Fujitsu RC25 Quick Start Manual page 2

43cm/17" tft rack console
Hide thumbs Also See for RC25:

Advertisement

Installing the RC25 Rack Mount Kits to the Rack
(1) Attach one cage nut on each of the right and left front-side rack braces, and attach another
cage nut on the left rear-side rack brace.
(2) Insert the two protrusions on the rear side of the RC25 Rack Mount Kits into the rear-side
rack braces, so that the inserted RC25 Rack Mount Kits are at the same height unit (U).
One RC25 Rack Mount Kit is for the left rear-side rack brace and the other is for the right. Find the
letters LEFT or RIGHT on the side of each RC25 Rack Mount Kit and attach each RC25 Rack
Mount Kit to the suitable side of the rack.
(3) Keep the RC25 Rack Mount Kits horizontal at the same height unit (U) and attach them to
the front-side rack braces.
Check that the Easy mounting-clips and centering screws are inserted firmly into the front-side
rack braces.
(4) Insert the Security locks into the left and right Easy mounting-clips on the front side of the
RC25 Rack Mount Kits.
Rear-side
rack braces
Protrusions
Cage nut
RC25 Rack
Mount Kits
Cage nut
LEFT
Cage nut
Rear-side rack brace
To install in an asymmetrical PRIMERGY rack:
(1) Use two centering screws (M5 Torx T20) to
install the support bracket on the left rear-side
rack brace.
(2) Install the RC25 Rack Mount Kit.
See above for the installation procedure.
Left rear-side rack brace
(asymmetrical PRIMERGY rack)
Centering screws M5 Torx T20
Support bracket
Inserting the Rack Console
(1) Pull out the intermediate members of the slide rails until the members are locked.
(2) Pull out the retainers to the front ends of the rails.
(3) Insert the Rack Console into the slide rails. Push the Rack Console until it locks on the slide
rails.
Installing the Cable Management Part
(1) Secure the rear bracket of the cable management part with the finger screw on the rear
protrusions of the RC25 Rack Mount Kit on the left rear-side rack brace.
Rear bracket
(2) Fix the front bracket to the fitting on the rear of
the Rack Console.
(3) Insert the pin for fixing the cable management
part into the hole.
Firmly push the pin until the ball lock is securely
in place.
If the ring for removing the pin
CAUTION
rests on the Rack Console or
RC25 Rack Mount Kit after the pin has
been inserted, it might not be possible to
store the Rack Console. Therefore, be
sure that the ring rests on the center of the
unit as shown in this figure.
Easy mounting-clip
Cage nut
Security
lock
Front-side
Centering
rack brace
screw
RIGHT
Cage nut
Security
locks
Front-side rack braces
To remove the RC25 Rack Mount Kit:
(1) Insert the unlocking tool between the Easy
mounting-clip and the Security lock as shown in
the figure, and then remove the Security lock.
Front-side rack brace
(2) Insert the unlocking tool into the opening in
the Easy mounting-clip, disengage the lock, and
then remove the RC25 Rack Mount Kit from
the front-side rack brace.
Retainer
Pin for fixing
the cable
management
Ring for removing
part
the pin
Bracket
Connecting Cables
(1) Turn off all devices that are connected to the RC25, except for hot-plug connections.
(2) Connect the PS/2 (or USB) cable and monitor cable to this device.
The Virtual Media Port (USB) is used to connect a Virtual Media KVM switch (sold separately) to this
device. For more information, see the User's Manual for the KVM switch you are using.
(3) Plug the AC power cable connector into the power socket on this device.
(4) Connect the cables to the
monitor port, keyboard port,
and mouse port on the server
or a KVM switch.
(5) Plug the Rack Console's power
AC power
cable into the power outlet.
ACコード
cable
(6) Make sure that all connections
are completed before turning
on the power of the Rack
Console, server, KVM switch,
and other devices.
* Remark: virtual media cable has to be ordered optionally. Connector color is gray, to distinguish from USB
keyboard/touch-pad cable (black connector)
 Connect the following cables to this device as
shown in this figure, so there is no slack.
 AC power cable on bottom
 Monitor cable on top
 If the cables are pulled too tightly after
connecting the monitor cable to this device,
adjust the lengths of the cables.
Select either the PS/2 cable or USB cable as the cable to
CAUTION
connect the keyboard and mouse. If both cables are connected
and any operational problem occurs on the keyboard or mouse,
the server must be rebooted.
Opening and Closing the Monitor
To open the monitor
(1) Grip the monitor handle and open the monitor upward.
To close the monitor
(1) Make sure that nothing is connected to the Virtual Media USB port on the front side of the
device.
(2) Hold the handle and slowly close the monitor downward.
 When you open the monitor upward, if you cannot open it with one
CAUTION
hand or you feel it is too heavy to open with one hand, open it with
both hands.
 When closing the monitor, make sure there is nothing connected to
the front Virtual Media USB port, and be careful to not pinch your
fingers between the monitor and the keyboard.
Storing the Rack Console
(1) Push the fixing springs on the ends of the right and left slide rails, and slide the device back
into the rack slowly.
(2) Tighten the finger screws on the right and left front ends of the device.
Finger screw
Be careful not to pinch your hands or fingers in the slide rails or
CAUTION
Rack Console itself when you stow the Rack Console.
PS/2
PS/2
Monitor
モニタ
USB cable
cable
ケーブル
USB
cable
PS/2
ケーブル
(KB)
PS/2
(KB)
ケーブル
cable
ケーブル
(MS)
(MS)
Power outlet
Monitor port
モニタポート
電源コンセント
Keyboard and mouse ports
キーボード・マウスポート
(either USB or PS/2)
(USB、PS/2どちらか一方を接続)
Handle
Virtual Media Port (USB)
Finger
screws
NC14010-L593-02
Visual Media Port
Virtual Media Port (U
(USB)*