TABLE 8
TEMPERATURE PRESSURE CHART
TEMP
R-410A
(Deg. F)
PSIG
-150
-140
-130
-120
-110
-100
-90
-80
-70
-60
-50
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
107.5
40
118.5
45
130.2
50
142.7
55
156.0
60
170.1
65
185.1
70
201.0
75
217.8
80
235.6
85
254.5
90
274.3
95
295.3
100
317.4
105
340.6
110
365.1
115
390.9
120
418.0
125
446.5
130
476.5
135
508.0
140
541.2
145
576.0
150
612.8
50
18.8 Subcooling Calculation
1. Measure the liquid pressure at the liquid line service valve.
2. Convert the liquid line pressure to saturated temperature. See Table 8.
3. Measure the liquid line temperature at the liquid line service valve.
—
4. Compare the liquid line temperature to the saturated temperature.
—
5. The difference between saturated temperature and liquid line temperature is the
—
subcooling. Subcooling normal range 9° to 12°.
—
—
—
—
—
—
0.4
5.1
10.9
14.2
17.9
22.0
TABLE 9
26.4
AIR CONDITIONING SYSTEM TROUBLESHOOTING TIPS
31.3
36.5
42.2
SYSTEM PROBLEM
48.4
55.1
62.4
Liquid Restriction (Drier)
70.2
Low Evaporator Airflow
78.5
Dirty Heat Pump
87.5
Low Outside Ambient Temperature
97.2
Inefficient Compressor
TXV Feeler Bulb Charge Lost
Poorly Insulated Sensing Bulb
AIR CONDITIONING SYSTEM
TROUBLESHOOTING TIPS
DISCHARGE
PRESSURE PRESSURE
Overcharge
High
Undercharge
Low
Low
Low
High
Low
Low
Low
High
INDICATORS
SUCTION
SUPERHEAT SUBCOOLING
High
Low
High
Low
High
Low
Low
High
High
Low
Low
Low
High
Low
Low
Low
High
High
High
High
High
Low
High
High
High
Low
Low
COMPRESSOR
AMPS
High
Low
Low
Low
High
Low
Low
Low
High
Need help?
Do you have a question about the R-410A and is the answer not in the manual?
Questions and answers