Electronic Module Display; How To Read The Electronic Module Display - eSpring Water Purifier Owner's Manual

Espring water purifier
Hide thumbs Also See for Water Purifier:
Table of Contents

Advertisement

How to read the electronic module display

Status
Water Drops
Normal display w/water fl ow
Top Shroud removed
(Reseat for display)
Filter Cartridge not installed
Lamp not lit (lamp problem)
Early warning
End of life
Water Purifi er needs servicing
Water Purifi er
Flashing/Blue
malfunction

Electronic module display

The electronic display on the eSpring
the water usage litres and time since the last fi lter change. When
properly plugged into an electrical outlet, the Purifi er will display its
status via the Electronic Module LED display.
CUP Icon
On/Blue
Blue
On/Blue
Off
On/Blue
Off
On/Blue
Red
On/Blue
Blue
On/Blue
Red
On/Blue
Off
Flashing/Blue
Water Purifi er keeps track of
FILTER Icon
Life indicator
On/Blue
On/Blue
On/Blue
On/Blue
Off
Off
On/Blue
On/Blue
On/Blue
Last segment
fl ashing
Flashing/Blue
Off
Off
Off
Flashing/Blue
Flashing/Blue
BeepER
Comments/Actions
No
Normal
Repeated
Treated water fl ow -
Cup icon On/Red -
Do not operate, replace Top Shroud
Repeated
Install Cartridge light On/Red
Cup icon On/Red
Repeated
Phone icon On/Red; Need
replacement Filter Cartridge
Once at fl ow start
10% of life remaining
Every 2 seconds
Replace Cartridge
light On/Red
Repeated
Cup icon On/Red
Phone icon On/Red
Need new Electronic Module
Constant tone
Phone icon On/Red
All other segments fl ashing
Unplug immediately
9