Use Gatekeeper; Auto Discovery; Ip Address; Heartbeat Interval (Default Timer Is 10 Seconds - NEC Electra Elite IPK II Installation And Maintenance Manual

H.323 trunk
Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

H.323 Trunk
___________________________________________________________________________________
H.323 Gatekeeper Settings

Use Gatekeeper:

Check this field to use an H.323 gatekeeper.

Auto Discovery:

By checking this field, the IAD(8)-U() ETU determines the IP address of the H.323
gatekeeper automatically.


IP Address:

Use this field to specify the IP address for the gatekeeper manually.

HeartBeat Interval (Default Timer is 10 seconds):

This setting tells the IAD(8)-U( ) to broadcast a "heartbeat," or reminder broadcast
updating its status to other machines on the network. This ensures the status of the
IAD(8)-U() ETU is known.
___________________________________________________________________________________
Hardware, Installation and Maintenance Manual
Automatic discovery is accomplished if the host and gatekeeper are in the same
network.
Document Revision 1