Frigidaire 27” Use And Care Manual
Frigidaire 27” Use And Care Manual

Frigidaire 27” Use And Care Manual

27” (69 cm) wide laundry center
Table of Contents

Advertisement

Available languages

Available languages

27" (69 cm) Wide
LAUNDRY CENTER
Washer - Electric Dryer
Washer - Dryer
Use and Care Guide
Installation Instructions
CENTRO DE LAVANDERÍA
de 27" (69 cm) de ancho
Lavadora - Secadora eléctrica
Manual de Uso y Cuidado
Instrucciones para la instalación
Models/Modelos
P/N 134897500A (0804)
Made in USA

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Frigidaire 27”

  • Page 1 27” (69 cm) Wide LAUNDRY CENTER Washer - Electric Dryer Washer - Dryer Use and Care Guide Installation Instructions CENTRO DE LAVANDERÍA de 27" (69 cm) de ancho Lavadora - Secadora eléctrica Manual de Uso y Cuidado Instrucciones para la instalación Models/Modelos P/N 134897500A (0804) Made in USA...
  • Page 2: Table Of Contents

    Table Of Contents SUBJECT PAGE Pre-Installation Requirements............................3 Electrical Requirements..............................3 Water Supply Requirements ............................3 Drain Requirements...............................3 Exhaust System Requirements ...........................4-5 Gas Supply Requirements ..............................5 Location................................5 Rough-ln Dimensions..............................6 Mobile Home Installation............................7 Unpacking..............................7 Electrical Installation..............................8 Grounding Requirements..............................8 3 & 4-Wire Connections ..............................9 Installation..............................10-11 Replacement Parts..............................11 Español...............................12-20 Laundry Center Safety...
  • Page 3: Pre-Installation Requirements

    PRE-INSTALLATION REQUIREMENTS GAS Laundry Center Tools and Materials Required for Installation: 1. Phillips head screwdriver. CIRCUIT - Individual 15 amp minimum branch circuit fused with 2. Channel-Iock adjustable pliers. a time delay fuse or circuit breaker. 3. Carpenter’s level. POWER SUPPLY -3 wire, 120 volt single phase, 60 Hz, 4.
  • Page 4: Exhaust System Requirements

    EXHAUST SYSTEM REQUIREMENTS Do not allow combustible materials (for Use only 4 inch (10.16 cm) diameter (minimum) rigid or example: clothing,draperies/curtains, paper) to come in contact flexible metal duct and approved vent hood which has a with the exhaust system. The dryer MUST NOT be exhausted swing-out damper(s) that opens when the dryer is in into a chimney, a wall, a ceiling, or any concealed space of a operation.
  • Page 5: Gas Supply Requirements

    The laundry center may be exhausted four (4) ways with rear To exhaust up, add an 11 inch (27.94 cm) length of standard 4 flush installation: inch (10.16 cm) diameter duct and a 90° elbow. The unit will 1. Straight back be positioned about 4½...
  • Page 7: Mobile Home Installation

    MOBILE HOME INSTALLATION 1.Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. 2.If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home...
  • Page 8: Electrical Installation

    GROUNDING REQUIREMENTS ELECTRICAL INSTALLATION ALL ELECTRIC Laundry Centers Non-Canadian ELECTRIC Laundry Center DANGER WARNING Improper connection of the equipment The following are specific requirements for grounding conductor can result in a risk of electrical shock. proper and safe electrical installation of your laundry center. Check with a licensed electrician if you are in doubt as to whether Failure to follow these instructions can create electrical shock the appliance is properly grounded.
  • Page 9: 4-Wire Connections

    ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM FOR A 4-WIRE SYSTEM NON-CANADIAN ELECTRIC Laundry Center NON-CANADIAN ELECTRIC Laundry Center 1. Remove the screw securing the terminal block access cover to 1. Remove the screw securing the the rear panel and remove cover. terminal block access cover to the rear panel and remove cover.
  • Page 10: Installation

    INSTALLATION 1. Run some water from the hot and cold faucets to flush the c. Open the shutoff valve in the gas supply line. water lines and remove particles that might clog up the water valve screens. d. Test all connections by brushing on a soapy water solution. NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME.
  • Page 11: Replacement Parts

