Flash code
Fault
8
Motor voltage error
9
Miscellaneous internal fault
10
Push/freewheel mode error

10.2 Resetting the circuit breaker

WARNING!
– NEVER defeat or bypass the circuit breaker.
– ONLY replace with a circuit breaker of the same
rating.
– Key must be removed from ignition before resetting
circuit breaker.
– Resetting the circuit breaker may be needed if the
scooter does not turn on and the reset button has
popped out about 6 mm.
1576371-B
Consequence for the
scooter
Comments
Stops driving
Stops driving
Stops moving
1.
To reset, press the circuit breaker button A located on the
front of the battery box.
The motor or its cabling is defective Check the cabling for
open or short-circuited circuitry.
Contact your Invacare dealer.
The scooter has exceeded the permissible maximum speed
during pushing or freewheeling. Switch the electronics system
off and on again.