GE 36” Rangetop Installation Instructions Manual page 15

Table of Contents

Advertisement

Installation
Instructions
WARNING:
This conversion must be
performed by a qualified installer or gas supplier in
accordance with the manufacturer's instructions and
all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency
performing this work assumes responsibility for the
conversion.
WARNING:
The rangetop, as shipped from
the factory, is set for use with its intended gas. If you
wish to use your rangetop with the alternate gas, you
must first replace the orifices and convert the pressure
regulator.
WARNING:
The following adjustments
must be made before turning on the burner. Failure to
do so could result in serious injury. Be sure pressure
regulator has been converted as described in Step 2.
TOOLS YOU NEEDED FOR CONVERSION
Crescent Wrench
Safety Glasses
1/2" Deepwell
Small Pliers
Socket Wrench
1
ORIFICE HOLDER
The range orifice holder is
located behind the front
access panel at the bottom
of the range.
The rangetop orifice holder
is located inside the range insulation cover.
Additional orifices may be present. Use only the orifices
specified in the instructions for your range or rangetop.
Convert Natural Gas to LP Gas Operation
Convert LP Gas to Natural Gas Operation
1/4" and 7mm
Nutdrivers
Small Flat-Head Screwdriver
(2 to 2.4 mm or 3/32" tip size,
60 mm long)
Philips
Screwdriver
Griddle
Grill
Orifice
Orifice
Burner Orifices
2 CONVERT THE REGULATOR
Disconnect all electrical power at the main circuit
breaker or fuse box.
A. Remove the rear vent
trim (on ranges only) to
access the regulator.
The Rangetop
regulator is on the left bottom corner.
B. Shut off the gas supply by closing the manual shut-off
valve in the unit or at the wall.
C. Convert the pressure regulator:
• Unscrew the cap with plunger.
• Place your thumb against flat side of the plunger and
press down to snap the plunger out of the cap.
• Carefully look at the
plunger to locate the
NAT or LP position.
• Turn the plunger over
so that the desired
gas is showing near
the bottom.
• Snap the plunger
back into the cap.
• Screw the cap back
onto the regulator.
3 CHANGE BURNER ORIFICES
INSTALLATION TIP: First remove all
orifices and then start replacing them.
This will help to prevent the possibility
that some may not be replaced.
A. Remove the burner grates,
burner caps and burner heads.
B. Loosen the top burner
orifices using a 7 mm nut
driver. Use small pliers to
carefully lift out the orifices.
The main orifice is
located low in the
center of the burner,
while the simmer
orifice is located
higher beside the
center of the burner.
15
Range Regulator
Gasket
Cap
NAT
LP
Plunger
NAT
LP
NAT.
LP Position
Position
Pressure Regulator
Burner Cap
Burner
Head
Spark
Igniter
Burner Base
Main
Orifice
Simmer
Orifice

Advertisement

Table of Contents
loading

Table of Contents