RANGE HOOD INSTALLATION INSTRUCTIONS
ALL HOODS MUST BE INSTALLED BY A QUALIFIED INSTALLER OR SERVICE AGENCY
WARNING - TO REDUCE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSON, OBSERVE
THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all appli-
cable codes and standards, including fire-rated construction. Switch power off at service panel and lock
the service disconnection means to prevent power from being switched on accidentally during installa-
tion.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
C. All hoods must always exhaust to the outdoors.
D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent back drafting. Local building codes may require the use of make-up
air. Consult your local HVAC professional for specific requirements in your area. Follow the heating
equipment manufacturer's guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and state, municipal and local code authorities. The correct voltage, fre-
quency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or time delay fuse.
E. Warning - To reduce risk of fire, use only metal ductwork.
F. Use this unit in the manner intended by the manufacturer. If you have questions, contact the manufac-
turer.
INSTALLER: Please retain these instructions for reference, then leave them with the homeowner.
HOMEOWNER: please read and keep the instructions for future reference.
If you have questions concerning the installation of this product, call ABBAKA at (800) 548-3932.
ABBAKA Hoods Using Hy-Ex Remote Ventilators
PLEASE READ & SAVE THESE INSTRUCTIONS
Tel. (800) 548-3932 - Fax (800) 548-3930 - webmail@abbaka.com
P.O. Box 215, Bodega Bay, CA 94954
www.abbaka.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Range Hood & Hy-Ex Ventilation System and is the answer not in the manual?

Questions and answers

Summary of Contents for ABBAKA Range Hood & Hy-Ex Ventilation System

  • Page 1 RANGE HOOD INSTALLATION INSTRUCTIONS ABBAKA Hoods Using Hy-Ex Remote Ventilators PLEASE READ & SAVE THESE INSTRUCTIONS ALL HOODS MUST BE INSTALLED BY A QUALIFIED INSTALLER OR SERVICE AGENCY WARNING - TO REDUCE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSON, OBSERVE THE FOLLOWING: A.
  • Page 2 Range Hood & Hy-Ex Ventilation System Installation Instructions Contents Warnings .................... 1 Unpacking and Planning ..............3 Pre-Installation Preparation Ducting ..................4-5 Electrical ..................6 Mounting..................7-8 Liner Re-Install and System Testing ..........9 Care Instructions ................10 Warranty Information................ 11 www.abbaka.com Tel.
  • Page 3 Unpacking and Preparation WARNING: HOOD SURFACE SENSITIVE TO SCRATCHING DO NOT LIFT HOOD BY RAILS ABBAKA range hoods consist of the hood shell and a liner, which fits into the base of the hood shell and houses the lighting, filters and controls. 1.
  • Page 4 Hy-Ex Professional Exterior Ventilator Correct Ducting and Venting Use proper sized smooth galvanized ductwork- Hy-Ex 1.4 (1400 CFM) 10” round; Hy-Ex 1.0 (1000 CFM) 8” round Do not use flexible duct. Ribbing creates resistance to airflow, reducing exhaust efficiency. Do not space elbows closer than 4’ to each other. Do not make "S"...
  • Page 5 Ducting Hy-Ex Ventilator - Exterior Venting Hy-Ex Remote Ventilator Proper ductwork installation will al- low ventilator to efficiently move air from hood to outside the building. Use smooth galvanized ductwork with a minimum num- ber of elbows and bends. All joints must be sealed and run upstream.
  • Page 6 Electrical/Liner Installation Hoods Using Hy-Ex Remote Ventilator NOTE: Make all connections in accordance with local codes. Switch power off at service panel and lock the service discon- necting means before wiring the unit. Detailed instructions Hy-Ex Remote Ventilator for electrical connection to the remote ventilator will be pack- aged with the ventilator.
  • Page 7 Hanging Wall Mounted Hoods Ceiling 1. Protect the cooktop with a furniture pad or consider building a worktop straddling the counter. Center Wall Stud and square the hood to the actual location of cook- Upper Wall top. Lift in straight line to ceiling and trace outline of Attachment stack onto ceiling.
  • Page 8 Hanging Island Hoods Hanging Frame 1. Protect the cooktop with a furniture pad or con- 2 x 4 Frame for sider building a worktop straddling the counter. Hood Stack Center and square hood to actual location of cooktop. Leading edge of hood should align with front cooking element, NOT front of cooktop.
  • Page 9 Wiring At Hood/Liner Re-Installation & Wiring At the Hood: System Testing Position hood liner on counter below hood. Remove Light /Switch Control Panel and Light Only Panel (or Screw Covering Panel in wall mount hood) from liner (see Figure A). Feed conduit from ventilator into knock out Typical Island labeled “Ventilator Switch Leg”...
  • Page 10 Care Instructions CARE OF YOUR COPPER OR BRASS RANGE HOOD Pure copper or brass, polished to a mirror finish, is used in the fabrication of your ABBAKA Range hood of semiprecious metal. The optional utensil rail and “S” hooks are like wise made of pure mirror- polished brass.
  • Page 11 Care Instructions / Warranty CARE OF YOUR ANTIQUE COPPER OR ANTIQUE BRONZE RANGE HOOD Pure copper or brass is used in the fabrication of your "Antiqued" ABBAKA Range hood. The optional utensil rail and "S" hooks are likewise made of pure brass. These exotic metals are then chemi- cally aged to create a classic distressed look.