Fault Codes - Heatline CaprizPlus 24 G.C. No. 47-157-19 Installation And Servicing Manual

High efficiency condensing combination boilers
Table of Contents

Advertisement

Fault
Description
codes
F00
Flow heating temperature sensor fault
F01
Return heating temperature sensor fault
F10
Flow heating temperature sensor fault
F11
Return heating temperature sensor fault
F20
Overheating fault
F22
Water pressure of the installation (<0.3 bar)
Maximum temperature difference reached
F23
between return and fl ow heating
F24
Water circulation fault
F26
Fault in gas valve motor.
F27
Flame detection fault.
F28
Ignition fault
F29
Loss of fl ame during operation
F32
Incorrect air pressure
F49
EBUS voltage fault
F61
F62
F63
Fault in the main board
F64
F65
F67
F68
Fluctuation of fl ame signal
User interface incompatible with the main
F70
board
F71
Flow heating temperature sensor fault
Permanent temperature difference between
F72
fl ow and return heating sensors
- 30 -
Cause
Sensor open circuit
Return heating temperature sensor
disconnected
Sensor short-circuit
Return heating temperature sensor
shorted.
Overheating safety device activated
(97°C)
Return water valve closed
Pump disconnected
Leak in the installation
Water circulation fault
Malfunction of the pump (excessively
rapid temperature increase)
Disconnected or defective cables
Abnormal fl ame detection
No return gas / Insuffi cient gas fl ow
Gas valve incorrectly adjusted
Defective fi ring electrode and fl ame
control / Defective igniter unit
Incorrect fan speed.
Fault in EBUS line
Short circuit in EBUS connector
Gas valve command fault
Gas valve closure fault
Fault in the main board memory
Rapid fl uctuation of return or fl ow
heating sensor.
Excessive main board temperature
Flame signal fault in the main board
No return gas / Insuffi cient gas fl ow
Gas valve incorrectly adjusted
Defective fi ring electrode and fl ame
control / Defective igniter unit
Incorrect product code
Flow heating temperature sensor
unclipped or defective (no
temperature variation)
Mismatch between the fl ow and return
heating temperatures (permanent
difference)
Service Call 0844 736 9138, Technical Help (Chargeable) Call 0906 802 0253
Solution
• Check the sensor's connections.
• Check the wiring harness.
• Check the sensor.
• Check the operation of the pump.
• Check the wiring harness.
• Check that the fl ow and return heating isolation
valves are open.
• Fill the installation.
• Purge the installation.
• Check the pump connections.
• Check the fl ow and return heating sensor
connections.
• Check that there are no leaks.
• Check the fl ow and return heating sensor
connection.
• Check the pump speed.
• Check that the fl ow and return heating isolation
valves are open.
• Check the gas valve connections.
• Check the operation of the gas valve.
• Check the operation of the condensate pump (option).
• Check the fl ame detection electrode.
• Check the main board.
• Check the igniter unit.
• Check the return gas circuit (gas valve open).
• Check the observe the fl ame picture and check
the CO
setting.
2
• Check the igniter unit connections.
• Check the state of the electrode (corrosion).
• Check the entire fl ue system.
• Check the fan's electrical connections.
• Check that the eBus controls are fi tted and wired
correctly.
• Check the main boards connections.
• Check the main board.
• Check the appliance DSN number is correct.
• Reset the appliance.
• Check the return gas circuit (gas valve open).
• Check the observe the fl ame picture and check
the CO
setting.
2
• Check the igniter unit connections.
• Check the state of the electrode (corrosion).
• Check that the appliance DSN code on the screen
matches the product code of the nameplate (in the
event of a fault and the appliance DSN does not
appear, consult menu.d.93 reserved for the code).
• Check the boards reference.
• Check the sensor connections.
• Make sure that the sensor is clipped to the tube.
• Check temperature sensors connections.
• Replace faulty sensors.