Table D-3 Error Codes - Motorola DCP501 Installation Manual

Home theater system
Hide thumbs Also See for DCP501:
Table of Contents

Advertisement

D-6
Diagnostics
Table D-3 lists the error codes:
Table D-3
Error codes
Initialization status errors
Error Code
OSD
E 00*
NO ERROR
NOT CONNECTED
E 01*
E 02
PWR CYCLE
DRAM
E 03
DPSRAM
E 04
ROM
E 07
E 08
RAM
E 09
BATTERY
SERIALNO
E 10
UNIT ADDRESS
E 11
POST
E 12
BOOT
E 13
E 14
STARTUP
TSI INVALID
E 15
E 16
FLASH BAD
NUMBER
BAD PLATVAL
E 17
*E 00 and E 01 cannot be displayed while the DCP501 is off. The other errors will display on the LED
display when the DCP501 is off.
DCP501 Installation Manual
Cause
Indicates normal condition after
initialization
DCP501 did not receive a connect
message
Init Error
DRAM error
DP-SRAM error
ROM verification failure
Faulty RAM, ROM, EEPROM, or
POST failure (this is a hardware
failure)
Dead battery or memory has not been
initialized; occurs if battery fails to
keep the RAM alive during
power-down; causes DCP501 to be
disconnected
Invalid serial number
Invalid unit address
POST failed
Sys_boot initialization failure
DCP501 system startup failure
TSI structure is corrupted
Bad flash number specified for Initiate
Flash Platform
Bad platform validation step number
Remedy
Not applicable
Send a connect message
Restore out-of-band signal
Box needs a Power Cycle
to recover
Not used at this time
Not used at this time
Power cycle box; if
repetitive, return for repair
Return DCP501 for repair
Return DCP501 for repair;
requires factory
initialization message
Not used at this time
Return DCP501 for repair;
requires a unit creation
message
Not used at this time
Power cycle box; if
repetitive, return for repair
Power cycle box; if
repetitive, return for repair
Power cycle box; if
repetitive, return for repair
Error logged, ignore
Error logged, ignore

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents