Nuova Simonelli Appia User Handbook Manual

Nuova Simonelli Appia User Handbook Manual

Espresso coffee machine
Hide thumbs Also See for Appia:

Advertisement

LIBRETTO ISTRUZIONI
USER HANDBOOK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Appia and is the answer not in the manual?

Questions and answers

Summary of Contents for Nuova Simonelli Appia

  • Page 1 LIBRETTO ISTRUZIONI USER HANDBOOK...
  • Page 2 EN 60335-2-75:2004 + A1:2005 + A11:2006 in combination with EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 EN 50366:2003 + A1:2006...
  • Page 3 You will see how practical, convenient and efficient working with If this is the first time you have bought a Nuova Simonelli coffee machine, welcome to high quality coffee-making; if you are already a customer of ours, we feel flattered by the trust you have shown us.
  • Page 4: Technical Characteristics

    TECHNICAL CHARACTERISTICS 2 Groups 3 Groups 133 lb 163 lb NET WEIGHT 60 kg 74 kg GROS WEIGHT 143 lb 176 lb 65 kg 80 kg 3000 W 5000 W POWER 3000 W 5000 W 30 ⁷⁄₈ ” 39 ⁷⁄₈ ” DIMENSIONS 785 mm 1010 mm...
  • Page 5: Table Of Contents

    HANDLING ....... . .32 APPIA V MACHINE FUNCTION MESSAGES ..... . .43...
  • Page 7: Description

    DESCRIPTION V - Esse Fig. 1 1 Select buttons 9 Pressure gauge 2 Delivery buttons 10 Adjustable foot 3 Steam knob 11 Hot water nozzle 4 Steam nozzle 12 Rating plate 5 Filter holder 13 Main switch 6 Single delivery spout 14 Cup warmer (optional) 7 Double delivery spout 8 Optical level...
  • Page 8: Accessories List

    ACCESSORIES LIST Fig. 2 CODE DESCRIPTION QUANTITY Filling tube ³⁄₈ ” Waste pipe Ø 25 mm - L. 150 cm Filter-holder Double filter Single filter Blind filter Spring Double delivery spout Single delivery spout Coffee presser...
  • Page 9: Safety Prescription

    SAFETY PRESCRIPTION This book is an integral and essential For appliances powered at 220 -230 Before connecting the appliance part of the product and must be given V, the maximum impedance from the make sure the rating plate data cor- to the user.
  • Page 10 This appliance is not suitable for use Before performing any maintenance WARNING by children or persons with reduced operation, the authorised service physical, sensory or mental capabili- engineer must switch off the machine The power cord may only be replaced by a ties, or by persons with a lack of switch and unplug the machine or Qualified Electrician, using an Original...
  • Page 11 Do not obstruct the extraction and/or CAUTION CAUTION dissipator grids, especially of the cup RISK OF INTOXICATION warmer. INFORMATION Use the steam nozzle with care and USERS never place hands below the jet of The user must not replace the Under the senses of art.
  • Page 12: Transport And Handling

    TRANSPORT AND HANDLING MACHINE HANDLING IDENTIFICATION CAUTION Always quote the machine serial number in all communications to the manufacturer, Nuova Simonelli. RISK OF IMPACT OR CRASHING During all handling operations, the operator must ensure that there are no persons, objects or property in the handling area. The pallet must be slowly raised to a height of 30 cm (11,8 in) and moved to the loading area.
  • Page 13: Installation And Preliminary Operations

    3mm. WARNING NOTE: In case of use where service is conti- Nuova Simonelli is not liable for any dama- nuous, make the above changes at ge to people or objects due to not observing Recommended mains pressure for the least once a week.
  • Page 14: Adjustments To Be Made By A

    “A” ONLY be performed by a Specialist off; Technical Engineer. Nuova Simonelli cannot be held liable for any damage to persons or property arising from failure to observe the safety instruc- Fig. 14 tions supplied in this manual.
  • Page 15: Hot Water Economiser Adjustment (Optional V/Esse Model)

    • The set pump pressure is shown on the PUSH-BUTTON PANEL lower part of the gauge. REPLACEMENT For correct functioning of the machine, perso- nalising each button panel card at time of replacement is necessary; proceed as follows on the selectors placed on the card (on the key side).
  • Page 16: Use

    When servicing the electronic machine klet. Set the desired function on the available keys card, switch off the machine using the placed above the filter-holders (see chapter external main switch and unplug the power APPIA V “DESCRIPTION”). cord. 6.1.1 SWITCHING THE MACHINE 6.1.2 SWITCHING THE MACHINE •...
  • Page 17: Making Coffe

    NOTE: when in pause, leave the filter-holder full of milk (preferably cone-shaped). Turn on MAKING COFFEE inserted in the unit so that it will keep the steam. Before the milk starts to boil, pull the warm. To guarantee the utmost thermic nozzle slightly up and lightly move it vertically stability during use, the delivery units across the surface of the milk.
  • Page 18: Programming Appia

    PROGRAMMING Appia V • Delivery will cease and the selected dose PROGRAMMING key will switch off (the other keys will conti- • The delivery buttons for the first and second DOSES nue to flash). group will respectively show the automatic...
  • Page 19: Programming Standard Doses

    2. Enabling the software block to enter the PROGRAMMING STAN- PROGRAMMING OPE- dose programming function. DARD DOSES RATING PARAMETERS • It is possible to enter pre-set values for the Use the long coffee key to enable a 4 group doses and water (steam). CAUTION software block to programme doses (key lit) or to de-activate the block (key off).
  • Page 20: Automatic Group Cleaning Cycle

    If the cup warmer is not enabled, the AUTOMATIC GROUP Hold down the keys for 2 CLEANING CYCLE key will only switch on during the Flash-test, seconds more to force exit from the cleaning after which this key will have no effect when mode, resetting all information about rinse To enter the automatic cleaning mode, switch pressed.
  • Page 21: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CLEANING THE UNIT During maintenance/repairs, the parts used WARNING must be able to guarantee compliance with the WITH THE AID OF THE It is not possible to clean the machine using BLIND FILTER safety and hygiene requirements envisaged for water jets or standing it in water.
  • Page 22: Resin And Softener Regeneration

    3) Reposition lever D towards the left (Fig. 32). RESIN AND SOFTENER REGENERATION To avoid scaling deposits in the boiler and in the heating exchangers, the softener must always be kept efficient. Therefore, the ionic resins must be regularly regenerated. Fig.
  • Page 23: Appia V Machine Function Messages

    Appia V MACHINE FUNCTION MESSAGES DISPLAY AND KEY EFFECT INDICATIONS CAUSE SOLUTION NOTES Drawing of continued key flas If the delivery isn’t Interrupt delivery. If the doser doesn’t send out its set commands manually halted, the within the first three...
  • Page 24 NOTES: ....................................
  • Page 26: Electric System Appia Esse2/3 Gr

    IMPIANTO ELETTRICO /ELECTRIC SYSTEM Appia ESSE 2/3 GR. Fig. 33...
  • Page 27 IMPIANTO ELETTRICO /ELECTRIC SYSTEM Appia ESSE 2/3 GR. LEGENDA EV H EV H Elettrovalvola vapore/acqua Steam / hot water solenoi- calda valve EV S EV S Elettrovalvola scaldatazze Cup warmer solenoid valve EV1-2-3 EV1-2-3 Elettrovalvola erogazione Group delivery solenoid gruppo...
  • Page 28: Electric System Appiav 2 Gr

    IMPIANTO ELETTRICO /ELECTRIC SYSTEM Appia V 2 GR. Fig. 34...
  • Page 29 IMPIANTO ELETTRICO /ELECTRIC SYSTEM Appia V 2 GR. LEGENDA Cup warmer solenoid valve Elettrovalvola scaldatazze EVHW EVHW Hot water mixer solenoid Elettrovalcola miscelatore valve acqua calda EV L EV L Level solenoid valve Elettrovalvola livello EV1-2-3 EV1-2-3 Elettrovalvola erogazione Group delivery solenoid...
  • Page 30: Electric System Appiav 3 Gr

    IMPIANTO ELETTRICO /ELECTRIC SYSTEM Appia V 3 GR. Fig. 35...
  • Page 31 IMPIANTO ELETTRICO /ELECTRIC SYSTEM Appia V 3 GR. LEGENDA Cup warmer solenoid valve Elettrovalvola scaldatazze EVHW EVHW Hot water mixer solenoid Elettrovalcola miscelatore valve acqua calda EV L EV L Level solenoid valve Elettrovalvola livello EV1-2-3 EV1-2-3 Elettrovalvola erogazione Group delivery solenoid...
  • Page 32: Plumbing System

    IMPIANTO IDRAULICO /PLUMBING SYSTEM Fig. 36...
  • Page 33 IMPIANTO IDRAULICO /PLUMBING SYSTEM LEGENDA 1 Rubinetto ingresso acqua 1 Water entrance faucet 2 Pompa 2 Pump 3 Valvola di ritegno 3 Retaining valve 4 Valvola di espansione 4 Expansion valve 5 Elettrovalvola di livello 5 Refill electrovalve 6 Dosatore volumetrico 6 Flowmeter 7 Scambiatore di calore 7 Heat exchanger...
  • Page 34 LLC 6940Salashan PKWY BLDG A 98248 Macerata Italy Ferdale, WA Tel. +39.0733.9501 Tel. +1.360.3662226 Fax +39.0733-950242 Fax +1.3603664015 www.nuovasimonelli.it videoconf.+1.360.3188595 E-mail: n.simonelli@nuovasimonelli.it www.nuovasimonelli.it info@nuovasimonelli.com La Nuova Simonelli si riserva di apportare tutte le modifiche ritenute necessarie. Graphics and printing by: X TYPE ENGINEERING S.r.l.

Table of Contents

Save PDF