Advertisement

Item Number
Maximum Output
Continuous Output:
Gasoline
Liquid Petroleum Gas (LPG)
Natural Gas (NG)
Voltage
Phase
Frequency Regulation
Voltage Regulation
Power Factor
Engine
Engine Speed
Fuel Type
Pressure Range (LPG, NG)
Min. Flow Range (LPG, NG)
Fuel Capacity
Oil Capacity
Starting Method
120V Receptacle
120/240V Receptacle
Circuit Breaker
Battery (not included)
Dimensions
Length
Width
Height
Dry Weight
Gross Weight

Specifications

SPECIFICATIONS
7-11" Water Column, 4-6 oz.
2.2 Gal/Hr (LPG), 3.25 CFM (NG)
20 Amp (A) duplex (NEMA 5-20R)
50 Amp (A) straight blade (NEMA 14-50R)
(1) 50 Amp (A) thermal magnetic
(1) 30 Amp (A) thermal magnetic
(1) 30 Amp (A) thermal, push to reset
(2) 30 Amp (A) thermal, push to reset
6
#165939
13500 Watts (W)
10500 Watts (W)
9600 Watts (W)
8400 Watts (W)
120 / 240 Volt (V)
Single phase (4-wire)
56.5 - 63.3 Hertz (Hz)
218 - 258 V
1.0 p.f.
20 HP Honda
3390 - 3798 RPM
Unleaded gasoline/LPG/NG
10.0 Gallons (38.0 L)
See Honda Manual
Electric
30 Amp (A) locking device
(NEMA L5-30R)
30 Amp (A) locking device
(NEMA L14-30R)
12 Volt, 400 CCA minimum,
Group size U1
35.75" (90.8 cm)
24.25" (61.6 cm)
26.25" (66.7 cm)
340 lb. (155 kg)
410 lb. (186 kg)