Summary of Contents for OHAUS EC Series

  • Page 1 EC Series Instruction Manual 1 EC-front cover.pmd 8/9/2005, 1:41 PM...
  • Page 2 Ohaus Corporation,19A Chapin Road, PO Box 2033, Pine Brook, NJ 07058 USA Declaration of Conformity We, Ohaus Corporation, declare under our sole responsibility, that the scale models listed below are in conformity with the directives and standards mentioned. Declaración de Conformidad Nosotros, Ohaus Corporation, declaramos bajo responsabilidad exclusiva que los modelos de bascules indicados a continuación están conformes con las...
  • Page 3 Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 4 2 EC CE PAGES.pmd 8/9/2005, 1:41 PM...
  • Page 5: Table Of Contents

    EC Series EN-1 1 INTRODUCTION ................EN-2 1.1 Product Description .............. EN-2 1.2 General Features ..............EN-2 1.3 Safety Precautions ..............EN-2 2 INSTALLATION ................EN-3 2.1 Unpacking ................EN-3 2.2 Installing Components ............EN-3 2.3 Selecting the Location ............EN-3 2.4 Leveling the Scale ..............
  • Page 6: Introduction

    1.1 Product Description The EC Series is an economical compact counting scale designed for fast, accurate operation ideally suited for annual inventories, parts rooms, rentals and other counting applications. Combining an internal accuracy of 1:600,000, Average Piece Weight (APW) of 0.01g/0.00002lb to 0.1g/0.0002lb (depending on model) and an internal...
  • Page 7: Installation

    EC Series EN-3 2 INSTALLATION 2.1 Unpacking Unpack and verify that the following components have been included: EC Scale Weighing Platform (plastic base with stainless steel pan) Instruction Manual AC Adapter Save the packaging material. This packaging ensures the best possible protection for the storage or transport of the product.
  • Page 8: Connecting Power

    Dispose of the lead acid battery according to local laws and regulations CAUTION BATTERY IS TO BE REPLACED ONLY BY AN AUTHORIZED OHAUS SERVICE DEALER. RISK OF EXPLOSION CAN OCCUR IF REPLACED WITH THE WRONG TYPE OR CONNECTED IMPROPERLY 2.6 Initial Calibration...
  • Page 9: Overview Of Controls And Functions

    EC Series EN-5 3 OVERVIEW OF CONTROLS AND FUNCTIONS 3.1 Display Symbols • Weight Window - displays weight of object on “WEIGHT” weighing pan, or accumulated weight value • Center of Zero Indication • Tare or Pre-set Tare (PT) Indication •...
  • Page 10: Controls And Functions

    EN-6 EC Series 3.2 Controls and Functions • Inputs the indicated sample size and weight to calculate APW • Inputs the weight of the object on the weighing pan as a Tare value • Long press – enters user setup mode •...
  • Page 11: Operations

    EC Series EN-7 4 OPERATIONS 4.1 Switching the Unit On and Off The power switch is located underneath the right-hand side of the scale. Push the switch to the “I” position to turn the scale on, and to the “O” position to turn the scale off.
  • Page 12: Zero Operation

    EN-8 EC Series 4.4 Zero Operation Center of Zero is indicated by the annunciator. Press ZERO to zero the weight dis- Weight Count Piece Weight g/pc play. ------. ------. CEntr “CEntr” will be displayed momentarily before the display is zeroed.
  • Page 13: Storing Piece Weight Into Memory

    EC Series EN-9 4.7 Storing Piece Weight into Memory There are 10 memory locations (0 to 9 numeric keys) available to store APW values. After determining the piece weight Weight Count Piece Weight g/pc (refer to Sec. 4.5 or 4.6 ), long-press 0.0.
  • Page 14: Scale Settings

    EN-10 EC Series 5 SCALE SETTINGS Long-press TARE to enter into the user-selectable scale settings (Setup mode). In Setup mode: o Press Sample to step through available settings o Press Tare to accept the displayed setting and proceed to the next Setup parameter Press C at any time to exit from the Setup mode.
  • Page 15: Zero Return Range

    EC Series EN-11 5.5 Zero Return Range Sets the level in which the zero point Weight Count Piece Weight g/pc is stable; the higher the setting, the ------. t.rAtE more stable. The following settings are available: Default Setting Zero Return Range...
  • Page 16: Calibration

    NOTE: Press Zero at any time to abort during the calibration process. 7. TROUBLESHOOTING The following table lists common problems, possible causes and remedies. If the problem persists, contact Ohaus or your authorized Ohaus dealer. Symptom Possible Causes Remedy Scale will not turn on.
  • Page 17: Technical Data

    EC Series EN-13 8. TECHNICAL DATA Model EC15 EC30 Capacity x Readability 3000 g x 0.1 g 6000 g x 0.2 g 15000 g x 0.5 g 30000 g x 1 g 6 lb x 0.0002 lb 15 lb x 0.0005 lb 30 lb x 0.001 lb 60 lb x 0.002 lb...
  • Page 18: Limited Warranty

    Ohaus. In lieu of a properly returned warranty registration card, the warranty period shall begin on the date of shipment to the authorized dealer.