• If foam or liquid comes out with the vacuum exhaust, switch the power off immediately. Verify that there are not foreign objects from preventing the fl oat ball from moving freely. Contact Clarke if the problem persists. • Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure, or chemical content.
INTRODUCTION This manual will help you to get the most from your Clarke All Purpose Cleaner. Read it thoroughly before operating the machine. This product is intended for commercial use only. PARTS AND SERVICE Repairs, when required, should be performed by Clarke service personnel using original replacement parts and accessories.
KNOW YOUR MACHINE DESCRIPTIONS Operator Handle (1): Operator holds onto this handle to move the machine from one location to another. Solution Tank Lid (2): This lid screws off so the tank can be fi lled. The solution fi ll hose is tethered to the lid, and hangs inside the arm of the Operator Handle.
KNOW YOUR SWITCH PLATE Vacuum Switch (1): turns on the vacuum motor. Chemical Valve (2): switches between the two chemical containers. When the selector is pointed straight down, the valve is off and neither chemical is selected. When the selector is pointed directly towards one or the other symbols, that chemical is selected.
OPERATION 1) Insert the appropriate metering tips into the chemical feed lines (see illustration, page 5). 2) Fill the holding tank with warm water (not exceeding 120 °F). Do not add any chemical to the tank. 3) Prepare the area for cleaning by emptying waste receptacles, clearing debris, removing paper products, blowing out vents, and sweeping fl...
Pressure regulator, for 400 psi pump 56380913 Chemical Injector and Metering Tip kit 56380940 Gun sleeve and gaskets 56380941 Seals and rivets, for switch plate MISCELLANEOUS PARTS 56380921 Label kit, “TFC 400” & warning *56380928 Pallet assembly with components, complete REV C 11-2009...
Clean solution fi lter Check vacuum motor airways Check pump for leaks Check vacuum motor brushes * * Have Clarke check the carbon brushes once a year or after about 500 hours of operation. TECHNICAL SPECIFICATIONS Vacuum motor: 2-stage, 8 amp Water lift: 97”...
Page 12
(b) Return the product to the nearest Clarke repair location. Transportation charges to and from the repair location must be prepaid by the purchaser. (c) Clarke will repair the product or replace any defective parts without charge within a reasonable time after the receipt of the product.