Index Installation Instructions Product specifi cation and Installation Installation and Wiring DIL switch settings Advanced Programming Options Copy Functions Service Interval Timer Wiring Conversion 8-15 User Instructions What is a Programmer? Your programmer Preset programmes Resetting the unit 24hr or AM/PM display Setting the Date, Time and Day 18-19 Accepting the preset programmes...
Installation Instructions Please Note: This product should only be installed by a qualifi ed electrician or competent heating installer, and should be in accordance with the current edition of the IEEE wiring regulations. Product specifi cation Specifi cation 230V model 24V model Power supply 230 Vac,...
Page 4
For wiring connections refer to diagram below. ESKIT models are double insulated and do not require an earth connection, however a parking terminal is provided on the wallplate. This is clearly marked with an Earth symbol.
DIL Switch Settings Before mounting the unit, ensure the Sw.1 Not Used Not Used 4 DIL switches on the rear have been Sw.2 Gravity Pumped 5/2 Day 7 Day or 24 Hour Sw.3 moved to the required settings. Sw.4 7 Day 24 Hour Tick the INSTALLER SETTING box on the inside fl ap label to notify...
Copy Functions Explained There are 3 possible copy functions available. These are; Standard Copy, Enhanced Copy, and AB copy. Copy functions are enabled/disabled in the Advanced Programming Options (page 5). Standard Copy: Pressing copy will copy the previous days events into the displayed day. The unit will then display the 1st event for the new day.
Programme “B” day events using the + (time advance), - (time decrease), and NEXT (next period) buttons. Service Interval Timer The ESKIT is fi tted with an installer setback service interval timer. If this feature is required please contact our technical department. Setting instructions for this gas safety feature are...
(applies only to 230 volt models) Wiring conversions can be used when replacing the following programmers with the ESKIT. Some time controls are connected diff erently depending on the type of system they are controlling. Consult the column headed “NOTE This conversion ...
Page 9
Table B (pages 12-15) should be used. If in any doubt, contact our Technical Services Department before proceeding with the replacement. *Any wires connected to switch COMMONS which are linked LIVE on existing wallplates must be transferred to the LIVE terminal on the new wallplate An additional terminal Wires other block may be required...
Page 11
An additional terminal Wires other block may be required than links in NOTE where these discon- these terms This conversion applies nected leads (or pairs) go to LIVE only if..should be terminated Programme selectors UNLINKED Programme selectors UNLINKED Used in a system having independent control of water and heating...
Page 13
An additional terminal Wires other block may be required than links in NOTE where these disconnected these terms to This conversion leads (or pairs) should be LIVE applies only if..terminated Programmed selectors UNLINKED OILER STAT Programme selectors UNLINKED Programme selectors UNLINKED ...set for gravity HW Programme...
Page 15
An additional terminal Wires other block may be required than links in NOTE where these discon- these terms This conversion nected leads (or pairs) to LIVE applies only if..should be terminated Programme selectors UNLINKED L & 4 are LINKED Programme selectors UNLINKED Used in a system having...
The text below has been edited and approved by the Plain English Campaign, who has issued a Crystal Mark to be displayed with it. What is a programmer? ... an explanation for householders. Programmers allow you to set ‘On’ and ‘Off ’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at...
User Instructions Your programmer The ESKIT allows you to switch your heating and hot water on and off at times that suit you. Your programmer has had the date and time set up during manufacture and will automatically change between Greenwich Mean Time and British Summer Time.
Before you start Open the fl ap on the front of the clock. Press the RESET button using a non-metallic object (e.g. pencil/matchstick) until you hear a click and the 2 red lights on the front of the unit fl ash once.
Press DAY/HOL to display day and month. Use the + or - buttons to set the correct month (Jan = 1, Feb = 2 etc.). Press DAY/HOL to display day and month. Use the + or - buttons to set day of month.
Before you change the preset programmes Your installer will have set your unit to operate in one of the following modes: 5/2 day - one set of programmes for weekdays and another for weekends (page 21-22) 7 day - diff erent settings for each day of the week. (page 23-24) 24 hour - one set of programmes for the whole week.
Page 21
Programming the heating in 5/2 day mode Press PROG once until SET CH DAY/HOL ON TIME appears at the top of the display and MOTUWETHFR appears at the bottom of the display. Use the + or - buttons to set the time you would like your heating to fi rst come on in the morning (Event 1).
Page 22
Press the DAY/HOL button once DAY/HOL and SASU will appear at the bottom of the display. If the same programme is DAY/HOL required press COPY button and the previous days programme will be entered. If a diff erent programme is required repeat steps 2-4.
Programming the heating in 7 day mode Press PROG once until SET CH DAY/HOL ON TIME appears at the top of the display. Note the current day is displayed. Press the DAY/HOL button until the required day is displayed. Use the + OR - buttons to set the time you want your heating to fi rst come on in the morning (Event 1).
Page 24
Press the PROG twice button to return the unit to RUN mode DAY/HOL (time appears & colon in the display begins to fl ash). Proceed to page 27.
Programming the heating in 24 hour mode Press PROG once until SET CH DAY/HOL ON TIME appears at the top of the display. Use the + OR - buttons to set the time you want your heating to fi rst come on in the morning (Event 1).
Programming the hot water To set the hot water programme DAY/HOL press the PROG button twice until SET HW ON TIME appears on the display. Set the hot water programme in the same way as the heating programme, using: DAY/HOL + and - buttons to alter the time, Pressing the NEXT ON/OFF...
Running your Programme To run the central heating programme: press the SELECT button next to the radiator symbol until AUTO is displayed in the LCD. To run the hot water programme: press the SELECT button next to the tap symbol until AUTO is displayed in the LCD.
Temporary override buttons Sometimes you may need to change the way you use your heating temporarily, i.e. due to unusually cold weather. The ESKIT has two convenient overrides which can be selected without aff ecting the set programme. +1HR +1HR...
Holiday Programme To automatically bring the heating back on when returning from holiday the ESKIT has a built in holiday feature. Follow the steps below to set the date that the heating system needs to come back on. Press DAY/HOL...
Changing clocks forward & back This is handled automatically. Should the installer have turned off Automatic Time Change then follow the instructions below. Open the fl ap on the front of the unit to reveal the programming buttons. To change from Summer to Winter (clocks back) - press and hold - button To change from Winter to Summer...
Service Interval Timer If the property is owned by a landlord he may, for gas safety reasons, have instructed the installer to set the service interval timer. If set, 28 days prior to the boiler service due date, a momentary visual and audible warning will remind you to have the boiler serviced in the next 28 days.
Making a Full Reset If it is necessary to fully reset the unit, excluding the date and time, follow the instructions below. Press and hold the +1HR and MAN buttons on the left hand side of the product. +1HR +1HR Press the RESET button and hold for 3 seconds.
Fault Check List o Hot Water heck FP715 programmer. Turn the heating selector to OFF and the water selector to ON. Is the red light by the water switch on? heck fuse in fused spur heck cylinder thermostat Is the stat set to a temperature of 60° ? Turn knob to 60°...