VCL - RS485
IntelliBus™
Camera Address Settings
Document 800-01023 Rev A
02/08
For VCL - RS485 protocol, the commonly used setting is 9600 baud, no parity.
SW5 - 11000001 (positions 1–8).
In above SW5–8 is ON to force reading from DIP switches. See
Override, page 26, for more information on setting SW5–8.
SW6 - 00100000 (positions 1–8) sets the ACUIX to 9600 baud with no parity.
SW5 - 00000001 (positions 1–8).
In above SW5–8 is ON to force reading from DIP switches. See
Override, page 26, for more information on setting SW5–8.
SW6 - 01100000 (positions 1–8) sets the ACUIX to 38400 baud with no parity.
Address selection is via rotary switches SW1, SW2, SW3, and SW4.
Table 2-4
ACUIX Camera Addresses
Address
SW1
SW2
SW3
SW4
Caution
The ACUIX can be addressed from 0000 to 9999. The addressing
scheme may be restricted due to the limitations of the controller
being used to control the ACUIX. For example, the
HEGS5000/HEGS5001 controllers can control camera addresses 1
to 256. The HJZTP can control camera addresses 1 to 128.
ACUIX High Speed Dome User Manual
Value
Units digit
Tens digit
Hundreds digit
Thousands digit
DIP Switch Address
DIP Switch Address
25