Safety informations ........................... page 2 Technical features ..........................page 3 Before using ............................page 4 Lamp installation, replacement and setting ..................page 5 Installation of the dust proof filters ....................page 6 Control panel and configuration ...................... page 7 Programming functions ........................page 8 Use of the CityColor in DMX 512 .....................
WARNING SAFETY INFORMATION READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT. INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS, UV RADIATION HAZARDS AND DANGEROUS MATTERS. At the end of its working life, the product must not be disposed of as urbamn waste. It must be taken to a special local authority differentiate waste collection centre or to a dealer providing this service.
YOUR REFERENCE Always remember to give the serial number and to specify the model any time you address the seller for information or assistan- BASIC KIT The basic kit of the CityColor flood projector consist of: Available on request: TECHNICAL FEATURES LAMPS Color temperature: 5.600°K Color temperature 6.000°K...
CIRCUIT BREAKER 0,03A Studio Due CITYCOLOR art. 0002 Keep at least a distance of 0,5 mts between the apparatus and inflammable surface nearby. Disconnect the unit from power before servicing. 230Vac; 15A - 50Hz IP 67 pict.1 CONDUCTOR SIZES (length < 20mt.)
pict.2 In case of replacement of the lamp or maintenance, do not open the fixture unless 5 minutes have passed from the switching off. WARNING This operation has to be done when the apparatus is disconnected from the mains supply INSTALLATION OF THE DISCHARGE LAMP (see pic.2) 3) Open the base of the lamp room (G)
IP RATE The declared IP rate of the CityColor comes supported at these conditions: it is not possible to install the fixture outdoor with the ballast upwards WARNING The CityColor has a IP rate 44 without filters installed and an IP RATE 54 with filters installed. You must use the filters in critical working conditions and, normally, when the fixture works outdoor.
pict.4 CONTROL PANEL On the control panel of the CityColor (pict.4) you can find, besides the display, the leds and the buttons to use to set the spot. off: no DMX input off: lamp switched on off: lamp switched on BUTTONS Four buttons are used to programme the spot: DOWN...
SUMMARY OF THE PROGRAMMING FUNCTIONS OF THE CITYCOLOR Addr nChn teSt Mode LHrS FLIP rSEt FHrS Afterwards the first of the eight available menus will appear: Addr to assign the DMX-512 address Mode DMX512 mode, master with pre-set selection, slave LHrS lamp working hours FHrS...
Page 11
nChn (Number of Channel) up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). It is possible to set 6 channels or 7 channels ( remote reset and remote lamp switch off ). To go back to the options without making any change, press the MENU button.
CONNECTION THE DATA LINK (DMX 512) WIRE SIGNAL pict.5a pict.5 fig.5c fig.5b on the control panel of the fixture. (pict.5) The pin nomenclature of the connectors for the connection to the DMX signal is listed in the table. (pict.5a) In order to avoid any problem in the signal transmission, it is warmly suggested to use a cable for high speed data transmission (sect.
WARNING DMX TERMINAL LINE The wrong connection of the terminal line or its non-connection are probably the most frequent reasons for the defective functioning of the cable furthest from the transmitter. The terminator resistor should have the same value as the impedance of the connection cable.
pict.7 USE OF THE CITYCOLOR IN AUTO-MODE Press the MENU button on the control panel up to when the option MODE (pict. 7) is shown on the display, select it by pressing To go back to the options without any change, press the MENU button. Mode no use of the CityColor in DMX-512 Pr1..Pr27...
TROUBLESHOOTING GUIDE Before calling for technical assistance, follow the recommended procedures in this appendix to solve many problems on your fix- ture. Before you perform any troubleshooting procedures read the following personnel and equipment safety precautions: 2) Wear hand and eye protection 3) Wait at least five minutes before accessing the lamp after operation If the procedures do not solve your problem and you need to call for assistance, please provide the support technician with the follow information:...
Page 16
DATA LINK (512 DMX) TROUBLESHOOTING rel. 7-0308...
MAIN BOARD CONNECTION U13 78M05 OPTO DMX PCB PAN IP LED DMX SIGNAL MOT3 MOT4 MAGENTA 7805 MOT2 INPUT TO CC250 MOT5 TO BASE FAN TO PCB CC250 rel. 7-0308...
Page 18
MOTORS BOARD Led flashing: the DMX signal is operating on the board Led off: check the U1 (6N137) and the DMX connecting cable (from PCB PAN IP) Switch on the fixture: 3b) If the motor is still not working check with extreme attention the motor and the interconnecting circuits (cables and connectors).
APPENDIX “A” CHANNEL FUNCTION DESCRIPTION DECIMAL PERCENT MOTOR SPEED SPEED MOVEMENT 0..63 0%..24% Slow Mid1 64..127 25%..50% Mid2 128..191 51%..74% 192..255 75%..100% Fast CYAN CONTINUOUSLY VARIABLE White Full color 100% YELLOW CONTINUOUSLY VARIABLE White 100% Full color MAGENTA CONTINUOUSLY VARIABLE White 100% Full color...
APPENDIX “B” PROGRAM FUNCTION Blue Cyan Magenta: color mix sequence (slow) Blue Cyan Magenta + White color mix sequence (slow) All colors: color mix sequence (slow) All colors + White color mix sequence (slow) All colors: color mix sequence (mid) All colors + White color mix sequence (mid) All colors + white color mix sequence (mid+) All colors - color mix sequence (mid+)
Page 36
Head Office: STUDIO DUE s.r.l. (I) Str. Poggino, 100 - 01100 Viterbo (Italy) tel. +39.0761.352520 fax +39.0761.352653 info@studiodue.com STUDIO DUE (UK) 3 Encon Court Owl Close Moulton Park Industrial Estate Northampton England UK - NN3 6 HZ tel. +44.1933.650.820 info@studiodue.co.uk...
Need help?
Do you have a question about the CITYCOLOR 2500 and is the answer not in the manual?
Questions and answers