Table of Contents

Advertisement

Available languages

Available languages

WATERFORD SYSTEMS
HIGH RATE SAND FILTER SYSTEM
For Above Ground Swimming Pools
O
W
N
E
R ' S
M
A N
U
A L
839 0494
INSTALLATION, OPERATION & PARTS
This manual should be given to the end user of this system.
Pentair Water Pool and Spa, Inc.
© 2007 Pentair Water Pool and Spa, Inc. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
Pentair Water Pool and Spa logo are trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in
this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa Inc. disclaims pro-
prietary interest in marks and names of others.
Printed in U.S.A.
S260 (Rev. C)
04/18/2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HIGH-RATE SAND FILTER SYSTEM and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair Pool Products HIGH-RATE SAND FILTER SYSTEM

  • Page 1 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 Pentair Water Pool and Spa logo are trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa Inc. disclaims pro- prietary interest in marks and names of others.
  • Page 2: Table Of Contents

    HIGH-RATE SAND FILTER SYSTEM To avoid unneeded service calls, prevent possible injuries, and get the most out of your filter, READ THIS MANUAL CAREFULLY! The High Rate Sand Filter System: • Is designed to circulate and filter water in above ground swimming pools.
  • Page 3: Safety Instructions

    READ AND FOLLOW SAFETY INSTRUCTIONS! sional perform all pressure tests. This is the safety-alert symbol. When you see this symbol on your valve or in this manual, 1. Do not connect system to a high pressure or city look for one of the following signal words and be water system.
  • Page 4 TABLE I - OUTLINE DIMENSIONS IN INCHES (mm) Filter Model 15”(406mm) Filters 24 (610) 30-7/8 (784) 15-3/4 (400) 21-11/16 (551) 26-1/16 (662) 18”(457mm) Filters 26-9/16 (675) 33-5/16 (846) 17-3/4 (451) 24-1/4 (616) 27-1/16 (692) 21” (508mm) Filters 28-11/16 (729) 34-7/16 (875) 20-3/4 (527) 26-3/8 (670) 28-9/16 (725)
  • Page 5: General Information

    water level at all times. This allows pump to prime. GENERAL INFORMATION • Have adequate ventilation to prevent motor • Clean a new pool as well as possible before filling overheating. pool and operating filter. Excess dirt and large parti- Piping: cles of foreign matter in the system can cause seri- ous damage to the filter and pump.
  • Page 6: Loading Sand Media

    access for filter maintenance. Valve port labeled Filter Setup “PUMP” should point toward pump. Assembly: See Figures 2 through 5 for filter assembly. 4. Tighten clamp knob until clamp ends (under bolt) are 1/4" (6mm) apart. Tap around outside of clamp with Loading Sand Media a mallet to help seat clamp.
  • Page 7: Electrical

    Follow directions under “Valve In stallation”, Page 6, ELECTRICAL when reinstalling valve. See Figures 6 and 7. Risk of electrical shock. Plug pump into a grounded, GFCI-protected 115 Volt circuit only. Incorrect volt- age can cause fire or seriously damage motor and voids war- ranty.
  • Page 8: Startup/Operation/Backwash

    Startup/Operation (See Figure 9) Dist. In Ft. (m) (Serv. To Motor) Motor Nameplate Branch Volts/Hz/ 0-100' 101-200' 201-300' Temp Hazardous suction. Can trap and tear Rating- ◦ C Full Load Amps Circuit Phase (0-30) (31-60) (61-90) hair or body parts and can cause drowning. Do not block pump suction.
  • Page 9: Maintenance

    MAINTENANCE Hazardous pressure. To avoid explo- sion and possible severe or fatal injury, filter sys- General: tem pressure must not exceed 50 PSI (345 kPa) • Wash outside of filter with a mild detergent and water. under any circumstances. NEVER test this filter Rinse off with hose.
  • Page 10: Storage/Winterizing

    STORAGE/ Drain Fitting Installation/Removal WINTERIZING NOTICE: If pool is above height of filter, first close valves in pump suction and return lines to prevent Pool chemicals may give off corrosive draining pool. If there are no shutoff valves installed, fumes. Store chemicals away from system in a well disconnect suction and return lines and raise ends ventilated area.
  • Page 11: Multi-Port Valve Service

    3. Remove valve from filter top. MULTI-PORT VALVE SERVICE 4. To reinstall valve, follow “Valve installation” instruc- Hazardous pressure. Stop pump and tions, Page 6. BE SURE to follow clamp tightening release all pressure from system before working on instructions. filter, valve, or clamp.
  • Page 12 Make sure seal is firmly and evenly seated. To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before work- 4.Install rotating half of seal on impeller sleeve. Push ing on pump or motor. it onto sleeve until it butts against back of impeller. Trap needs no lubrication or regular maintenance be- 5.Insert impeller sleeve through center hole in seal yond reasonable care and periodic cleaning of strainer...
  • Page 13: Troubleshooting Guide