    REPLACEMENT PARTS 10. Connect the exhaust duct to outside duct work. Use duct If replacement parts are needed for your laundry center, contact tape to seal all joints. the source where you purchased your laundry center. WARNING 11. Plug the power cord into a grounded outlet. Destroy the carton, plastic bags, and metal band after the laundry center is unpacked.
  • Page 12: Español

    Indice MATERIA PAGINA Requerimientos de instalación preliminares........................13 Requerimientos eléctricos...............................13 Requerimientos del suministro de agua..........................13 Requerimientos de desagüe.............................14 Requerimientos del sistema de escape........................14-15 Requerimientos del suministro de gas..........................15 Ubicación..................................15 Dimensiones para la instalación............................16 Instalación en casas móviles............................17 Desembalaje.................................17 Instalación eléctrica..............................18 Requerimientos para la puesta a tierra..........................18 Conexiónes eléctricas - trifilares y tetrafilares........................18-19 Instalación................................19-20 Repuestos.................................20...
  • Page 13: Requerimientos De Instalación Preliminares

    REQUERIMIENTOS DE INSTALACIÓN Centro de lavandería a GAS PRELIMINARES CIRCUITO - Circuito individual derivado de 15 amp mínimo, con Herramientas y materiales necesarios para la instalación: fusibles de retardo máximo o disyuntor. 1. Destornillador Phillips 2. Alicates universales ALIMENTACIÓN ELÉCTRICA - Corriente alterna, monofásica, 3.
  • Page 14: Requerimientos Del Sistema De Escape

    REQUERIMIENTOS DEL SISTEMA DE ESCAPE No permita que los materiales combustibles (por ejemplo: la Utilice solamente ductos metálicos, rígidos o flexibles de 4" ropa, cortinas/cortinajes, papel) tengan contacto con los ductos. (10,2 cm) de diámetro (mínimo) y una caperuza de salida de uso El escape de la secadora NO DEBE dirigirse hacia el interior de aprobado, con registros que giren hacia afuera que se abren cuando una chimenea, hacia una pared, hacia el cielo raso o hacia cualquier...
  • Page 15: Requerimientos Del Suministro De Gas

    Se puede colocar el ducto de escape de cuatro (4) maneras puede ser instalada directamente a través de la pared exterior. distíntas cuando el artefacto està instalado con el fondo paralelo Para colocar el ducto de escape hacia arriba, añada un ducto 11 con la pared.
  • Page 17: Instalación En Casas Móviles

    INSTALACIÓN EN CASAS MÓVILES Esta secadora ha sido diseñada PARA 1. El tubo de escape de la secadora DEBE ser instalado hacia el USO DOMESTICO solamente, de acuerdo con la norma ANSI Z exterior (El escape debe colocarse en la parte exterior y no 21.5.1.
  • Page 18: Instalación Eléctrica

    INSTALACIÓN ELÉCTRICA Para una lavanderia conectada permanentemente: 1. La lavanderia DEBE ser conectada a un sistema de cableado TODAS los centro lavandoria ELÉCTRICAS metálico permanente, puesto a tierra; o se debe instalar un conductor de puesta a tierra de equipo junto con los conductores del circuito y conectarse al borne de puesta a tierra Los siguientes requerimientos son del equipo o al cable del artefacto.
  • Page 19: Instalación

    4. Conecte el conductor neutro del cordón eléctrico (cable central) 3. Desconecte el cable de puesta a tierra neutral del tornillo al borne central plateado del tablero de bornes. Apriete verde de puesta a tierra situado en la parte superior del tablero firmemente el tornillo.
  • Page 20: Repuestos

    10. Conecte el ducto de escapeal sistema de escape exterior. Utilice 7 . CONEXIÓN DEL GAS (Secadoras a gas solamente) cinta para obturar todas as uniones. a. Saque la tapa de embarque de la tubería de gas de la secadora situada en la parte trasera. 11.Conecte el cordón eléctrico a un tomacorriente puesto a tierra.

Table of Contents