V
SRX240 Services Gateway
Use the instructions in this guide to help you connect the SRX240 Services Gateway to your network. For details, see the SRX240
Services Gateway Hardware Guide at http://www.juniper.net/techpubs/a058.html.
SRX240 Services Gateway (Low Memory and High Memory)
SRX240 Services Gateway with Integrated Convergence Services (Back Panel)
The following four types of SRX240 Services Gateways are available:
Devices
SRX240B
SRX240H
SRX240H-POE
SRX240-P-MGW
PART 1 - CONNECTING AND CONFIGURING THE DEVICE
Use the instructions below to connect and set up the SRX210 Services Gateway to protect your network. Refer to the LEDs on the
front panel of the device to help you determine the status of the device.
Step 1
Connect the power cable to the device and a power source. We
recommend using a surge protector. Note the following indications:
•
Power LED (solid green): The device is receiving power.
•
Status LED (solid green): The device is operating normally.
Note: You must allow the services gateway between five and seven minutes
to boot up after you have powered it on. Wait until the Status LED is solid
green before proceeding to the next step.
Step 2
Connect the management device to the services gateway using either of
the following methods:
•
Connect an Ethernet cable from any one port between ge-0/0/1 and
ge-0/0/15 to the Ethernet port on the management device (workstation
or laptop).
We recommend this connection method. If you are using this method to
connect, proceed with Step 3.
•
Connect an RJ-45 cable from the console port to the supplied DB-9
adapter, which then connects to the serial port on the management
device. (Serial port settings: 9600 8-N-1-N).
If you are using this method to connect, proceed with the CLI
configuration instructions available in the Quickstart Guide for Branch
SRX Series Services Gateways at
http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf.
Step 3
Ensure that the management device acquires an IP address on the
DDR Memory PoE
512 MB
No
1 GB
No
1 GB
Yes
1 GB
Yes
SRX240 Services Gateway with Power over Ethernet
and with Integrated Convergence Services
Voice Support
Note: On the SRX240H-PoE and SRX240-P-MGW
models, Power over Ethernet (PoE) of 150 watts is
No
supported across all 16 ports (ge-0/0/0 to ge-0/0/15).
No
No
Yes
192.168.1/24 subnetwork (other than 192.168.1.1) from the device.
The interfaces have the following factory-default settings:
Interface
ge-0/0/0
ge-0/0/1 to ge-0/
0/15
Note:
•
The services gateway functions as a DHCP server and will assign an IP
address to the management device.
•
If an IP address is not assigned to the management device, manually
configure an IP address in the 192.168.1.0/24 subnetwork. Do not
assign the 192.168.1.1 IP address to the management device, as this IP
address is assigned to the device. By default, the DHCP server is
enabled on the L3 VLAN interface, (IRB) vlan.0 (ports ge-0/0/1 to ge-0/
0/15), which is configured with an IP address of 192.168.1.1/24.
•
When an SRX240 Series Services Gateway is powered on for the first
time, it boots using the factory default configuration.
Step 4
Access the J-Web interface:
1.
Launch a Web browser from the management device.
2.
Enter 192.168.1.1 in the URL address field.
3.
Specify the default username as root. Do not enter any value in the
Password field.
Getting Started Guide
Security Zone
DHCP State
untrust
client
trust
server
IP Address
unassigned
192.168.1.1/24
Need help?
Do you have a question about the SRX240 Series and is the answer not in the manual?
Questions and answers