Printed Circuit Board) Exchange; Adjustment Volume Location; Test Point Location - Toshiba 50XP37C Service Manual

Plasma display
Hide thumbs Also See for 50XP37C:
Table of Contents

Advertisement

50XP37
8.3.
P.C.B. (Printed Circuit Board) exchange
8.3.1.
Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
8.3.2.
Quick adjustment after P.C.B. exchange
P.C.B.
P Board
SC Board
SS Board
D Board
*See the Panel label.
8.4.

Adjustment Volume Location

8.5.

Test Point Location

Name
Test Point
Vsus
TPVSUS (SS)
Vda
TPVDA (SS)
Vad
TPVAD (SC)
Vbk
TPVBK (SC)
Ve
TPVE (SS)
White blance
Voltage
Vsus* ± 2V
75V ± 1V
-85V ± 1V
140 ± 1V
Ve* ± 1V
SS3
SS3
– 12 –
Volume
Remarks
R641 (P)
R665 (P)
GND = chassis
R6477 (SC)
R6670 (SC)
R6770 (SS)