1. General Information “ELDES UAB” will not take any responsibility regar- ding personal, property or revenue loss while using 1.1 Function .......................4 the system.
When using audio feature in case of zone trigger or restore event the user will be able to listen to particular sound record uploaded to the ESIM251 device memory. After the end of the sound record the system activates the microphone for listening on what is happening in the secured premises.
When choosing GSM cellular provider, it is worth inquiring whether the service is used in security application assuring fast and reliable SMS message delivery and phone call connection. ESIM251 and alarm system COM must be connected. Inputs Z1,Z3,Z4,Z5 are connected to alarm system PGM outputs if PGM are implemented as open collector circuit or any other circuit and if it commutates with COM.
AUX output is used. 4. When AC power supply (ground transformator) is used connect according to circuit no. 3. In this case you do not need to connect any other power supplies. 5. The system will start in less than a minute. LED2 indicator should be blinking or be ON indicating connection to GSM. USER MANUAL ELDES ESIM251 V1.0...
Otherwise check for network connection and call ESIM251 system from your mobile and wait until the system drops the call. You should get an SMS message asking to change default password. Otherwise check for network connection and change SMS central number.
2.3 User Numbers The system ESIM251 allows to pre-program up to five different mobile numbers which will have access to and control the system. NR1 is mandatory while others can be skipped. All numbers must be entered starting with international country code, e. g. national code for Lithuania is 370, UK –...
3. Additional System Capabilities 3.1 Renaming alarm, restore text and controller names Manufacturer initially set the following zone and controlled output names: Zone1, Zone2, Zone3, Zone4, Zone5, OUTPUT1 E. g. if during the alarm Z1 zone was triggered, the system sends SMS message with the text: Zone1 Alarm text changes are made by sending the following SMS message: XXXX_Z1:NewAlarmText;Z2:NewAlarmText;Z3:NewAlarmText;Z4:NewAlarmText;Z5:NewAlarmText;...
3.3 Info on Status SMS The system ESIM251 can any time be inquired about signal strength and the status of zones active at the time when SMS message is sent. At the same time system test is performed. If the answer to the request has been received, it means the system finely operates.
Instead of C1 it is also possible writing a real controller name. E.g.. XXXX_PUMP:ON Timer GSM control system ESIM251 has internal timer clock. This feature allows any controlled output to be switched on or off for a spe- cified time period. The following SMS command should be sent: XXXX_C1:ON/OFF:vv.mm.ss ON –...
3.8 Calling all users During the alarm, ESIM251 system starts calling NR1. If the call to NR1 was unsuccessful or the subscriber was out of network coverage the call is forwarded to NR2 etc. If the user rejected the call or answered te call during the alarm the system stops calling.
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ E. g. 1 The user wants to connect ESIM251 system to an existing alarm in a building where enterprise A and and enterprise B work. Both enterprises use the same alarm system that has two zones.The alarm system has 5 programmable outputs (PGM). Task NO1: Configuring the system so that the director of a particular enterprise is informed about security enabling depending on which enter- prise employee enabled the security system. The director of enterprise A (NO1) wants to receive an SMS message only and does not...
Page 15
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ Task NO2: Configuring the system so that the janitor (NO3) is informed about the triggered perimeter sensor of field territory by SMS messa- ge and a call; and when the sensor is reset, the janitor receives SMS message only.
Page 16
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ E. g. 1 The user wants to connect ESIM251 system to an existing alarm in a building where enterprise A and and enterprise B work. Both enterprises use the same alarm system that has two zones.The alarm system has 5 programmable outputs (PGM). Task NO3: Configuring the system so that the intrusion to enterprise A premises is reported to the janitor (NO3) and enterprise A employee (NO4) by SMS messages and calls. Enterprise A employee (NO4) wants to receive a call only in the case if the janitor (NO3) does not answer the call, is out of network coverage or at that time the janitor’s telephone line is engaged. Director A Enterprise A...
Page 17
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ Task NO4: Configuring the system so that the intrusion to enterprise B premises is reported to the janitor (NO3) and enterprise B employee (NO5) by SMS messages and calls, and the director of enterprise B (NO2) receives SMS message only. Enterprise B employee (NO5) must receive the phone call even in the case when the janitor (NR3) answers the call. Director A Enterprise A Enterprise B Director B Alarm system...
