JVC 0110SKH-MW-MT Instructions Manual page 11

Multi format lcd monitor
Table of Contents

Advertisement

Computer signals (preset)
DVI-D (HDCP) terminals
Resolution
No.
Signal name
Horizontal
1
VGA60
640
2
WVGA60
852
3
SVGA60
800
4
XGA60
1024
5
WXGA (1280)
1280
6
WXGA+60
1440
7
SXGA60
1280
8
WSXGA+60
1680
9
UXGA60*
5
1600
10
WUXGA60*
5
1920
11
720/60p
1280
12
1080/60p*
5
1920
13
720/50p
1280
14
1080/50p*
5
1920
*
5
For DT-V20L3G: When No. 9, 10, 12 or 14 signals come in, thin lines will become obscured because their signal
resolution is higher than the screen resolution.
• Non-preset signals may not be displayed normally even if their frequency is within the acceptable range (☞
"Horizontal/vertical frequency (computer signal)" on page 26).
• When a preset signal comes in, the signal format is shown on the status display. For other signals, the
resolution is shown.
Frequency
Horizontal
Vertical
Vertical (Hz)
(kHz)
480
31.5
59.9
480
31.5
59.9
600
37.9
60.3
768
48.4
60.0
768
47.8
60.0
900
55.9
60.0
1024
64.0
60.0
1050
65.2
60.0
1200
75.0
60.0
1200
74.0
60.0
720
45.0
60.0
1080
67.5
60.0
720
37.5
50.0
1080
56.25
50.0
Specification of the DVI-D (HDCP) terminal
Connect it to the DVI-D output terminal on a personal computer.
Pin
Scan system
No.
1
T.M.D.S Data 2–
Non-interlace
2
T.M.D.S Data 2+
Non-interlace
3
T.M.D.S Data 2 shield
Non-interlace
4
NC
Non-interlace
5
NC
Non-interlace
6
DDC Clock
Non-interlace
7
DDC Data
Non-interlace
8
NC
Non-interlace
Non-interlace
NOTE
Non-interlace
Non-interlace
Status indication of DUAL LINK/3G SDI signal information
Non-interlace
When DUAL LINK and 3G SDI signals come in, the status of DUAL LINK is displayed. When "SDI DUAL
Non-interlace
LINK" (☞ page 12) in MAIN MENU is set to "OFF" and a 3G SDI signal comes in, the 3G SDI signal
Non-interlace
information is displayed.
Status indication of DUAL LINK
When "SDI DUAL LINK" (☞ page 12) in MAIN MENU is set to "ON" and an SDI signal is selected, "DUAL
LINK" is displayed.
Status indication of 3G SDI signal information
Following signal information can be displayed when a 3G SDI signal comes in.
3G A-1:
Level A mapping structure 1
3G A-2:
Level A mapping structure 2
3G A-3:
Level A mapping structure 3
3G A-4:
Level A mapping structure 4
3G B-DS1:
Level B data stream 1
3G B-DS2:
Level B data stream 2
3G B-DUAL: Level B DUAL LINK
Pin
Input signal
Input signal
No.
9
T.M.D.S Data 1–
10
T.M.D.S Data 1+
11
T.M.D.S Data 1 shield
12
NC
13
NC
14
+5 V Power
15
GND
16
Hot Plug Detect
Pin
Input signal
No.
17
T.M.D.S Data 0–
18
T.M.D.S Data 0+
19
T.M.D.S Data 0 shield
20
NC
21
NC
22
T.M.D.S Clock shield
23
T.M.D.S Clock+
24
T.M.D.S Clock–
11
ENGLISH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dt-v20l3gDt-v24g1

Table of Contents