    TROUBLESHOOTING GUIDE – TROUBLESHOOTING GUIDE – PUMP FILTER Read and understand safety and operating in- A. Short Cycle between backwashes: structions in this manual before doing any NOTICE: Time between backwashes will vary with work on pump. each installation and between different areas of the A.
  • Page 14 1277 0994 Repair Parts List - Filter MODELS No. JSAL15 Series JSAL18 Series JSAL21 Series Part Description Used 15” Filter 18” Filter 21” Filter Pump* (Models with -06, -09 suffix) JWP Series JWP Series JWP Series Pump** (All other suffixes) JWP Series JWP Series JWP Series...
  • Page 15: Repair Parts List

    REPAIR PARTS LIST POOL PUMPS 3/4 thru 1-1/2 HP Single Speed 1 Hp Dual Speed NOTICE: AT23 series models use the same front plate and seal plate as other models; however, they are rotated 90° counter-clockwise when installed. Part Description Qty.
  • Page 16 JWPA PUMPS 381 1293 CORD AND PLUG PART NUMBERS -2A2 Models -2A1 Models -A2U Models -2A4U Models Cord Ass’y with Cord Ass’y with Cord Ass’y with Twist-lock Plug Straight Plug Straight Plug 2A1, 6A1 Models 2A, 2A2, 6A2 Models 2A4 Models –...
  • Page 17 REPAIR PARTS LIST WC112-148A MULTIPORT VALVE Aquatools .WATERFORD, WI. 53185 Part Description Qty. Number Decal, Valve Handle 32145-4016 Handle 14962-0032 Dowel Pin 35857-0021 Washer 14965-0007 Decal, Operating Instructions 14965-0020 Screw 37067-0714 Valve Cover 14965-0011 O-Ring 35505-1228 Washer 14965-0007 Washer 14965-0007 Spring 14965-0006 Pressure Gage...
  • Page 18 For technical information about this product, contact the installer or call PENTAIR at (800) 831-7133. Visit www.pentairpool.com and www.staritepool.com 01/31/2007 S260 (Rev.A)
  • Page 19 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 Pentair Water Pool and Spa logo are trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa Inc. disclaims pro- prietary interest in marks and names of others.
  • Page 20 SYSTÈME DE FILTRATION À SABLE À GRAND DÉBIT Pour éviter les appels inutiles d'un réparateur, éviter toutes blessures possibles et obtenir le meilleur rendement de ce système de filtration, LIRE ATTENTIVEMENT CETTE NOTICE! Le système de filtration à sable à grand débit Aquatools : •...
  • Page 21: Consignes De Sécurité

    LIRE ET OBSERVER CES CONSIGNES DE SÉCURITÉ! staller et faire fonctionner l'équipement. Demander à un pro- Ce symbole indique qu'il faut être prudent. Lorsque ce fessionnel qualifié en piscines de procéder à tous les con- symbole apparaît sur la vanne ou dans cette Notice, trôles de pression.
  • Page 22 TABLEAU I - DIMENSIONS EXTÉRIEURES EN POUCES (mm) Modèle de filtres Filtres de 406 mm (15 pouces) 24 (610) 30-7/8 (784) 15-3/4 (400) 21-11/16 (551) 26-1/16 (662) Filtres de 457 mm (18 pouces) 26-9/16 (675) 33-5/16 (846) 17-3/4 (451) 24-1/4 (616) 27-1/16 (692) Filtres de 508 mm (21 pouces) 28-11/16 (729)
  • Page 23: Renseignements Généraux

    • offrir une ventilation adéquate pour empêcher au moteur RENSEIGNEMENTS de surchauffer. GÉNÉRAUX Conduites : • Si la piscine est neuve, la nettoyer le mieux possible avant • Utiliser du ruban Téflon ou du Plasto-Joint Stik sur tous les de la remplir et de faire fonctionner le filtre. Le filtre et la raccordements mâles des raccords et les tuyaux en plas- pompe risquent d'être sérieusement endommagés si le tique, sauf sur les raccords unions.
  • Page 24: Montage Du Filtre

    «PUMP» doit être orienté vers la pompe. Montage du filtre 4. Serrer le bouton du collier jusqu'à ce que les deux ex- Assemblage : Voir les Figures 2 à 5 pour l'assemblage du fil- trémités du collier (sous la vis) soient à 6 mm (1/4 de po) tre.
  • Page 25: Électricité

