Point Type (9111)
Circuit Style (9112)
Include in Custom Protection (9113)
Cross Zone Enabled (9114)
Wireless Detector Sensitivity (9118)
Voice Description
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
Programming Item (Item Number)
Point Type (9121)
Circuit Style (9122)
Include in Custom Protection (9123)
Cross Zone Enabled (9124)
Wireless Detector Sensitivity (9128)
Voice Description
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
* These options apply to the entire point range. These points cannot be individually configured.
Default
= Default value.
Default
= Country-specific default. Select this programming item to hear the updated default value.
48
Entry
Programming Item (Item Number)
Point Type (9131)
0
2
Circuit Style (9132)
0
Include in Custom Protection (9133)
Cross Zone Enabled (9134)
1
0
Wireless Detector Sensitivity (9138)
Voice Description
Point 9
Wired
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
Wireless
Entry
Programming Item (Item Number)
0
Point Type (9141)
Circuit Style (9142)
2
0
Include in Custom Protection (9143)
1
Cross Zone Enabled (9144)
Wireless Detector Sensitivity (9148)
0
Point 10
Voice Description
Wired
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
Wireless
Entry
Programming Item (Item Number)
0
Point Type (9151)
Circuit Style (9152)
2
0
Include in Custom Protection (9153)
1
Cross Zone Enabled (9154)
Wireless Detector Sensitivity (9158)
0
Point 11
Voice Description
Wired
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
Wireless
Entry
Programming Item (Item Number)
0
Point Type (9161)
2
Circuit Style (9162)
Include in Custom Protection (9163)
0
1
Cross Zone Enabled (9164)
0
Wireless Detector Sensitivity (9168)
Point 12
Voice Description
Wired
Wired (DX2010 Address 102)*
Wireless Point (Wireless Hub)*
Wireless
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Entry
0
2
0
1
0
Point 13
Wired
Wireless
Entry
0
2
0
1
0
Point 14
Wired
Wireless
Entry
0
2
0
1
0
Point 15
Wired
Wireless
Entry
0
2
0
1
0
Point 16
Wired
Wireless

Hide quick links: