Using the VC6000 Series Indoor

When using the VC6000 Series indoor, the VC6000 Series can be placed on a desk and powered using an Indoor
Power Supply Unit.
To connect the VC6000 Series indoor (see
Connect a ground wire between the VC6000 Series and the facility ground system.
1.
!
WARNING
The ground wire ring lugs should be connected to the Ground Point (GND) at the back of the VC6000 Series
using M4 screw.
Mount the Combination Antenna outdoor. Contact the mast of the antenna, by a metal bonding, to a ground
2.
wire that runs directly into the earth, via a deep ground rod. For antenna installation guidelines, (see Mounting
the Combination Antenna (VC6096 only) on page 2-10).
!
WARNING
Keep a minimum lateral distance of 20 cm (8 inches) between the VC6000 Series user and the antenna. Contact
your professional installer, VAR, or antenna manufacturer for proper installation requirements.
Connect the WWAN plug of the Combination Antenna cable to the WWAN antenna connector at the back of
3.
the VC6000 Series (VC6096 only). Rotate clockwise to fasten the connector.
Connect the WLAN plug of the Combination Antenna cable to the WLAN antenna connector at the back of the
4.
VC6000 Series (VC6096 only). Rotate counterclockwise to fasten the connector.
Attach the 12 V DC cable of the Indoor Power Supply Unit to the Power Connector at the back of the VC6000
5.
Series and turn clockwise to lock. Rotate clockwise to lock the connector.
Connect the AC Cord into the Indoor Power Supply Unit.
6.
Connect the AC Cord plug into a 100-240 V AC / 50-60 Hz power outlet.
7.
AC Cord
12 V DC Cable
Desktop Power Supply Connection
Figure 2-12
NOTE The total length of the power supply cables is 14.1 ft (4.3 m).
Figure
To ensure proper grounding, use a 18AWG ground wire between the VC6000 Series Ground
Point (GND) and the facility ground system.
Indoor Power Supply Unit
For indoor use only in dry locations
Power Connector
WWAN Antenna Connector
2-12):
WLAN Antenna Connector
Installation 2 - 13
Ground Point
GND