Page 18
NO2-NO5 and left enabled for NO1 only. a) First of all security central unit must be programmed in the way so that when security sensors are triggered the signal must be transmitted to security central unit output PGM. b) PGM is connected to ESIM251 input Z1 c) The following two configuration SMS messages must be sent to ESIM251 system: XXXX_SMSALL:ON where SMSALL enables mandatory SMS message delivery for all users. XXXX_SMSEXTRA:Z1:SC345,CC2345 Where SC345 means that alar SMS message sending is disabled for users NO3, NO4 and NO5 after Z1 zone is triggered.
Page 19
Confirmation call feature must be enabled for user NO5 and it is necessary to choose the length parameters for that call. Also, confirmation SMS messages have to be enabled for user NO3. a) First of all ESIM251 system relay output has to be connected to the connectors of gate control unit. b) The following configuration SMS message must be sent to ESIM251 system: XXXX_SMSEXTRA:COC:CE1345,CS5,CT513,SS3,MS10,MS30,MS40,MS50,MS1T0.0.1,MS3T0.0.1,MS4T0.0.1,MS5T0.0.1 where CE1345 means that C1 relay control via call is enabled for users NO1, NO3-NO5.
Page 20
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ E. g. 3. The user wants to connect ESIM251 system to the heating system of the house. Task No1: Configuring the system so that house heating system is turned on and turned off by the user (NO1) via free call. This user should also receive free information abut successful turning on or turning off of the heating system.
Page 21
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ Task No2: Configuring the system so that users (NO1) and (NO2) receive SMS message about a burst water pipe (flood) at home. SMS mes- sages must be delivered to both users. Flood detector User Heating...
Page 22
SMS message, it is necessary to remove users NO2 and NO3 and disable alarm calls for all users. It is also necessary to invert ESIM251 input from NO to NC mode so that alarm is given only when the signal disappears.
Page 23
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ Task No2: Configuring the system so that the operating personnel member (NO2) receives SMS message if the pump was triggered for 10 times. Pump Worker Gas boiler Alarm ESIM151 Worker Worker Automatic system As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS message, it is necessary to remove users NO1 and NO3 and disable alarm calls for all users.
Page 24
The company taking care of automatic systems needs to have information about critical breakdowns of mechanisms and has to quickly react and eliminate the breakdown. There are three members of operating personnel (NO1), (NO2) and (NO3). Task No3: Configuring the system so that operating personnel members (NO1), (NO2) and (NO3) can reboot the “ hanged” automatic control system without going to the object but via a short call to ESIM251 system. Pump Worker Gas boiler...
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ 3.9.1 Additional possibilities of configuring zones (inputs) alarm and restore Initial factory default settings. During the alarm the system calls and sends SMS messages to all pre-programmed users until the first successful SMS delivery or a call rejected by the user.
Page 26
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ ATTENTION! Value fields are separated by commas. Maximum SMS length is 160 characters. Only one zone parameters can be configured by one SMS message. Examples of using SMSEXTRA command. Suppose in all cases initial parameters were not changed and are manufacturer default.
3.9.2.1 Settings of an output controlled by calls When calling on the number of system ESIM251 the call is rejected and no control operations are run. However, when a special mode is enabled C1 output can be controlled by a call. It can be controlled by all users NO1-NO5, several users or only one of them.
3.9.2.2 Settings of the output controlled by SMS messages This chapter describes the ways of informing users when they are trying to enable/disable the relay via SMS messages described in chapter 3.6. Parameters are changed by sending the following SMS message to system ESIM251: XXXX_SMSEXTRA:OCS:Value1,Value2,……,ValueN XXXX – user password. Value structure is CnVal, where Cn is command name (2 letters), and Val-its value (digits without spaces or...
Page 29
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ Value (CnVal) – table of values Val – possible Cn – command Initial factory...
Output ontrol settings by event time This chapter describes a possibility to control C1 output (relay) using timetable (schedule). It can be, for instance, atomatic turning on every day at 18:00 and turning off after 5 hours. The parameters are changed by sending the following SMS message to the system ESIM251: XXXX_SMSEXTRA:OCTE:Value1,Value2,……,ValueN XXXX – user password. Value structure is CnVal, when Cn is command name (2 letters), and Val-its value. Value (CnVal) – table of values Val –...
Page 31
F O R A D VA N C E D U S E R S All these features can be configured using program “ELDES Configuration Tool“ The first digit is a command; the last digit refers to The user receives call time in seconds.
“ELDES Configuration Tool“ Software To confi gure the system quicker and easier as well as use more system capabilities use configuration software “ELDES Configura- tion Tool“ which can be downloaded from our website www.eldes.lt Before connecting USB cable to the computer read “ELDES Configuration Tool“ user guide available in the program chapter HELP.