Do you have a question about the RAM 100 and is the answer not in the manual?
Questions and answers
David Gaul
February 17, 2025
Where is the :Learn" or "Program" button on a Ramset model 100UL gate opener?
william shannon
March 8, 2025
how to install replacement motor
1 comments:
Mr. Anderson
March 8, 2025
To install a replacement motor for the RAMSET RAM 100:
1. Power Off – Disconnect the power supply to ensure safety. 2. Remove the Old Motor - Use the foot pedal release to disengage the gate from the motor. - Detach the motor from the chassis by removing the mounting bolts. - Disconnect the wiring from the control board. 3. Install the New Motor - Position the replacement motor (C-Face, 120 VAC, 1/2 HP) in place. - Secure it with the mounting bolts. - Connect the wiring as per the original configuration. 4. Reassemble and Test - Re-engage the gate with the motor. - Restore power and test the motor operation. - Ensure smooth and quiet functionality.
Follow all safety guidelines and do not exceed installation specifications.
• MAKE SURE TO ELIMINATE ANY PINCH POINTS ExISTING ON THE INSTALLATION. (ie. ROLLERS, ARMS…etc. ) • RAMSET GATE OPERATORS MUST BE INSTALLED BY A TRAINED TECHNICIAN. SAFETY DEvICES • REMOVE OR PROTECT ALL PINCH POINTS FROM THE GATE OPERATOR.
RAMSET IMPORTANT SAFETY REQUIREMENTS BY UL STANDARDS Prior to installation, the following must be g) The stop and/or reset button must be located in the line- observed: (per UL 325.56.8.4). of-sight of the gate. Activation of the reset control shall not cause the operator to start.
RAMSET CLASSES OF vEhICULAR GATE OPERATORS vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.
Do not exceed the specifications. The warranty on your unit will be void if the WARNING installation exceeds the recommended specifications. Note: Model RAM 100 Note: is designed to be Model RAM 1000 and RAM 5500 can be installed only for used for center and rear installation with front installations.
RAMSET RAM 100 INSTALLATION SPECIFICATIONS Do not exceed the specifications. The warranty on your unit will be void if the WARNING installation exceeds the recommended specifications. All Sliding Gate Operators are factory preset GATE for (LH) Left Hand Installations. Figure 1 CONCRETE PAD CONSTRUCTION 3”...
RAMSET RAM 100 FRONT INSTALLATION FRONT INSTALLATION Figure 4 GATE SHOWN Closed Tail on gate required TAIL WALL 13 7/8” 5 3/4” 6” min FOOT PEDAL RELEASE We do not recommend use of the foot pedal on installations with steep inclines. Always make sure the gate is secured when using the foot pedal to avoid sudden movements from the gate.
RAMSET RAM 1000/ RAM 5500 INSTALLATION SPECIFICATIONS Do not exceed the specifications. The warranty on your unit will be void if the WARNING installation exceeds the recommended specifications. All Sliding Gate Operators are factory preset Figure 6 for (LH) Left Hand Installations.
RAMSET LOOP SENSOR INSTALLATION Ramset Gate Operators should always be installed with non-contact sensing devices such as Loop Detectors, Photo Eyes or the equivalent. A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installation to comply with UL325.
RAMSET PUShBUTTON CONTROLS Three pushbuttons are located under the dip switches for operation of the gate (see Figure 15). The opening, stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator.
RAMSET DIP SWITCh CONFIGURATION DIP SWITCH “C” Dip Switch “C” 1; “SECURE CLOSE” Dip Switch “C” 5; “CLOSE DELAY” Function: One second delay on the closing of the gate. OFF Normal Operation Dip Switch “C” 6; “OPEN DELAY” When power is lost, then regained, control board checks status of the gate.
Page 16
RAMSET normal operation. If triggered twice before TERMINAL STRIP CONNECTIONS reaching a limit switch, the alarm will sound for Terminal # 1 - COMMON: 6 minutes and the control board will not accept Low voltage common. any commands. After the 6 minutes the 24 VDC is...
RAMSET RAMSET “INTELLIGATE” CONTROL BOARD Introduction: Ramset’s “Intelligate” Control Board works VAC and 220 VAC single-phase applications. with Sliding, Swinging and Overhead vehicular Some of the functions of the Control Board gate operators. It is controlled by a program- are: 0 - 60 seconds automatic close timer, self mable microprocessor that reads and precisely adjusting E.R.D.
Use with ILD-24s, Loop wires should be connected to this plug. jP4, jP5 & jP8 - Reverse, Exit & Phantom Sensor: Used with the Ramset ILD-24 plug-in loop detector. The Loop wires should be connected into the “LOOP INPUTS” plug. www.ramsetinc.com...
RAMSET GATE ENTRANCE SAFETY PRECAUTIONS WARNING Not following these instructions may cause severe injury or death to persons IMPORTANT SAFETY INSTRUCTIONS 1. Never let children operate or play with gate con- trols. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance.
E.R.D. and battery back warranty extension card. Return the warranty card, up systems. via certified mail, to Ramset within 90 days of purchase: Warning signs must be placed on every gate in a highly visible area.
1. Faulty accessory connected “REv LOOP” L.E.D. plug-ins, using the “Rev Loop” input. ALWAYS ‘ON’. to the “Rev Loop”. If problem persist, contact Ramset. 1. Check all transmitters. 1. Stuck button on Transmitter “RADIO” L.E.D. ALWAYS 2. Remove receiver. ‘ON’.
Page 26
9116 De Garmo Ave. Sun valley, CA 91352 tel: (818) 504-2533 • fax: (818) 504-1141 www.ramsetinc.com...
Need help?
Do you have a question about the RAM 100 and is the answer not in the manual?
Questions and answers
Where is the :Learn" or "Program" button on a Ramset model 100UL gate opener?
how to install replacement motor
To install a replacement motor for the RAMSET RAM 100:
1. Power Off – Disconnect the power supply to ensure safety.
2. Remove the Old Motor
- Use the foot pedal release to disengage the gate from the motor.
- Detach the motor from the chassis by removing the mounting bolts.
- Disconnect the wiring from the control board.
3. Install the New Motor
- Position the replacement motor (C-Face, 120 VAC, 1/2 HP) in place.
- Secure it with the mounting bolts.
- Connect the wiring as per the original configuration.
4. Reassemble and Test
- Re-engage the gate with the motor.
- Restore power and test the motor operation.
- Ensure smooth and quiet functionality.
Follow all safety guidelines and do not exceed installation specifications.