    7. Terminer tous les raccords de la plomberie (se rapporter à ÉLECTRICITÉ la page 5 pour les conduites à utiliser). Risque de secousses élec- A. Le tuyau de l'orifice RETOUR (RETURN) de la vanne AVERTISSEMENT triques. Ne brancher la doit être orienté vers le retour de la piscine. pompe que sur un circuit ali- B.
  • Page 26 Mise en service/fonctionnement (Voir la Lointain dans Ft. (meteres) (Serv. to au moteur) Figure 9) La Plaque Moteur de Nom Aspiration dangereuse. Des parties du Chargement Plein Branche Volts/Hz/ 0-100' 101-200' 201-300' Temp Rating- ◦ C corps ou les cheveux peuvent être aspirés Amplis Circuit Phase...
  • Page 27: Entretien

    Pression dangereuse. Pour éviter une ENTRETIEN explosion et des blessures graves pos- Généralités: sibles, voire mortelles, la pression du système de filtra- tion ne doit jamais dépasser 345 kPa (50 lb/pi ). NE • Laver l'extérieur du filtre avec un détergent doux et de JAMAIS contrôler ce système de filtration à...
  • Page 28: Entreposage Et Préparation Pour L'hiver

    Dépose/repose du raccord de vidange ENTREPOSAGE ET NOTA: Si la piscine est à plus de huit pieds au-dessus du fil- PRÉPARATION POUR tre, fermer tout d'abord les robinets des conduites de retour L'HIVER et d'aspiration de la pompe pour empêcher de vider la piscine.
  • Page 29: Entretien Des Vannes À Orifices Multiples

    ENTRETIEN DES VANNES À ORIFICES MULTI- piscine. PLES 2. Déposer le collier. 3. Déposer la vanne du filtre. Pression dangereuse. Arrêter la pompe 4. Pour reposer la vanne, suivre les instructions «Installation et dissiper toute la pression du système de la vanne» à la page 6. S'ASSURER de respecter les in- avant d'intervenir sur le filtre, la vanne ou le collier.
  • Page 30 15 et 16) à la recherche de rayures, d'entailles, etc. et voir Pour éviter tout risque de secousses électriques si le ressort ou le flasque n'est pas endommagé. Le rem- dangereuses ou mortelles, INTERROMPRE l'arrivée placer si des signes d'usure ou de dommages sont visi- de courant parvenant au moteur avant d'intervenir sur la bles.
  • Page 31: Guide De Diagnostic Des Pannes

    GUIDE DE DIAGNOSTIC GUIDE DE DIAGNOSTIC DES PANNES DE LA DES PANNES DU FILTRE POMPE A. Intervalles de fonctionnement courts entre les lavages à contre-courant : Avant de procéder à toute intervention sur cette NOTA: L'intervalle entre les lavages varie avec chaque in- pompe, bien lire et bien comprendre toutes les con- stallation et selon les régions du pays.
  • Page 32 1277 0994 Liste des pièces de rechange - Filtre MODELES JSAL15 Sèrie JSAL18 Sèrie JSAL21 Sèrie Réf. Désignation des pièces Qté. 15” Filtre 18” Filtre 21” Filtre Pompe* (Modèles précédés du préfixe -06, -09) JWP Sèrie JWP Sèrie JWP Sèrie Pompe** (Tous les autres suffixes) JWP Sèrie JWP Sèrie...
  • Page 33: Liste Des Pièces De Rechange

    LISTE DES PIÈCES DE RECHANGE POMPES POUR PISCINES Modèles de 3/4 à 1-1/2 ch, Une Vitesse 1 ch, Deux Vitesses NOTICE: AT23 series models use the same front plate and seal plate as other models; however, they are rotated 90° counter-clockwise when installed.
  • Page 34 POMPES JWPA 381 1293 NUMÉROS DE PIÈCE DES CORDONS ÉLECTRIQUES ET DES FICHES Modèles -2A2 Modèles -2A1 Modèles -A2U Modèles -2A4U Modèles -2A Cordon électrique avec fiche Cordon électrique Cordon électrique Modèles -2A1 Modèles -2A2 à verrouillage par rotation avec fiche droite avec fiche droite Modèles -6A1 Modèles -6A2...
  • Page 35 LISTE DES PIÈCES DE RECHANGE - VANNE À ORFICES MULTIPLES Modèle WC112-148A Réf. Désignation Qté. N° des pièces Décalcomanie – Poignée Aquatools .WATERFORD, WI. 53185 de la vanne 32145-4016 Poignée 14962-0032 Goupille d'immobilisation 35857-0021 Rondelle 14965-0007 Décalcomanie – Instructions de fonctionnement 14965-0020 37067-0714 Couvercle de la vanne...
  • Page 36 Pour obtenir les données techniques du produit, communiquez avec l’installateur ou appelez PENTAIR au numéro (800) 831-7133. Visitez notre site Web : www.pentairpool.com www.staritepool.com 01/31/2007 S260 (Rev.A)

This manual is also suitable for:

Waterford systems high rate sand filter system

Table of Contents