PRE-INSTALLATION REQUIREMENTS

Tools and Materials Required for Installation:

1. Phillips head screwdriver.
2. Channel-lock adjustable pliers.
3. Carpenter's level.
4. Flat or straight blade screwdriver.
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.2 cm) duct.
7. Vent hood.
8. Pipe thread sealer (Gas).
9. Plastic knife

ELECTRICAL REQUIREMENTS

ELECTRIC Dryer
CIRCUIT - Individual 30 amp. branch circuit fused with
30 amp. minimum time delay fuses or circuit breakers.
POWER SUPPLY - 3 or 4 wire, 240 volt, single phase,
60 Hz, Alternating Current.
POWER SUPPLY CORD KIT - The dryer MUST
employ a 3-conductor power supply cord NEMA 10-30
type SRDT rated at 240 volt AC minimum, 30 amp.,
with 3 open end spade lug connectors with upturned
ends or closed loop connectors or a 4-conductor power
supply cord NEMA 14-30 type SRDT or ST (as required)
rated at 240 volt AC minimum, 30 amp., with 4 open end
spade lug connectors with upturned ends or closed loop
connectors and marked for use with clothes dryers. If
being installed in a manufactured (mobile) home,
thedryer must employ a 4-conductor power supplycord
NEMA 14-30 type SRDT or ST (as required) rated at
240 volt AC minimum, 30 amp., with 4 open end spade
lug connectors with upturned ends or closed loop
connectors and marked for use with clothes dryers See
ELECTRICAL CONNECTIONS FOR for additional
instructions
OUTLET RECEPTACLE - NEMA 10-30R (3wire)
receptacle or NEMA 14-30R (4wire) receptacle to be
located so the power supply cord is accessible when
the dryer is in the installed position.
NEMA 10-30R
GAS Dryer
CIRCUIT - Individual 15 amp. branch circuit fused with a
15 amp. maximum time delay fuse or circuit breaker.
POWER SUPPLY - 3 wire, 120 volt single phase, 60 Hz,
Alternating Current.
POWER SUPPLY CORD - The dryer is equipped with a
120 volt 3-wire power cord.
NOTE: Do not under
any circumstances
remove grounding
prong from plug.

EXHAUST SYSTEM REQUIREMENTS

Use only 4 inch (10.2 cm) diameter (minimum) rigid or
flexible metal duct and approved vent hood which has
a swing-out damper(s) that open when the dryer is in
operation. When the dryer stops, the dampers
automatically close to prevent drafts and the entrance
of insects and rodents. To avoid restricting the outlet,
maintain a minimum of 12 inches (30.5 cm) clearance
between the vent hood and the ground or any other
obstruction.
The
requirements for proper and safe operation of your
dryer. Failure to follow these instructions can
create excessive drying times and fire hazards.
Do not use plastic flexible duct to exhaust the
dryer. Excessive lint can build up inside exhaust system
and create a fire hazard and restrict air flow. Restricted
air flow will increase dryer times. If your present system
is made up of plastic duct or metal foil duct, replace it
with a rigid or flexible metal duct. Ensure the present
duct is free of any lint prior to installing dryer duct.
28
NEMA 14-30R
GROUNDING PRONG