13.0 RETURNING PRODUCTS FOR REPAIR
Before returning the unit for repair, please contact a Setra application engineer (800-257-3872,
978-263-1400) to review information relative to your application . Many times only minor field
adjustments may be necessary. When returning a product to Setra, the unit should be carefully
packaged and shipped prepaid to:
Setra Systems, Inc.
159 Swanson Road
Boxborough, MA 01719-1304
Attn: Repair Department
To assure prompt handling, please refer to return instructions on our Web site at
http://www.setra.com/tra/repairs/cal_rep.htm.
Allow approximately 3 weeks after receipt at Setra for the repair and return of the unit.
Non-warranty repairs will not be made without customer approval and a purchase order to
cover repair charges.
Calibration Services
Setra maintains a complete calibration facility that is traceable to the National Institute of
Standards & Technology (NIST). If you would like to recalibrate or recertify your Setra pressure
transducers or transmitters, please call our Repair Department at 800-257-3872 (978-263-1400)
for scheduling.
14.0 WARRANTY AND LIMITATIONS OF LIABILITY
Setra warrants its products to be free from defects in materials and workmanship, subject to the
following terms and conditions:
Without charge, Setra will repair or replace products to be found to be defective in materials or
workmanship within the warranty period; provided that:
a.) the product has not been subjected to abuse, neglect, accident, incorrect wiring not our own,
improper installation or servicing, or use in violation of instructions furnished by Setra;
b.) the product has not been repaired or altered by anyone except SETRA or its authorized service
agencies;
c)the serial number or product code has not been removed, defaced, or otherwise changed; and
d) examination discloses, in the judgement of SETRA, the defect in materials or workmanship
developed under normal installation, use and service;
e) SETRA is notified in advance of and the product is returned to SETRA transportation prepaid.
Unless otherwise specified in a manual or warranty card, or agreed to in a writing signed by a SETRA
officer, SETRA pressure and acceleration products shall be warranted for one year from date of sale.
The foregoing warranty is in lieu of all warranties, express, implied or statutory, including but not
limited to, any implied warranty of merchantability for a particular purpose.
SETRA's liability for breach of warranty is limited to repair or replacement, or if the goods cannot
be repaired or replaced, to a refund of the purchase price. SETRA's liability for all other breaches is
limited to a refund of the purchase price. In no instance shall SETRA be liable for incidental or conse-
quential damages arising from a breach of warranty, or from the use or installation of its products.
No representative or person is authorized to give any warranty other than as set out above or to
assume for SETRA any other liability in connection with the sale of its products.
159 Swanson Road, Boxborough, MA 01719,
159 Swanson Road, Boxborough, MA 01719,
Tel: 800-257-3872; Fax: 978-264-0292;
Tel: 800-257-3872; Fax: 978-264-0292;
Email: sales@setra.com; Web: www.setra.com
Email: sales@setra.com; Web: www.setra.com
28
SS-SRPM Rev. B 9/2/2008
Model SRPM
Room Pressure Monitor
Installation and Operating Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRPM and is the answer not in the manual?

Questions and answers

Summary of Contents for Setra Systems SRPM

  • Page 1 SETRA any other liability in connection with the sale of its products. 159 Swanson Road, Boxborough, MA 01719, 159 Swanson Road, Boxborough, MA 01719, Tel: 800-257-3872; Fax: 978-264-0292; Tel: 800-257-3872; Fax: 978-264-0292; Email: sales@setra.com; Web: www.setra.com Email: sales@setra.com; Web: www.setra.com SS-SRPM Rev. B 9/2/2008...
  • Page 2: Table Of Contents

    1.2 SRPM Function ............................. 5 VAC to 265 VAC, 50 Hz or 60 Hz 2.0 Parts List .......................6 1.1 SRPM Parts List ............................. 6 All the internal supply voltages are generated using the Switching 1.2 Model SRAN (Option) Parts List...................... 6 Mode Power Supply (SMPS).
  • Page 3 10.0 Agency Electrical Standards..............25 Storage °F (°C) -20 to +160 (-30 to ±70) Operating Humidity 5 to 95% RH (Non-condensing) 11.0 SRPM Specifications ................26 Altitude 2000m (max.) 12.0 Electrical....................27 *Operating temperature limits of the electronics only. 13.0 RETURNING PRODUCTS FOR REPAIR ..........28 Physical Description 14.0 Warranty and Limitations of Liability..........28...
  • Page 4 Such actions may permanently damage the pressure sensor. Cleaning your SRPM Do not clean or wash-down the SRPM with industrial cleaners or solvents. The housing may be wiped down with soap and water or isopropyl alcohol; and, the LCD display with isopropyl alcohol only.
  • Page 5: Introduction

    (Model SRPM). Its ease of operation and durable construction will provide years of reliable service. While the SRPM is easy to operate, it is advisable to read this guide carefully before use. It is designed to help you take full advantage of the function and performance of the SRPM.
  • Page 6: Parts List

    2.1 SRPM Parts List Green colored screen Setra SRPM assembly Barbed Coupling, Brass Plated 1/4 inch Tube, Silicone, Inter-Connect 6-32 x 1/2” Mounting Screws for SRPM Base Green Screen Normal Not Included: Supplied by User Single Gang Electrical Box for RPS Plates...
  • Page 7: Installation Instructions

    “Restore Factory Setting” button. Note: The SRPM pressure header plugs into the Setra Model 869 Expert System Calibrator for quick and secure automatic calibra- tion. Exit to return to main menu, then press the “back key” to...
  • Page 8 7.5 SETUP ALARM SCREEN Press to Access Screen a.) Latch Alarm: “Latched Alarm” requires the pressure to return to normal and be acknowledged before alarm can be “Silenced” and “Reset”. b.) Audible Alarm: Enable the Audible Alarm “Yes” or use visual only alarm “No”...
  • Page 9: Mounting And Wiring

    Power leads and wiring should be 14 to 22 AWG braided wire. 18 AWG braided *Note: Use the eraser end of a pencil or back-end of a pen to press (or tap) box on screen to wire is recommended for wiring J3 power connector to SRPM (see J3, Figure 2). increase accuracy of inputs...
  • Page 10: Attaching Pressure Tubing

    RPS to the 4” x 4” electrical box for the 7.3.1 Setup Unit Operation SRPM by pushing the 1/4 inch tube onto one end Press (or tap) button to select an output or engineer- of the barbed, male to male, tube adaptor, then ing unit.
  • Page 11: Model Sran Room Annunciator Installation

    Setup password, output, engineering units, and display averaging 4.1.2 Non-Setra Remote Annunciator The SRPM can drive other annunciators that are powered by a 15V sup- Setup Room Setup high and low pressure limits to ply, 50 mA max., and accept a 15V trigger. If purchased separately, the monitor positive or negative room SRAN can also be driven as shown in Figure 9.
  • Page 12: Audible Alarm

    7.0 Startup and Operation Alarm potentiometer adjusts from 0 to 85 dBA. Using a screwdriver, adjust The SRPM is designed with an easy to use touchscreen interface. In its nor- potentiometer to increase or decrease volume. mal state the “Monitoring Screen” displays the actual room static pressure..
  • Page 13: Electrical Installation

    6.0 Electrical Installation 6.1 Analog Output (J5) SRPM can be configured as current (4 to 20 mA) or voltage (0 to 5 or 0 to 10 VDC). Voltage output pin 1, Current output pin 2, Common pin 3. Note 1.: Electropneumatic Header 1 (see Fig 7, page 10) must be connected to get analog output.
  • Page 14: User's Operating Instructions

    User’s Operating Instructions...