Preparations (Step 1 Connection and Installation)
Cable Connections (continued)
4. Connecting Coaxial cable
Connecting a RG-59 coaxial cable.
Note
Fold back the mesh wires and secure them
with insulation tape in order to prevent them
from becoming loose and thus causing a
short circuit.
Polyethylene
Conductor
wire
7
(5)
Insulation tape
Provided cable
plate
16
Mesh wires
17
(12)
Provided screw
Screw removed in
the figure on the left
If the cable is extended, the signal attenuation is
increased, the resolution drops and the noise in-
creases. Should it be required to extend the cable,
use a thicker cable or a cable length compensa-
tor.
Note
The figures inside the brackets ( ) are the
dimensions when the coaxial cable is dis-
tributed from the side of the cover.
(Unit : mm)
To feed the coaxial cable through the cap on the
side of the cover, change the positioning of the
cable plate as shown below.