Dimplex Duo300n Installation Instructions Manual

Dimplex Duo300n Installation Instructions Manual

Radiators

Advertisement

Installation Instructions

Duo300n
Duo400n
Duo500n
1.3kW / 0.38kW 9.1kWh
1.95kW / 0.47kW 13.65kWh
2.6kW / 0.54kW 18.2kWh
- 1 -
87452 : 3 : April 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Duo300n and is the answer not in the manual?

Questions and answers

Summary of Contents for Dimplex Duo300n

  • Page 1: Installation Instructions

    Installation Instructions Duo300n 1.3kW / 0.38kW 9.1kWh Duo400n 1.95kW / 0.47kW 13.65kWh Duo500n 2.6kW / 0.54kW 18.2kWh 87452 : 3 : April 2009 - 1 -...
  • Page 2 Circuit Diagram Charge Control Thermostat Over Temperature Cut Out StorageHeater Elements Room Sensing Thermistor Core Sensing Thermistor Charge Controller Module User Interface Module Peak Supply Radiant Element Live Neutral Pilot Wire Manual Fit Connector Live Storage In Live Storage Out Live Radiant In Live Radiant Out Signal In...
  • Page 3 Width Depth Modèle Hauteur Largeur Épaisseur Modelo Altura Comprimento Espessura Modello Altezza Larghezza Profondità Model Wys. Szer. Gleb. Duo300n 712mm 600mm 130mm+10mm Duo400n 712mm 830mm 130mm+10mm Duo500n 712mm 1060mm 130mm+10mm Curtains Rideaux Cortinas Tende Firanki étagère ou consoles Prateleira ou objecto Półka lub część...
  • Page 4 1. Feet 2. Accessories Bag 1. Pieds 2. Sac à accessoires 1. Pés 2. Saco de acessórios 1. Piedini 2. Sacchetto accessori 1. Nogo 2. Worek z akcesoriami 10mm - 4 -...
  • Page 5 30mm 1. Brick 2. 8mm Drill 3. 3” No. 10 Screws (supplied) 5. Plaster 6. Low density block 7. Special fi xing 4. Length +15mm 5. Enduit 6. Bloc de faible densité 7. Fixation spéciale 1. Brique 2. Foret 8mm 3. Vis N° 10 3” (fournies) 5.
  • Page 6 - 6 -...
  • Page 7 - 7 -...
  • Page 8: Important Safety Advice

    ATTENTION : IN ORDER TO AVOID OVER HEATING DO NOT COVER THE HEATER Energy Retention Cells Energy retention cells are supplied separately to the radiator in packs of two. The reference number is 85743. Duo300n Duo400n Duo500n 8 Cells (4 Packs)
  • Page 9: Installation Of The Radiator

    INSTALLATION OF THE RADIATOR ASSEMBLY Ensure the electronic components are not damaged 1. Open carton from the bottom. Remove feet and when removing the panel. Carefully place the panel to one side. accessories bag from the polystyrene packaging. (Fig. 1) Check that the mains supply cables are not damaged.
  • Page 10 Panelled internal walls DO NOT USE 30MM SPACER ON INSIDE OF RADIATOR. If possible, locate the studding and use No. 10 size USE ONLY EXTERNALLY - SEE FIG. 11 woodscrews. Where it is not possible to locate the studding use type M5 Rawlplug INTERSETS on securely fastened plasterboard panelling.
  • Page 11 Fig. 18 , which will in accordance with the IEE regulations. prevent appliance settings being altered. For further details of connection to Dimplex programming devices, please refer to the relevant Dimplex programmer instructions. REASSEMBLY...
  • Page 12 CHECK PROCEDURE FOR INSTALLERS FOLLOWING INSTALLATION THIS CHECK PROCEDURE SHOULD BE CARRIED OUR BY A COMPETENT INSTALLER ONLY. THE OPERATING INSTRUCTIONS ARE AVAILABLE FOR END USERS. DuoHeat has a built in self diagnostic function that enables To check the radiant panel operation (comfort both service engineers and end users to diagnose faults.