4 Functions of NBManager
4-6

Decompile Operation

Decompile Operation:

Convert PKG file to the format which can be handled with the NB-Designer.
Note When the multiple PTs are registered in a project, all the PKG files of PTs registered in the project are nec-
essary to be prepared.
1
Select .pkg files.
2
Set the folder of "Select Target Project Folder to Decompile".
3
Click the [Decompile] button and input the decompile password, then click the OK button. When
the decomplie is completed, "Decompilation success!" dialog box will pop up.
The prerequisite for the decompile operation is "Allow Decompilation" is checked and the pass-
word is set in the [PT Extended Properties] tab during the project creation. The default decompi-
lation password is 888888.
4-16