Page 1
AFTER-SALES SERVICE Hot & Cold SERVICE MANUAL “COLIBRÌ” BASIC TECHNICAL MANUAL THE CONTENTS OF THIS DOCUMENT ARE INTENDED FOR NECTA’S AFTER SALES PERSONNEL...
In the espresso version only the right safety device is present In the Instant version both left and right safety devices are present. View of Colibrì with the door open NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 2 /25...
1) Water inlet solenoid valve 2) Air-break 3) Volumetric counter 4) Pump 5) Pump by-pass (complete with check valve) 6) Pressure boiler (complete with solenoid valve) 7) Brewing unit NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 3 /25...
Page 4
2-way valves, while the espresso boiler solenoid assembly is composed of two 2-way valves and one 3-way valve The configuration is via Software. (See procedures in the software manual) In both versions the dose of liquids is calculated by means of the volumetric counter NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002...
Electrical and board connections: Back view without protective casing Push-button wiring connector CPU and Power supply actuation board cable connector Actuation relay Transformer fuses 10 A line fuses NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 5 /25...
Page 6
Push-button board Cup sensor switch Water sensor (level) switch (air-break) Liquid waste overflow switch (previsions for a model with a support cabinet) CMSB Cup release motor cam NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 6 /25...
Page 7
TRIAC - boiler heating element actuation Boiler heating element connector Connector for 230 V AC users Relay for actuations (K1 - K15, see separate list page 8) NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 7 /25...
Page 8
Stirrer dispensing motor K 15 Stirrer dispensing motor The control board can be configured for the different machine versions only via software settings. See Software and Programming chapter NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 8 /25...
Page 9
These cards are available as “optional” features, assuming that for the specific range of the Colibrì vending machine normally a parallel communication system with front validators is used. Wiring connection diagram for payment systems with the different protocols NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002...
Page 10
LCD contrast adjustment trimmer Programming mode button Washing cycle button RS 232 port (Optional and only active if a serial card is installed) Programmer device connector Push-button board connector NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 10 /25...
(e.g. 60 sec.) the vending machine locks due to a water failure. Air-break level control microswitch Air-break Overflow tube Water inlet solenoid tube Mains water inlet solenoid valve Back view without protective casing NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 11 /25...
Page 12
3.1 - BOILERS The Colibri model is fitted with only one boiler of the pressure type, used in both the Espresso (mixed solenoid valve assembly with two 2-way valves and one 3-way valve) and Instant versions; however this latter version is fitted with three 2-way valves.
C self-resetting klixon. The by-pass is factory pre-set at 12 bars. The pump is activated by relay K 14. KLIXON By- pass Overheating protection Detail boiler module - pump end NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 13 /25...
After a long pause the first espresso coffee could be of a slightly lower temperature than the optimum one. The Kit (ref. 7) ensures optimum temperature in the brewing chamber, without altering the taste as it happens in currently marketed systems (burnt taste). NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002...
Operation: The release ratiomotor is triggered by relay K 24 and the sugar release spout is rotated at the same time as the stirrer release system is activated. Description Stirrer dispensing unit fastener Lock Stirrer length adjustment slots Door switch Stirrer positioning weight NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 15 /25...
9 - MIXER UNIT Apart from their application, the mixer is the usual excellent and reliable ones used in the entire Necta production. A mixer must have two main features: 1) Ease of disassembly and limited number of components to be able to meet the HACCP directive.
Therefore, in the event of changing the default doses set at the factory, some measurements must be made using graduated measuring containers to check the accuracy of the doses. NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002...
(flow-meter) used to measure also the programmed in the SW. instant product doses). If such dose is not reached within 60 sec it means that there NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 19 /25...
Page 20
HW control of such situation, “Water leak” the SW stops the mains inlet carefully check the hydraulic system to find any leaks. solenoid valve to avoid any flooding. NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 20 /25...
When the display indicates an error message immediately check the trouble-shooting sheet. Use only recommended cleaning products approved for foodstuff, preferably liquid; avoid the use of powder and abrasive products. NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002...
FIG. 3 Note: After restarting the machine FIG. 4 remember to reset the solid waste container by removing it and reinserting it again. FIG. 6 FIG. 7 FIG. 5 NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 23 /25...
Carry out an automatic mixer wash cycle, according to the preset procedures. Enter the operations carried out on the log. FIG.5 FIG. 8 FIG. 7 FIG. 6 NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 24 /25...
Enter the operations carried out in the HACCP hygiene program log FIG. 7 FIG. 5 FIG. 6 NECTA SPA TECHNICAL MANUAL “COLIBRÌ” Service Manual: Colibrì Edition 02-2002 25 /25...